Search:

Type: Posts; User: mlc1955

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    13
    Views
    1,045

    I would go with the XV20 also, I one of the mid...

    I would go with the XV20 also, I one of the mid 80`s models (XV15 back then) and the outdoor unit is still pumping away. The indoor unit was replaced about 5 years ago due to a leak in the evaporator...
  2. Replies
    2
    Views
    280

    I have checked on the stat we have at our office...

    I have checked on the stat we have at our office and called our Trane tech guy and we do not see a way to make the screen dark other than what seems you have already done by making a black screen...
  3. Replies
    1
    Views
    287

    Trane uses Zwave technology in the thermostats...

    Trane uses Zwave technology in the thermostats they provide and opperates through the Nexia Home Intelligence service. They have a new stat, the 624 that is a really nice one at a good price.
    You...
  4. Replies
    3
    Views
    748

    Nest and variable speed

    We installed three Trane 16i 2 speed systems and the owner of the new home owner provided us with the Nest thermostats he wanted to use and they have been running good but we had one system start...
  5. Replies
    11
    Views
    893

    Yes I knew the mini port was text only but he...

    Yes I knew the mini port was text only but he wanted to see if the ip address that is labeled on the panel was correct. We have the ip listed but still it wont connect, am wandering if the windows 7...
  6. Replies
    11
    Views
    893

    Okay, new delimma, I`ve gotten several different...

    Okay, new delimma, I`ve gotten several different connectors. We have tried the usb to 9 pin to rj12 cable to the summit board and it would not connect. Then a friend said he uses an ethernet cable...
  7. Replies
    11
    Views
    893

    Thanks very much guy`s that puts me in the right...

    Thanks very much guy`s that puts me in the right direction so i`ll see what I can come up with.
  8. Replies
    11
    Views
    893

    I was told that windows 7 took a different usb...

    I was told that windows 7 took a different usb connecter butt my contact is out of town and no oneelse seems to know that. Even a computer guy told me that different items you are trying to connect ...
  9. Replies
    3
    Views
    367

    Clunks in the outdoor unit could be animals...

    Clunks in the outdoor unit could be animals getting into the fan blades or you could have some hard starting issues in the fan or compressor.
    Best to have a tech come out and service the equipment...
  10. Replies
    11
    Views
    893

    Tracer Summit connection

    Hi guy`s, just a quick question: can someone tell me the proper USB connection I need to connect our laptop with windows 7 installed so we can access the summit system. I have the 9 pin to RJ12...
  11. Replies
    2
    Views
    412

    In a typical system set up you would have an air...

    In a typical system set up you would have an air handler which would sit on top of a plateform which would be sealed with a return air grille that allows the air to inter the system and your fiter...
  12. Replies
    5
    Views
    540

    Honeywell PRO 6000 is battery operated and...

    Honeywell PRO 6000 is battery operated and programmable. You have an installers guide that you will have to be able to understand what type system you have and how to configure it to operate your...
  13. Thread: Brand???

    by mlc1955
    Replies
    7
    Views
    870

    is luxaire v/s model # for the blower. To get...

    is luxaire v/s model # for the blower. To get tonnage you need to get the model # of the coil that is installed.
  14. Replies
    2
    Views
    386

    Sounds like there may be freon issues, will need...

    Sounds like there may be freon issues, will need to have system serviced.
  15. You are not styck with the contractor, even if...

    You are not styck with the contractor, even if you have a 10 year parts and labor warranty you can still use another Trane deater for warranty issues. And I also am well pleased with the reliability...
  16. Replies
    10
    Views
    819

    What mode of operation are you asking for, cool...

    What mode of operation are you asking for, cool or heat and are these heat pump systems. If you are asking for the system to cool in the cooler weather this could drive the suction pressure down...
  17. Replies
    7
    Views
    582

    Whatever beand you use if you are concerned about...

    Whatever beand you use if you are concerned about power consumption then the higher the SEER rating the les the power useage. Bear in mind the higher the SEER rating the higher the cost. Stick to...
  18. You said the thermostat was on emergency heat...

    You said the thermostat was on emergency heat which will also prevent the outdoor unit from coming on. It should be in the heat mode to operate properly, the auxilary heat may not be big enough to...
  19. Sticky: Good to have you guys here. We all need advise...

    Good to have you guys here. We all need advise from time to time so ask away and hope you can help us to.
  20. Replies
    15
    Views
    1,374

    I agree on looks like a crack. Normally heat...

    I agree on looks like a crack. Normally heat exchangers last quiet awhile but who s willing to take the chance of not waking up tomorrow?
  21. Replies
    20
    Views
    1,141

    #1, If you have a 2 speed system you should...

    #1, If you have a 2 speed system you should alresdy have a variable speed blower but that doesnt mean it will speed up or slow down to match how many zones are calling. It only means it will match...
  22. I am not familiar with the crestron stat but the...

    I am not familiar with the crestron stat but the xl20 is a communicating system so the stat has to be communicating and im sure you would want that to be a matching communicating stat for proper...
  23. Replies
    3
    Views
    572

    Do you have a serial #

    Do you have a serial #
  24. I`m not a big fan of zoneing, but if I were to do...

    I`m not a big fan of zoneing, but if I were to do that and had plenty of room to get the dampers and extra return air from basement in I beleive i would go with 2 stage equipment so that I could set...
  25. Thread: ok what is it?

    by mlc1955
    Replies
    17
    Views
    1,296

    I think I would rule out low airflow across the...

    I think I would rule out low airflow across the indoor coil because if that was driving the high up usually the suction would go up also. Generally a refrigerant flow restriction makes the head go go...