Search:

Type: Posts; User: anasmilbes

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    0
    Views
    65

    Emerson Einstein 2 & E2E

    Since ive started working on these E2s ive been wiring Networks cables (cat5) from E2 to store network server. But, Ive ran into a problem at one store which im having trouble with. Mangment does not...
  2. Replies
    22
    Views
    1,422

    When i was a kid my Dad told me if you put the...

    When i was a kid my Dad told me if you put the same thing back from were you got every time, you will never lose a thing!......Til this day, it stands true
  3. Replies
    10
    Views
    411

    Looks like youve been spellnotized

    Looks like youve been spellnotized
  4. Replies
    58
    Views
    3,493

    If it makes you feel better, Im on call 7days a...

    If it makes you feel better, Im on call 7days a week with no bonus or incentive pay. I knew what i was getting into when i signed up
  5. Replies
    72
    Views
    2,024

    Sight glass, Subcooling, superheat,...

    Sight glass, Subcooling, superheat, Weight.........take your pick
  6. Replies
    28
    Views
    750

    R-22, 407c, 404a, 134, 410, MO99............Why...

    R-22, 407c, 404a, 134, 410, MO99............Why couldn't they invent one Refrigerant that's used for everything!!!!!
  7. Replies
    2
    Views
    137

    Since I joined on ive requested that I handle all...

    Since I joined on ive requested that I handle all expenses on a seprate account for hvac/r to know what we're spending down to the dime. Yet they still havent changed that. All maintenance is on one...
  8. Ive heard that if you have an EPR on a circuit...

    Ive heard that if you have an EPR on a circuit keeping constant temp say 35, with little to no fluctuations then you don't ever need off time. Not willing to test on my own time. Maybe your buddy...
  9. Replies
    2
    Views
    137

    Does your company appreciate you?

    Ive been working at a company as an inhouse tech for little less than 3 years now. My duties include all Hvac/R service, installation and maintenance. I serve 8 stores within a 70 mile range. Now,...
  10. Replies
    49
    Views
    1,193

    Any guy that speaks so highly of himself is BS....

    Any guy that speaks so highly of himself is BS. Look for a humble guy. Less headaches. Also, go get your universal 608 and ask contractor's if you can work for free or as a helper. Where are you...
  11. Im from California and we have lots of these...

    Im from California and we have lots of these controllers here
  12. I took out a 8 defrost timers and an old pressure...

    I took out a 8 defrost timers and an old pressure controller. I use the Einstein 2 by CPC to control Everything
  13. Side note- Have not had a service call since...

    Side note- Have not had a service call since install
  14. First CPC 88 Board Install. Less than 3 years experience in the HVAC/R field

    3 Years ago, i didn't know the difference between a condenser or an evaporator. I was going into this field with zero skills. I didn't even know the difference between a hot or neutral wire. Now,...
  15. How do I check dewpoint? No honeycomb filters...

    How do I check dewpoint?

    No honeycomb filters and cleaned honeycombs.

    Will check velocities also.

    Aj Milbes
  16. Washed case from top to bottom. Cleared drains...

    Washed case from top to bottom. Cleared drains and good as new.

    Aj Milbes
  17. Condensation on kysor warren multideck case

    Second post about this case.

    Humidity instore is around 48-52 percent
    Case setpoint 29
    Fans are exact for case model. Blades are exact also.

    Case next to it doesn't have any condensation,...
  18. Replies
    4
    Views
    322

    This is the Ask Our Pro's forum. In order to post...

    This is the Ask Our Pro's forum. In order to post a response here, you must have verified qualifications and have been approved by the AOP Committee. You may ask a question by starting a new thread....
  19. I've retrofitted many systems. Usually the valves...

    I've retrofitted many systems. Usually the valves were balanced ports and worked just fine. Havent had any problms yet. I will look into that. Thanks

    Sent from my SGH-T999 using Tapatalk 2
  20. Replies
    12
    Views
    702

    United refrigeration usually have counter charts

    United refrigeration usually have counter charts
  21. For starters, any route you go you need to change...

    For starters, any route you go you need to change the power heads on the evaps. I think sporlan 404a power heads are sc43 or sc53 for medium temp and sz 43 or sz53 for low temp.

    Outdoor unit;...
  22. Replies
    11
    Views
    773

    I hate those damn things. And yes. They do

    I hate those damn things. And yes. They do
  23. I've been in the field about 2 years now in...

    I've been in the field about 2 years now in commercial refrigeration. I have the Sman2 which has a built in micron gauge and made it a habit to use. I evacuate to at least 800microns to be safe....
  24. Replies
    13
    Views
    2,023

    Sorry guys. Ive been caught up past couple days....

    Sorry guys. Ive been caught up past couple days. But wow, very useful info has been posted since I last checked. So il try and test your recommendations. Your input is highly appreciated.

    Thanks...
  25. Replies
    13
    Views
    2,023

    Okay. Now if I cannot find specs on a case...

    Okay. Now if I cannot find specs on a case becasue its too old or something, is there a rule of thumb or no?
Results 1 to 25 of 29