Search:

Type: Posts; User: lunchbox

Page 1 of 3 1 2 3

Search: Search took 0.01 seconds.

  1. try this one

    try this one
  2. Replies
    11
    Views
    1,149

    I would definitely go straight LON to the devices...

    I would definitely go straight LON to the devices if you are needing more than just a few crucial points in the Ax. We had a site that the BCU would crash every day due to the % processor idle time...
  3. Replies
    1
    Views
    628

    I don't think it can do both simultaneously. You...

    I don't think it can do both simultaneously. You have to choose the communication interface in the TU setup of the chiller, so I think the LON card can be installed and you can still communicate...
  4. If you have Tracer Summit on your laptop you can...

    If you have Tracer Summit on your laptop you can remotely access the Tracer Summit. Assuming it is not a BMTS BCU and it has ethernet connectivity.
  5. The button is probably the one that says "Trane...

    The button is probably the one that says "Trane Network use only" That is for Trane Techs to renew their license to upgrade the techview to Kestrelview. Kestrelview has a few added features for Trane...
  6. The UPCM is a Comm4 device. If you have rover,...

    The UPCM is a Comm4 device. If you have rover, you can try and search the link with it and see what you can see. I don't think you can see the UPCM with Rover, but you should be able to see the UV...
  7. Replies
    3
    Views
    444

    You've got mail.

    You've got mail.
  8. Here is what I could come up with a quick search

    Here is what I could come up with a quick search
  9. Replies
    4
    Views
    682

    All the Trane binarys are a 2 part SNVT. they...

    All the Trane binarys are a 2 part SNVT. they require a true/false and also a %. You could write the % to 100 all the time and switch the binary on/off and it would accomplish the task.
  10. Replies
    22
    Views
    3,588

    My email address is in my profile :)

    My email address is in my profile :)
  11. Replies
    22
    Views
    3,588

    Sent to you too :)

    Sent to you too :)
  12. Replies
    22
    Views
    3,588

    coming to you!

    coming to you!
  13. Replies
    22
    Views
    3,588

    Send me your email. I can get you the Range and...

    Send me your email. I can get you the Range and offset calculator and any IOMs you need
  14. You are correct. I wasn't thinking about the...

    You are correct. I wasn't thinking about the difference in static tubes and pitot tubes. I have both and use the static tip if I only need static pressure.
  15. I would use the pitot tubes to take the...

    I would use the pitot tubes to take the measurements with. If you insert a tube into the duct, you can get different readings when the tube is in different positions due to the velocity pressure of...
  16. Replies
    0
    Views
    494

    Trane VV551 integration with JACE

    I have a job that has 18 generic VAV boxes with the Trane VV551 VAV retrofit controllers. We used a 3rd party to integrate them into the JACE that is installed on the campus of my customer. The...
  17. Replies
    13
    Views
    1,585

    I was just talking to one of my co workers this...

    I was just talking to one of my co workers this morning about that. He said the valves have been redesigned and the replacement won't work with the old chiller module that controls the...
  18. Replies
    2
    Views
    1,611

    Try BAS-SVX17B-EN. I can e-mail it to you if you...

    Try BAS-SVX17B-EN.
    I can e-mail it to you if you can't find it. That may be the one you are looking for.
  19. Replies
    7
    Views
    1,051

    If the sensors are out of calibration, just...

    If the sensors are out of calibration, just replace them. They cost about $10 each. that is way less than the cost of the Rover service tool.
  20. Replies
    3
    Views
    544

    What is wrong with it?

    What is wrong with it?
  21. Replies
    2
    Views
    995

    There are configurations and programs that will...

    There are configurations and programs that will have to be downloaded into the new PCM. You will also need the program to set it up. If you happen to have copies of the old programs, you are good. If...
  22. Replies
    3
    Views
    891

    Go into the setup menu and enable tracer control....

    Go into the setup menu and enable tracer control. then you should be able to select tracer as a setpoint source.
  23. Replies
    18
    Views
    1,156

    I did some searching, and cannot find where It...

    I did some searching, and cannot find where It was mentioned. I'm sorry I thought I had posted a reply.
    If time permits, I'll make a couple calls today and inquire about it to some of the guys that...
  24. Replies
    18
    Views
    1,156

    I think it can be done, but that is a lot of...

    I think it can be done, but that is a lot of work. I will check around today and see if I can find some service bulletin or something like that that mentions the 580 being seen as a GLD.
  25. Replies
    18
    Views
    1,156

    I can't see any newer revisions of V15 SP1 on the...

    I can't see any newer revisions of V15 SP1 on the website. It seems like one version of summit brought in the MP580/581s in as a GLD.
    Have you tried reverting the firmware in the 580 to an earlier...
  26. Replies
    6
    Views
    1,299

    OA sensor is behind the mist eliminators /...

    OA sensor is behind the mist eliminators / louvers at the back of the rtu in the outside air intake section. Evap sensor should be mounted to the suction line in the location sgraefe said.
  27. Replies
    2
    Views
    589

    Are you looking to run your own business or get...

