  1. Replies
    16
    Views
    959

    I've seen this before when an adjustable motor...

    I've seen this before when an adjustable motor sheave is opened to far. The belt hangs up in the sheave and pulls it off of its bracket.
  2. Replies
    9
    Views
    837

    Check out The Alignment Blog by Vibralign.

    Check out The Alignment Blog by Vibralign.
  3. Replies
    9
    Views
    1,140

    Step Plate Adapter Set SPX/PowerTeam P/N 8075 or...

    Step Plate Adapter Set SPX/PowerTeam P/N 8075 or 8076
  4. Replies
    7
    Views
    801

    Daikin doesn't recommend liquid line driers. Be...

    Daikin doesn't recommend liquid line driers. Be sure to purge if any brazing is required and pull a deep vacuum.
  5. Replies
    38
    Views
    6,095

    I saw the Hilmor gauges at the AHR EXPO in...

    I saw the Hilmor gauges at the AHR EXPO in Dallas. They looked cheap to me. I wasn't impressed.
  6. Replies
    18
    Views
    3,536

    Try the fluke 80pk-3a touch probe. I have several...

    Try the fluke 80pk-3a touch probe. I have several of the fluke temp clamps, but like the touch probe best.
  7. Yellow Jacket 19102 Quick Coupler 1/4" Fem QC x...

    Yellow Jacket 19102 Quick Coupler 1/4" Fem QC x 3/8" M Flare
  8. Replies
    11
    Views
    1,264

    We use Pully Partners to laser align them

    We use Pully Partners to laser align them
  9. Replies
    3
    Views
    762

    Its a WSHP. The drier is an 085S bi-flow the 5/8"...

    Its a WSHP. The drier is an 085S bi-flow the 5/8" copper that runs parallel with the drier is a straight shot through.
  10. Replies
    3
    Views
    762

    Parallelled Liquid Liquid Line Drier

    I rebuilt the TXV in Addison water cooled RTU today. The bi-flow liquid line driers were installed in parallell to the main liquid line from the factory. I cut the section out and expected to find a...
  11. Replies
    15
    Views
    2,041

    I recently had a couple LGA240's that I replaced...

    I recently had a couple LGA240's that I replaced 4 powerheads on one and 3 on the other. There are no screens on the Sporlan OEM vale. If you dont have a drop across the drier, its the valve.
  12. Thread: Work in Texas

    by bsullins
    Replies
    52
    Views
    6,381

    Dallas

    our operations manager was talking to me today about looking for a larger equipment tech. Voyagers, Intellipak's, AquaSnaps and the likes. Its a great company all commercial from 1 ton mini-mates to...
  13. Thread: Appion vs C&D

    by bsullins
    Replies
    95
    Views
    7,979

    I got on the appion wagon too after reading all...

    I got on the appion wagon too after reading all the good reviews. I have the same problem with my Appion CRT's, they will not pull a core. I also bought the 1/2" hoses w/ 3/8" x 1/4" fittings and the...
  14. Replies
    15
    Views
    933

    What are you pressures, SH, SC, and temp drop?

    What are you pressures, SH, SC, and temp drop?
Results 1 to 14 of 14