    if the 1500 is not a major consideration, go with...

    if the 1500 is not a major consideration, go with trane coil. it is a better coil and anything ADP or aspen makes in my opinion.
  2. he is most likely using it for SEER and EER...

    he is most likely using it for SEER and EER ratings... but if he is installing a XV95 you will get a tax credit anyway. I would prefer the Trane coil.
  3. Well, I have been exposed to r410a since about...

    Well, I have been exposed to r410a since about year 2000 working for a carrier dealer. Both Trane and Carrier have stated in classes that I have personally sat in on that pipe replacement is not...
  4. Replies
    58
    Views
    5,460

    I would still be interested to find out if there...

    I would still be interested to find out if there was any dye in the outdoor unit somewhere. Did they even check? I personally don't have a big problem with dye, but Trane does not recommend it.
  5. Replies
    58
    Views
    5,460

    a .64 static is not as bad as I thought it would...

    a .64 static is not as bad as I thought it would be according to what you are describing. I would have probably put the trap closer to the unit as well. I would be interested to see the static...
  6. Replies
    14
    Views
    2,198

    that is freakin great!

    that is freakin great!
  7. Replies
    18
    Views
    2,136

    see that **** all of the time here in DFW! I try...

    see that **** all of the time here in DFW! I try to explain to customers and show them pictures of things like that and they still go with the cheap contractor. Sad thing is that I walk on 10 year...
  8. Thread: Plenum

    by a/c-harris
    Replies
    9
    Views
    1,853

    That is cost savings to the extreme. There is a...

    That is cost savings to the extreme. There is a big company here in Dallas that just places a 14 or 16" round flex duct on top of carrier air handlers and hooks it to a remove plenum in the attic. I...
  9. Replies
    6
    Views
    1,038

    unfortunetly you will see installs like that all...

    unfortunetly you will see installs like that all day long in DFW metroplex.
  10. Replies
    9
    Views
    1,026

    I think 12-13 is reasonable in a good economy. I...

    I think 12-13 is reasonable in a good economy. I do not know what you should expect in current conditions
  11. Replies
    20
    Views
    1,865

    I personally think that Trane is a better peice...

    I personally think that Trane is a better peice of equipment, however the install is the most important. Amana is a Goodman with a different nameplate as previously stated. They are playing the odds...
  12. Replies
    52
    Views
    8,050

    it is the ozone you are smelling. Trane has it...

    it is the ozone you are smelling. Trane has it where the dealer can adjust it for people who are sensitive to that smell. The unit will still work fine.
  13. Replies
    27
    Views
    3,727

    that is one cheap install. Have a r/a plenum...

    that is one cheap install. Have a r/a plenum added to fix return problems, and get rid of that allstyle coil. If you hire a decent contractor they can hook the ducts up a little better on a new...
  14. In dallas they have to be hung, and I would...

    In dallas they have to be hung, and I would suspect in houston it is the same. Whenever I see one sitting on stands in a attic it is usually a very old installation. Having it hung is usually...
  15. I would suspect that the one s/a duct right next...

    I would suspect that the one s/a duct right next to the coil will get poor cooling temps with all zomes open. Install does look good though.
  16. Replies
    20
    Views
    3,014

    is the noise keeping you up at night? I have a...

    is the noise keeping you up at night? I have a trane airhandler installed at my house and it makes the hammering noise when in heat mode and outdoor heatpump shuts down. I installed a magnet and it...
  17. you are being over paranoid. get a better filter,...

    you are being over paranoid. get a better filter, It probably wasnt mold anyway. I also think it would be extremely stupid to tell your insurance company. And as previously stated, not tech can just...
  18. Replies
    24
    Views
    5,019

    I personally think its a nice install and I wish...

    I personally think its a nice install and I wish Texas installs looked like this. Not a problem passing inspection here. If you people could only see what is acceptable ( in Texas), you would never...
  19. Replies
    5
    Views
    2,240

    whats really sad is that if the ducts were hung...

    whats really sad is that if the ducts were hung properly and sealed it would probably work a lot better. They would have been better putting a 13 seer 2 ton back on system and straightening out...
  20. Replies
    11
    Views
    1,187

    I have been told by both carrier and trane...

    I have been told by both carrier and trane factory reps that it is not necessary as long line sizes are correct. I was told they used to thnik the mineral oil and poe oil would gel when mixed...
  21. Replies
    43
    Views
    9,388

    that is so stupid, I question was this setup to...

    that is so stupid, I question was this setup to be a joke for the WOS.
  22. Replies
    21
    Views
    2,196

    This comment was directed at you and several...

    This comment was directed at you and several others (majority) on this site. So please dont feel like I am just picking on just you. I certainly would not want to bid a job for someone who has...
  23. Replies
    21
    Views
    2,196

    I love how everyone on this site immediatly jumps...

    I love how everyone on this site immediatly jumps on contractors when a customer asks us a question. I will admit their are a lot of hacks in this trade, but there is also a lot of individuals who...
  24. Replies
    1
    Views
    794

    I guess I dont qualify. haha. I tried to call you...

    I guess I dont qualify. haha. I tried to call you today but got voicemail, next time Ill leave a message.

    best wishes and happy holidays,
    Blake

    Also, I might know someone interested. Are you...
  25. Replies
    2
    Views
    839

    possible job change - want opinions

    Lets suppose a tech was getting burnt out at his current company and was offered a management job at a local supply house. This individual has plans to get a contractors license and wishes to do...
Results 1 to 25 of 230
Page 1 of 10 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event