Search:

Type: Posts; User: thirdcoast361

Page 1 of 5 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    33
    Views
    1,104

    Yeah I was gonna leave it off but you know those...

    Yeah I was gonna leave it off but you know those boss types like to be all bossy and ****
  2. Replies
    33
    Views
    1,104

    Nope thats what they shipped marked ah drip kit...

    Nope thats what they shipped marked ah drip kit and installed as per instructions. Cleaning the coil worked like a charm though I'm not to worried about that stupid thing
  3. Replies
    33
    Views
    1,104

    Tranes "drip eliminator" or glorified hail guard...

    Tranes "drip eliminator" or glorified hail guard whatever...
    510961
  4. Replies
    33
    Views
    1,104

    I stand corrected. Holy crap its like a night and...

    I stand corrected. Holy crap its like a night and day difference. A quick spray down with cal-spray no rinse and brush the coil down with a soft bristle brush and not one damn drop off the coil now...
  5. Replies
    33
    Views
    1,104

    Gonna give it a good cleaning tomorrow but I...

    Gonna give it a good cleaning tomorrow but I doubt it is residual oil being it has been running for almost a year. If all else fails I'll install the "drip eliminator" untill I can figure it out.
  6. Replies
    33
    Views
    1,104

    M#twe120e300ab let me see if I can post a vid we...

    M#twe120e300ab let me see if I can post a vid we are gonna clean it Monday but this unit has been running for a little less than a year I dont see how it could just now be factory oil
  7. Replies
    33
    Views
    1,104

    Negative pressure on the coil blower is up top

    Negative pressure on the coil blower is up top
  8. Replies
    33
    Views
    1,104

    Its a slant coil I'll try and post video when I...

    Its a slant coil I'll try and post video when I get home
  9. Replies
    33
    Views
    1,104

    No it drips when the system is running also it...

    No it drips when the system is running also it just does it really bad when it shuts down
  10. Replies
    33
    Views
    1,104

    The install manual says something about rotating...

    The install manual says something about rotating coils 4 degrees but not on 120 models only 125 or higher
  11. Replies
    33
    Views
    1,104

    Missing the pan completely all the way up and...

    Missing the pan completely all the way up and across the coil. I took some video ill see if I can upload in a bit. When you shut the system down it comes raining down. I spoke to someone with tech...
  12. Replies
    33
    Views
    1,104

    Its not being blown off its dropping. Looking at...

    Its not being blown off its dropping. Looking at it today the coils are intertwined I dont think staging is the issue. It has to be an airflow issue. Wierd thing is when I shut the system down the...
  13. Replies
    33
    Views
    1,104

    Condensate dripping off coil....

    Alright folks a few of our guys recently installed a 10 ton train vertical, will get model #s tomorrow if need be. They had the issue of condensate dripping off the evap before hitting the drain pan...
  14. Yeah I hate when the damn valve cores get stuck...

    Yeah I hate when the damn valve cores get stuck and its just dumping. I have the hoses with ball valves and I keep a pair of channel locks close when I disconnect, usually give the valve a whack or...
  15. Nice

    Nice
  16. I have changed out at least 4 in the past 3 weeks...

    I have changed out at least 4 in the past 3 weeks

    Sent from my SCH-R970C using Tapatalk
  17. I don't have any model numbers off hand, would...

    I don't have any model numbers off hand, would have to check paper work. The location is bottom of the coil where the discharge and suction pass under the coils.

    Sent from my SCH-R970C using...
  18. Trane condenser coil leak and temporary bypass?

    Howdy folks. lately we have had a ton of trane coils with leaks all in the same spot. I know they came up with a patch kit at one point but we dont use them anymore. One of our lead techs gave a...
  19. Replies
    11
    Views
    1,901

    She was the fix it as cheap as you can, can you...

    She was the fix it as cheap as you can, can you just replace the fins that were "chewed" off type. She gladly paid 300 bucks for a hard start and new run cap though.

    Sent from my SCH-R970C using...
  20. Replies
    11
    Views
    1,901

    She had 5 big ass dogs. Thats just one side of...

    She had 5 big ass dogs. Thats just one side of the coil it looks like that all the way around. She refused to let me get her a price on a new one.

    Sent from my SCH-R970C using Tapatalk
  21. Replies
    11
    Views
    1,901

    Looks more like dog piss to me, but she swore up...

    Looks more like dog piss to me, but she swore up and down they chew on it. I really wanted to throw my hands up and walk away from this one.

    Sent from my SCH-R970C using Tapatalk
  22. Replies
    11
    Views
    1,901

    Can I get one more summer?

    Got a call that condenser wasnt running and when she reset the breaker smoke and sparks were shooting out of the control box. When I got there I found two crispy gekos on top of the run cap and a...
  23. Eeee thats gonna leave a nice scar Sent from...

    Eeee thats gonna leave a nice scar

    Sent from my SCH-R970C using Tapatalk
  24. Replies
    4
    Views
    1,512

    Maintenance man fix

    Found this in a mech room. Rusted leaky flange on an overhead inline pump. I guess replacing it is not in the budget.487761
    487771
    Rigged up a 5 gal bucket and extended to a floor drain.

    Sent...
  25. That is awesome. I love it. Sent from my...

    That is awesome. I love it.

    Sent from my SCH-R970C using Tapatalk
Results 1 to 25 of 101
Page 1 of 5 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event