    Are you looking to run your own business or get hired by a "local" contractor? We have a large contract at Ft. Benning and need additional men. Most of it is chillers, cooling towers, and a few...
  28. Replies
    3
    Views
    384

    You're welcome. :)

    You're welcome. :)
  29. Thread: TRane TXV

    by lunchbox
    Replies
    8
    Views
    1,537

    Welcome! Good luck finding the issue.

    Welcome! Good luck finding the issue.
  30. Thread: Fan Status

    by lunchbox
    Replies
    17
    Views
    1,586

    I use a combination of a DP airflow switch and an...

    I use a combination of a DP airflow switch and an Adjustable CT. When setting up the drive, I adjust the CT to pull in when the VFD reaches the current the motor is pulling when at minimum frequency....
  31. Replies
    3
    Views
    384

    Check your e-mail

    Check your e-mail
  32. Thread: TRane TXV

    by lunchbox
    Replies
    8
    Views
    1,537

    Here are some service manuals.Hopefully they will...

    Here are some service manuals.Hopefully they will help
  33. Replies
    7
    Views
    1,204

    Sounds good. I will make my plans accordingly....

    Sounds good. I will make my plans accordingly. Thanks for the input!
  34. Replies
    7
    Views
    1,204

    I think most of the configuration / programming...

    I think most of the configuration / programming would be done locally at the controllers. Any time I get a large link, the upload / download times get to be so long that it is frustrating so I go to...
  35. Replies
    7
    Views
    1,204

    Wireless LON communication

    I have a job I have been looking at doing a controls retrofit on, and due to the size of the site, and the difficulty in running a new comm link I have been debating on using a wireless LON...
  36. Replies
    99
    Views
    13,689

    In recent memory, I almost caused the complete...

    In recent memory, I almost caused the complete destruction of a 60 ton Trane Recip. compressor.
    I was assisting one of our other less "experienced" techs doing some leak repairs on the compressor....
  37. Replies
    20
    Views
    2,328

    It should have had complete diagrams sent with...

    It should have had complete diagrams sent with it. However, if it was a Special order unit, they may not have had correct diagrams to send with it. If you still need info, I can try and get it for...
  38. Just a FYI. *disclaimer*I work for Trane...

    Just a FYI. *disclaimer*I work for Trane commercial, and in some respects, they handle the commercial side different from the Residential side.
    That being said, here are a few points I think need...
  39. Replies
    8
    Views
    579

    And the same book for the reliatel controller is...

    And the same book for the reliatel controller is a must have too. I don't work on either of these without the book in my bag.
  40. Replies
    10
    Views
    959

    I've seen the damage a spinning R/C plane prop...

    I've seen the damage a spinning R/C plane prop will do. I don't want to think about anything worse than that. I still shudder any time I think about the incident.
  41. Replies
    10
    Views
    959

    Ok. I haven't really been keeping tabs on the...

    Ok.
    I haven't really been keeping tabs on the latest news since Saturday. I have a friend who was out there about 30 yds from where it went in, and he said it was the most horrible thing he has...
  42. Replies
    8
    Views
    579

    Good luck with that one. rentals are the worst....

    Good luck with that one. rentals are the worst. Just like rental cars. they get terribly abused.
  43. Replies
    10
    Views
    959

    I had heard rumors of the trim tab failing and...

    I had heard rumors of the trim tab failing and the resulting roll / altitude change caused a 10+G blackout.
    Has there been any more discussion of that possibility?
  44. Replies
    1
    Views
    1,052

    This is a copy / paste from a Carrier 33CS manual...

    This is a copy / paste from a Carrier 33CS manual I have. None of what I have lists any values for checking the sensor out. It is all I have to use to check out the few VVT systems I work on.
  45. Replies
    6
    Views
    1,045

    I don't have visio experience, but you are...

    I don't have visio experience, but you are totally correct about autocad being difficult if you have no experience. It took me 2 years to teach myself enough to be proficient in it.
    That's what I...
  46. Replies
    42
    Views
    3,341

    I'm not an expert on split systems, but I think...

    I'm not an expert on split systems, but I think it may be due to a higher refrigerant charge and larger components in the 13 SEER system.
  47. Replies
    6
    Views
    1,045

    I use autocad LT, but found that autocad...

    I use autocad LT, but found that autocad freestyle is a decent program that does wiring schematics fairly easily.
    I use it to create simple graphics layouts, and edit existing graphics for retrofit...
  48. Replies
    5
    Views
    566

    I just thought of this, but does the compressor...

    I just thought of this, but does the compressor current (or the cavity pressure) stay steady when the load solenoid is not powered? It could be leaking by and causing the cavity to be pressurized to...
  49. Replies
    3
    Views
    1,421

    You're welcome. Glad to help.

    You're welcome. Glad to help.
  50. Replies
    3
    Views
    1,421

    Will this work?

    Will this work?
Results 1 to 50 of 105