Search:
Type: Posts; User: Aiken Colon
Search: Search took 0.01 seconds.
-
09-22-2009, 05:32 PM
- Replies
- 63
- Views
- 2,670
From what I have seen on other trade boards,...
From what I have seen on other trade boards, people are really complaining about the Klein 11 in 1 lately. It is kind of shocking to me, because it was by far and away the most used and loved multi...
-
09-22-2009, 02:44 PM
- Replies
- 63
- Views
- 2,670
Wiha makes the best screwdrivers in the world,...
Wiha makes the best screwdrivers in the world, IMO.
JJ -
09-22-2009, 02:23 PM
Thread: question from another board
by Aiken Colon- Replies
- 3
- Views
- 360
Sorry. Here was the question. Do we have any...
Sorry. Here was the question.
Do we have any HVAC guys out there turned energy auditors? My interest is the similarity of our heat loss calculations versus a heating contractor doing a manual j... -
09-22-2009, 11:19 AM
Thread: question from another board
by Aiken Colon- Replies
- 3
- Views
- 360
question from another board
This is a question from another board that is more directed for members here.
JJ -
07-22-2009, 09:56 AM
- Replies
- 0
- Views
- 1,128
Fluke Infrared / Building Analyst Seminar - August 2009
Hey guys, AC Tool Supply is sponsoring a Fluke Infrared Building Analyst Seminar in Tempe, AZ on August 4, 2009. I thought this board would be a good place to post this because we are getting...
-
05-14-2009, 09:02 PM
- Replies
- 42
- Views
- 2,157
The Testo 435 is one sick meter. JJ
The Testo 435 is one sick meter.
JJ -
05-13-2009, 12:43 PM
- Replies
- 25
- Views
- 1,167
I agree 100% with you. Even when looking at a...
I agree 100% with you. Even when looking at a blackbody most IR thermometers are off +/- 5%. It is a very over marketed tool. There are times though that distance does force the use of one. Other...
-
05-13-2009, 10:53 AM
Thread: thermal imagery
by Aiken Colon- Replies
- 17
- Views
- 985
Fluke is USA made. FLIR is USA and Sweden. ...
Fluke is USA made. FLIR is USA and Sweden. Testo-Germany. Mikron-Japan.
Those are the major players in infrared. All of which have USA distribution and service. Fluke / FLIR are the two best... -
05-12-2009, 08:19 PM
Thread: thermal imagery
by Aiken Colon- Replies
- 17
- Views
- 985
Which camera is that? And why? Raz-IR is a...
Which camera is that? And why?
Raz-IR is a chinese camera. I believe SLP infrared is the US distributor, you could have major problems with service if that comes up. Having it serviced overseas... -
05-12-2009, 08:07 PM
Thread: Fluke 902
by Aiken Colon- Replies
- 39
- Views
- 1,994
Fluke bought Amprobe, and since then some of the...
Fluke bought Amprobe, and since then some of the meters have become an import. I am guessing because the Amprobe line had more manufacturing for those lines.
Most of Fluke's core line is still... -
05-12-2009, 08:01 PM
- Replies
- 25
- Views
- 1,167
Black electrical tape is approx .97 emissivity. ...
Black electrical tape is approx .97 emissivity. Personally I like the Fluke's and Testo's.
JJ
Energy Auditor & Weatherization Talk -
04-24-2009, 03:04 PM
Thread: HVAC unit temps
by Aiken Colon- Replies
- 9
- Views
- 291
Awesome, thanks. So my 212 degree camera is...
Awesome, thanks. So my 212 degree camera is going to be fine on almost all units based on that refrigerant information.
JJ -
04-24-2009, 01:46 PM
Thread: HVAC unit temps
by Aiken Colon- Replies
- 9
- Views
- 291
So if it is 100 outside the unit itself will only...
So if it is 100 outside the unit itself will only get up to 105 to 108 degrees, while the exhausted air will be 115 to 130? Is that for an average residential unit?
