  1. Replies
    53
    Views
    1,752

    I would think that a retired chiller tech who's...

    I would think that a retired chiller tech who's been a member of this board since '08 would be a pro member by now, not a regular guest. So I'm inclined to agree with you snupy.

    Also johncarlson,...
  2. Replies
    67
    Views
    2,619

    Just musing randomly, but breaking common would...

    Just musing randomly, but breaking common would still have power passing through all components prior to returning to the furnace/ahu. So possible damage to those components without a complete...
  3. Replies
    67
    Views
    2,619

    That's a good point beenthere; I'll remember that...

    That's a good point beenthere; I'll remember that for future reference since we're fellow PA-ns. ;)
  4. Replies
    53
    Views
    1,752

    Thanks to all of you for sticking up for me. I...

    Thanks to all of you for sticking up for me. I tend to read more than chime in since I have so little experience, hence why I don't post much. Still learning a lot from doing and also reading your...
  5. Replies
    53
    Views
    1,752

    So now that we finally cleared the air, was the...

    So now that we finally cleared the air, was the issue resolved/found?
  6. Replies
    67
    Views
    2,619

    A 90+% gas furnace would make condensate. ;) ...

    A 90+% gas furnace would make condensate. ;)

    I'd break Y as well unless the stat was digital and was hard wired with no batteries. People might notice a blank screen faster than no cooling. ;)
  7. Replies
    53
    Views
    1,752

    What? As was stated, I'm a two year tech. ME. I...

    What? As was stated, I'm a two year tech. ME. I was not making any slant at you or anyone else. Just trying to make a suggestion. So pardon me for trying to help based on MY limited experience. Was...
  8. Replies
    53
    Views
    1,752

    Glad to know someone else was thinking the same...

    Glad to know someone else was thinking the same thing. And thanks; HS teacher used to say it.


    Life is 10% what happens to you and 90% how you react.
  9. Replies
    53
    Views
    1,752

    Did you check all the safety limits? There may be...

    Did you check all the safety limits? There may be one on the blower that's open, causing the problem. You said the furnace lights though? Only a two year tech here. ;)


    Life is 10% what happens...
  10. Replies
    12
    Views
    477

    I saw it in a small catalog at UR. Said voice...

    I saw it in a small catalog at UR. Said voice command but then the product info said nothing about that feature. Counter guy said, "it's too f***ing hot!" or "damn, it's cold!" is how it works...
  11. Replies
    22
    Views
    885

    Phosgene is the result of heated refrigerant, and...

    Phosgene is the result of heated refrigerant, and you wouldn't be brazing with it in the lines. I'm not sure then what the other guy was talking about. If anything, you just need to be aware of oil...
  12. Replies
    94
    Views
    2,895

    Last I checked electricity was color blind. ;) ...

    Last I checked electricity was color blind. ;)


    Life is 10% what happens to you and 90% how you react.
  13. Replies
    26
    Views
    1,354

    Thanks! I'll keep that in mind.

    Thanks! I'll keep that in mind.
  14. Replies
    26
    Views
    1,354

    I've never seen this formula before. Could you...

    I've never seen this formula before. Could you explain the rationale for it?
  15. X2 simple math will tell you that. Cylinder...

    X2 simple math will tell you that.
    Cylinder volume = pi * r^2 * height
  16. Replies
    25
    Views
    1,133

    I didn't see it in any pictures, but was the...

    I didn't see it in any pictures, but was the float switch wired in correctly?
  17. Replies
    32
    Views
    1,426

    Stupid? Question about hoses

    My 410a gages have ball valve, but my 22 set is low loss. I like both.
    I too was under the impression that some kind of low loss hoses were required for service to lessen loss. Loosing all that...
  18. Replies
    65
    Views
    2,978

    Restriction at the distributor would be my guess....

    Restriction at the distributor would be my guess. Definitely a restriction though if it's freezing at that point.
  19. Replies
    63
    Views
    2,555

    I have two sets, one for 22 and another for 410a....

    I have two sets, one for 22 and another for 410a. That way I know I won't mix refrigerants.

    One thing an instructor told me about purging though is that if you purge and connect, the air in your...
  20. Replies
    34
    Views
    2,076

    When I used to take music lessons, my teacher...

    When I used to take music lessons, my teacher would always say, "Practice doesn't make perfect, perfect practice makes perfect." Meaning if you do something wrong repetitively, you'll keep doing it...
  21. Replies
    22
    Views
    1,586

    If you're using a SH calculator, you need outdoor...

    If you're using a SH calculator, you need outdoor ambient and indoor wet bulb to properly charge via SH. Your target might be 10 in 90 degree weather, but might only be 6 if it's 70 outside and dry...
  22. Replies
    22
    Views
    1,586

    He's talking about doing PMs on units, not...

    He's talking about doing PMs on units, not running ac for cooling comfort.
  23. Replies
    15
    Views
    739

    Frosted Coil

    I'd say outdoor temp. Forty-five degrees outside is in no way a good indicator of cooling. If anything, your saturation temp was around 70 outside, so having such a low temp there would surely have...
  24. Replies
    21
    Views
    819

    If the outdoor is also 2.5, you could run into...

    If the outdoor is also 2.5, you could run into problems just changing the AH. Too much refer in the evaporator. The EPR and HGBP would help mimic the proper BTU rating.
  25. Replies
    9
    Views
    534

    I'd use the piston that came with the condenser....

    I'd use the piston that came with the condenser. Even on new installs the evaporator piston doesn't match what came with the condenser all the time.