Search:
Type: Posts; User: jemair
Search: Search took 0.21 seconds.
-
02-13-2005, 08:17 PM
Thread: Vogt ice machine
by jemair- Replies
- 14
- Views
- 3,026
Turbo is a maker of large commercial ice makers.I...
Turbo is a maker of large commercial ice makers.I service two 25 ton units and a 10 ton unit at one location.They make sheets (plates) of ice.
-
02-10-2005, 11:03 PM
Thread: Draught (draft) line cooling lines
by jemair- Replies
- 5
- Views
- 782
This set up will work.If your beer trunk consists...
This set up will work.If your beer trunk consists of two copper lines surrounded by the vinyl beer lines and wrapped in rubatex you have what we see here very often.The AEV is a constant pressure...
-
09-23-2004, 09:35 PM
Thread: styrofoam containers
by jemair- Replies
- 6
- Views
- 702
I already have this answer but I want you guys to...
I already have this answer but I want you guys to try it out.If you have take out salad (potato, macaroni) in a cooler, stored in a styrofoam container over night in the cooler and the cooler is at...
-
09-23-2004, 09:09 PM
Thread: Any one with a Funny Refrigeration Story
by jemair- Replies
- 91
- Views
- 9,877
Had a customer take my service van a few blocks...
Had a customer take my service van a few blocks away from his store and hid it on me. Last time I ever left my keys in a vehicle.
-
09-23-2004, 08:37 PM
Thread: leak sealant for refrigeration system?
by jemair- Replies
- 19
- Views
- 2,091
Leak testing is an art that belongs in our trade....
Leak testing is an art that belongs in our trade. Learn how to do it properly and put that leak seal crap with buddies 'Redtech' refrigerant.
-
09-22-2004, 10:44 PM
Thread: Should I have just done this MYSELF???
by jemair- Replies
- 38
- Views
- 6,893
To think that you paid this jerk-off any money is...
To think that you paid this jerk-off any money is insane. This guy is a licenced hack and should be reported before he screws anybody else.Sorry about your luck.
-
09-21-2004, 09:53 PM
Thread: big a$$ hot tub on deck
by jemair- Replies
- 16
- Views
- 1,289
Canadian water is 10 lbs per gallon, must be all...
Canadian water is 10 lbs per gallon, must be all that fish we got up here.
-
09-21-2004, 09:46 PM
Thread: how old is your grandma
by jemair- Replies
- 14
- Views
- 940
grandmothers are both dead. my mother happens to...
grandmothers are both dead. my mother happens to be 92 years old. Brought her to east coast of Canada this past August.
-
09-19-2004, 09:03 PM
Thread: Direct sell walk-in install
by jemair- Replies
- 8
- Views
- 715
I have done many installs for a company called...
I have done many installs for a company called Canadian Curtis Refrigeration. We do o.k on them and end up with all the customers after.
-
09-16-2004, 09:44 PM
Thread: ??Red Tek Help Questions??
by jemair- Replies
- 9
- Views
- 934
I think that stuff has a red dye in it. Get some...
I think that stuff has a red dye in it. Get some liquid out of the jug to see if it does then put the jug in the garage and forget you have it.
-
09-16-2004, 09:17 PM
Thread: Alco, made in Mexico! And proud of it?
by jemair- Replies
- 2
- Views
- 651
Sporlan forever!
Sporlan forever!
-
09-16-2004, 09:15 PM
Thread: Manitowoc, TXV Quick Help
by jemair- Replies
- 11
- Views
- 1,957
Order OEM valve from Manitowoc. I always try to...
Order OEM valve from Manitowoc. I always try to install original parts and then there is no second guessing the part.Why was the first one replaced?
-
09-14-2004, 06:28 PM
Thread: spark ignition systems
by jemair- Replies
- 17
- Views
- 1,418
As soon as pilot is lit with a steady flame...
As soon as pilot is lit with a steady flame touching the flame sensor then the main burners should light. Check for 24 volts between PVMV terminal and MV terminal on gas valve. If 24 volts is present...
-
09-04-2004, 10:34 PM
- Replies
- 12
- Views
- 1,048
If you are getting an amp draw on the...
If you are getting an amp draw on the compressor?, and your gauges are hooked up at the compressor then you either have a rotary compressor running backwards or a recip that is pooched.Not pumping...
-
09-04-2004, 10:18 PM
- Replies
- 13
- Views
- 1,107
air conditioning condenser fan cycle control set...
air conditioning condenser fan cycle control set to 270# cut in and 170# cut out . 100# differential.period. I live where night time ambient can get quite low and if fan cycle differential is too...
-
08-27-2004, 08:24 PM
Thread: i walked off today
by jemair- Replies
- 46
- Views
- 8,690
first off that is very unsafe, you would have to...
first off that is very unsafe, you would have to be crazy to climb it. If anyone doesn't think it is unsafe you're a moron. second, a monkey would be embarrassed to climb that junk. here $200.00...
-
08-05-2004, 04:59 PM
Thread: 3 phase compressor will not pump down
by jemair- Replies
- 16
- Views
- 1,670
If it has an oil separator the float in the...
If it has an oil separator the float in the separator is probably stuck open. I just replaced one with this problem only two weeks ago. At defrost pump down, compressor could only pull down to about...
-
07-23-2004, 10:35 PM
Thread: fusite terminal blow- up
by jemair- Replies
- 4
- Views
- 583
never replace blown fuses before you have...
never replace blown fuses before you have thoroughly tested for grounds and/or shorts,and then stand to one side when you turn that disconnect back on. That compressor must have been grounded and a...
-
07-03-2004, 10:03 PM
Thread: What a Jag Revisited!
by jemair- Replies
- 7
- Views
- 700
I have been self employed for 12 years. Worked...
I have been self employed for 12 years. Worked for a great company for 11 years prior to that. Starting my own business has been amazing, quality of life is way up there and I have told a few jerks...
-
07-03-2004, 09:45 PM
- Replies
- 21
- Views
- 1,386
R12 is right. Take the time to do the best you...
R12 is right. Take the time to do the best you can so your not wasting time doing a call back. We also have 1/3 and 1/4 HP condensing units in the shop ready to go.Saves some time on site. Remember...
-
06-17-2004, 06:07 PM
Thread: taylor freezers
by jemair- Replies
- 4
- Views
- 867
taylor freezer
customer switched product sides and problem is still on the left side. going there tomorrow to recover charge in case the R502 is crossed with R408 or some other unknown refrig from previous company....
-
06-16-2004, 09:45 PM
Thread: taylor freezers
by jemair- Replies
- 4
- Views
- 867
has anyone ever run across this type of problem....
has anyone ever run across this type of problem. Taylor model 339 soft serve machine, vanilla (left side) won't stand up, soft appearance. product temperature is 15 degrees, normal should be 18 to 20...
-
if the power element is broken (lost charge) the...
if the power element is broken (lost charge) the tx closes off, system will go into a vacuum and stay there. Must still know if a cpr is in the unit. If no cpr troubleshoot metering device, if there...
-
copeland compressor with low suction.
you are bound to find a cpr valve on that hussman that is not openning propely.
Results 1 to 24 of 25