Thanks -
04-24-2009, 01:13 PM
Thread: HVAC unit temps
by Aiken Colon- Replies
- 9
- Views
- 291
Temps
I was not looking for the temperatures that are produced within the building or structure, but the heat the unit generates and radiates off. The unit, whatever it is called, where the compressor is...
-
04-24-2009, 12:20 PM
Thread: HVAC unit temps
by Aiken Colon- Replies
- 9
- Views
- 291
HVAC unit temps
What kind of temps do AC units run at? I am looking for max out put temps for residential, commercial and industrial units.
thanks in advance -
02-18-2009, 10:12 AM
Thread: Fluke i400 AC Clamp
by Aiken Colon- Replies
- 7
- Views
- 734
The 289 is amazing. If you purchase one make...
The 289 is amazing. If you purchase one make sure you are getting the whole 289 FVF kit. A lot of distributors are advertising them on the web as the 289, but fail to mention you are not getting...
-
02-18-2009, 10:09 AM
Thread: Ideal 700 Series
by Aiken Colon- Replies
- 4
- Views
- 378
With the exception of wire nuts and other misc...
With the exception of wire nuts and other misc wire connectors Ideal private labels almost everything. The benefit to it is that Ideal stands behind their stuff as good or better than every other...
-
02-17-2009, 03:22 PM
Thread: Extech
by Aiken Colon- Replies
- 54
- Views
- 3,612
It got implimented once the FLIR deal went...
It got implimented once the FLIR deal went through. Which was late last year. Some distributors are not adhering to it, and they are getting dropped because of it. So if you shop around you might...
-
02-16-2009, 10:06 PM
Thread: MyFlukeStore.com ?
by Aiken Colon- Replies
- 6
- Views
- 635
Gotta keep searching brother. Amazon charges...
Gotta keep searching brother. Amazon charges distributors 15% of the sale to move their goods. So generally Amazon a little bit more expensive than the best prices.
JJ -
02-16-2009, 10:04 PM
Thread: Extech
by Aiken Colon- Replies
- 54
- Views
- 3,612
Extech EX623
All Extech products are under what is called MMAP pricing. Manufactures Minimum advertised price. Meaning that distributors can only advertise one price. That is why you find the FLIR cameras (owns...
-
01-15-2009, 11:36 PM
Thread: Converted to fluke
by Aiken Colon- Replies
- 116
- Views
- 3,734
No temp (let alone dual type k's) or IR...
No temp (let alone dual type k's) or IR thermometer on the Ideal. Both kind of nice features for you guys.
JJ -
01-15-2009, 11:34 PM
Thread: Converted to fluke
by Aiken Colon- Replies
- 116
- Views
- 3,734
Oh yeah the tight site ones, I had two displays...
Oh yeah the tight site ones, I had two displays on the front in my mind when you originally posted that. Forgot about the ones that have the display in the bottom.
When those things first came... -
01-15-2009, 11:01 PM
Thread: Converted to fluke
by Aiken Colon- Replies
- 116
- Views
- 3,734
What I like about that whole series of temp...
What I like about that whole series of temp meters is its size. You know they could of made that thing a heck of a lot smaller, but they didn't. Sometimes, at least to me, smaller isn't always...
-
01-15-2009, 10:53 PM
Thread: Converted to fluke
by Aiken Colon- Replies
- 116
- Views
- 3,734
Which Ideal one has two displays? Never seen one...
Which Ideal one has two displays? Never seen one like that. Only thing I can think of is the 61-495. It is a single display but can display more than one thing in that display. Basically an...
-
01-15-2009, 10:45 PM
Thread: Converted to fluke
by Aiken Colon- Replies
- 116
- Views
- 3,734
yeah and I actually posted the wrong ohms for...
yeah and I actually posted the wrong ohms for those two anyway, getting late. 30 ohms for continuity. 6000 ohms for the 337 and the 355 is 400kΩ.
JJ
Results 1 to 25 of 30

