  1. Replies
    24
    Views
    872

    Use a large Magnet like the ones used to reset...

    Use a large Magnet like the ones used to reset smoke heads. Place on the side of the valve and slide It back and forth with the comp off and listen to see If you can hear the slide move Internally.
  2. Replies
    40
    Views
    2,799

    I don't usually have to work with other people...

    I don't usually have to work with other people but the times I have on weekend work with 14 hour days keeping track of your tools gets tough. That's why all my tools In my service bag are taped with...
  3. Replies
    22
    Views
    3,207

    I know this Is an old thread but can someone...

    I know this Is an old thread but can someone Email me the service bulletins you guys are talking about for the YCD units?
    I just finished cleaning up a 460v transformer mess on a YCD and found two...
  4. Replies
    9
    Views
    447

    You need to get a ESP reading for the unit then...

    You need to get a ESP reading for the unit then compare to the units fan chart. Once air flow Is confirmed to be ok or not then you can move on.
    Sounds like you need to quote for increased duct...
  5. Replies
    9
    Views
    447

    Total static as In ESP? Where does your .5 ESP...

    Total static as In ESP? Where does your .5 ESP land you on the fan chart for CFM?
    Does the system run long enough to get super heat and sub cool readings?
    Whats your suction pressure doing while...
  6. Replies
    10
    Views
    667

    If your changing your sheaves every 6 months,...

    If your changing your sheaves every 6 months, Then you have a serious misalignment going on. Sheaves aligned correctly should easily last 3-4 years.
  7. Replies
    4
    Views
    350

    Sending you an email right now. Thank you

    Sending you an email right now.
    Thank you
  8. Replies
    7
    Views
    565

    Incorrect TXV? You say It was converted from...

    Incorrect TXV?
    You say It was converted from R-12 back In the day to R-134A Correct me If Im wrong but would that mean the TXV needs to be changed also? You mention It looks original.

    No pump...
  9. Replies
    4
    Views
    350

    Sorry to get back to this thread so late. I got...

    Sorry to get back to this thread so late. I got slammed with a bunch of work and I totally forgot about this post. I'm looking to do an open and Inspect to see what condition the crank and rods are...
  10. Replies
    19
    Views
    1,119

    I've replaced dozens of Trane Intellipak...

    I've replaced dozens of Trane Intellipak compressors with Danfoss units from URI
    Change the comp, rebuild the TXV, Replace the core and away the unit goes. Never once had a problem with changing...
  11. Replies
    2
    Views
    453

    You would need to lock the blades In a fixed...

    You would need to lock the blades In a fixed position for starters. Also need to check your supply motors and make sure they are ready for Inverters ( Check the Insulation class on the name plate )...
  12. Replies
    4
    Views
    350

    Trane E Machine Rebuild Info requested

    So I just picked up a new account with a couple Trane E machines on the roof, Built up system with 6 TXV's. Hot gas runs Into a BAC tower.
    Basically doing a fine tooth rebuild and replace of...
  13. Replies
    22
    Views
    4,133

    Thats why we perform a shake down on all...

    Thats why we perform a shake down on all equipment before Its started. Its good practice and will save you the trouble later.
  14. This unit holds a pressure test for more then an...

    This unit holds a pressure test for more then an hour without dropping?
    I find It hard to believe you have that much moisture In the system when It was only open for a short time.

    +1 for the pan...
  15. Thread: Solenoid valve

    by 1SikLBZ
    Replies
    5
    Views
    426

    I like to use Belimo valves ...

    I like to use Belimo valves

    http://www.belimo.us/ishop/theme/node/10076.xml
  16. Replies
    9
    Views
    1,180

    Double post

    Double post
  17. Replies
    9
    Views
    1,180

    Why don't you just ring the units power to ground...

    Why don't you just ring the units power to ground then start unplugging electric components till it stops ringing?
    Its not that hard to trace out a grounded wire or motor.
  18. Replies
    22
    Views
    3,055

    Its hard to tell from the pic but Its only a...

    Its hard to tell from the pic but Its only a regular size breaker so It only touches one phase or leg of power. Its a twining breaker used to free up space In a panel when your looking to add more...
  19. Replies
    22
    Views
    3,055

    Lol no it has never worked. Its touch only one...

    Lol no it has never worked. Its touch only one Buss bar, 110v out of both sides of the breaker but not 220 because its not on A and B buss bars
  20. Replies
    22
    Views
    3,055

    Electricians are funny

    Co worker text me a pic of this earlier today, I got a kick out of it.
    Anyone see what they did?
  21. Replies
    9
    Views
    1,581

    I actually saw this same thing done for a server...

    I actually saw this same thing done for a server room the other day on a new building I picked up. I Informed the building owner and he replied with " It still keeps my server cool so why should I...
  22. Replies
    9
    Views
    1,721

    Yeah Its a sound that stands out of the normal...

    Yeah Its a sound that stands out of the normal lol

    An Electrician changed out a 3 phase breaker for a RTU on a building that I service, He didn't check his phasing and when I went out to perform...
  23. Replies
    17
    Views
    2,359

    It makes sense why a vent Is not needed, I was...

    It makes sense why a vent Is not needed, I was always told to Install one after the P Trap.
    I hate when I go to flush out a drain with a nitro blast I have to find some cleaver way of capping the...
  24. Replies
    17
    Views
    2,359

    Not a bad Idea. How come there Isn't a vent on...

    Not a bad Idea.
    How come there Isn't a vent on your trap tho?
  25. Replies
    12
    Views
    4,848

    I was going to ask, Then I read this. lol No...

    I was going to ask, Then I read this. lol

    No way to protect the 2 wire on the sensor?