  1. Replies
    1
    Views
    331

    Lon Scanner FX

    Is anyone familiar with this program from Echelon. If I understand correctly I will need a copy of Echelon's manual ISO/IEC 14908-1 t o be able to read the diagnostic codes.
  2. Replies
    5
    Views
    1,241

    Hi, Yeah this was canned app I got with the then...

    Hi, Yeah this was canned app I got with the then new Spyders at a HW class. No comm issues, tried cycling and resetting. As a company have moved on and not doing HW. I can't blame Mgmt, to many...
  3. Replies
    5
    Views
    1,241

    Honeywell Spyders ERRRRR

    Hi, So I go to this job put in almost a year ago, Spyder with vav app and the guy is confussed, says a couple boxes started behaving funny. The setpoint jumps 5deg when he puts it in. Not using WM...
  4. Thread: 33cst carrier

    by short243
    Replies
    1
    Views
    396

    Hi, Which VVt version. It has been quite a while...

    Hi, Which VVt version. It has been quite a while but if I remember right in VVT III,at the stat not software, the timed over stuff was in category 2 with the schedule info and only had the limit. In...
  5. Replies
    6
    Views
    1,229

    Hi, If you have bacnet networks in different...

    Hi, If you have bacnet networks in different buildings they might be on different IP subnets. You need one bcu on a subnet that has the address of the rest of the bcu's on that subnet, acts kinda...
  6. Replies
    6
    Views
    1,229

    to connect to the minimonitor you need Tranes...

    to connect to the minimonitor you need Tranes serial adapter. I assume you are bacnet over ip so be careful you don't mess up your bbmd tables when you replace bcu ip address.
  7. Replies
    3
    Views
    779

    Hi, What version of windows. If you go to control...

    Hi, What version of windows. If you go to control panel do you see an icon for lon, Lonworks plug and play. Check your settings. don't have a computer with me but near top on left, there are choices,...
  8. Hi, There is no back door. You must call Trane...

    Hi, There is no back door. You must call Trane support. When you try logging in it will say invalid and give you a challenge question, this question changes everytime you try to log in so you have to...
  9. Replies
    8
    Views
    1,513

    Hi, Sorry for the delay, log in issues. Spyder...

    Hi, Sorry for the delay, log in issues.

    Spyder Tool Niagara-AX Version Compatibility
    Spyder Tool Version Niagara-AX 3.0 Niagara-AX 3.1
    Niagara-AX 3.2 Niagara-AX 3.3 Niagara-AX 3.4
    1.5.0 Not...
  10. Replies
    8
    Views
    2,954

    Had same problem recently, running Windows 7. Had...

    Had same problem recently, running Windows 7. Had to logon using incorrect user name and password, after it kicked me out I could use correct and it let me in. Seems strange the correct one wouldn't...
  11. Replies
    8
    Views
    1,513

    There is also an issue of which tool was used, an...

    There is also an issue of which tool was used, an older Jace may not communicate correctly with a new Spyder. The new Spyders use a different tool set.
  12. Replies
    13
    Views
    1,374

    Thanks I will try that, I had always been told to...

    Thanks I will try that, I had always been told to link mark nvo of controller (spyder in this case) and point in recieving controller, never tried selecting whole controller and picking point.
  13. Replies
    13
    Views
    1,374

    Hi, I tried two ways, from the input of the...

    Hi, I tried two ways, from the input of the Spyder and I created an nvo in the Spyder and tried linking from that to nvi of Smart (1st post in thread), both way I got a block with 1-16 in,s. I must...
  14. Replies
    13
    Views
    1,374

    Uh, from the instruction I thought that is what I...

    Uh, from the instruction I thought that is what I was doing. Binding from the input of the Syder to the input (in this case the nvitempin) of the Smart Act. using link mark and link from was supposed...
  15. Replies
    13
    Views
    1,374

    By blink I mean the binding input value to the...

    By blink I mean the binding input value to the nvi duct temp in connected @10 stays solid but output value of the input block will show the input value for a few seconds then show nan for a few...
  16. Replies
    13
    Views
    1,374

    I have been doing some reading and came across...

    I have been doing some reading and came across tuning proerties, Nothing on how to configure them but sounded like it could be something to look at so I checked station and both Spyder and Smart are...
  17. Replies
    13
    Views
    1,374

    Honeywell Smart Actuator

    Hi, I am trying to send a supply air temp to a smart actuator from a Spyder using AX. I have tried binding to the AI of the Spyder and tried creating a NVO then binding to that. It appears the...
  18. Replies
    6
    Views
    1,165

    Custom

    Hi, I am doing some custom stuff. I used Image Ready and got the fan working, will try the % stuff in a few days, other project got put on the front burner. I just need some higher end stuff for a...
  19. Replies
    6
    Views
    1,165

    Thanks a bunch

    Don't know why I thought you had to create the GIF in AX. Much thanks
  20. Replies
    6
    Views
    1,165

    Next question

    Never thought of that, uh but in ax how do you do that, and can you bind an image to a point, IE: a VAV box to show position at 25,50 75and 100%.
    I am new at this end of stuff (graphics). I can make...
  21. Replies
    6
    Views
    1,165

    niagara graphics animation

    Ok I'm an idiot. Kinda new to this end of stuff so please bear with me. I want to animate a supply fan. I thought I was following directions, it will change state from 1 image to another but that's...
  22. Replies
    28
    Views
    4,530

    looked on honeywell site

    After I posted went to honeywells site, it reads like Spyders will talk on Lon but only peer to peer with other sylk enabled Spyders. Other devices may later be sylk enabled but I doubt it since the...
  23. Replies
    28
    Views
    4,530

    Honeywell Spyders

    Hi, We have only used Spyders on jobs with Jaces. I was wondering if spyders will talk to each other and other lon devices without a Jace on the link. I have never tried it and just thought about it...
  24. Replies
    0
    Views
    582

    Vykon controllers

    Hi, I heard a while back that Vykon was coming out with some new controllers. Maybe something like Honeywell Spyders and or AHU, VAV etc..
    Anyone heard anything.
  25. Replies
    6
    Views
    785

    Thank's Smokies

    Hi, Some one had an override in a basement box, called Building MGR and he had done it becuase they work late there.
    Thanks again, I didn't think about an ovr causing that, but it makes sense...
  26. Replies
    6
    Views
    785

    UH ....Question

    Hi, I was under the impression a VAV couldn't be in a common space in VAS, and in Area. I will check to insure all boxes are either in area or are common spaces. None show up as available but...
  27. Replies
    6
    Views
    785

    Tracer Summit V17

    Hi, I have a site with only one Intellapak and recently it won't go unocc at night. Ran trends and VAS doesn't go Unocc but area does so RTU stays Occ., no Morning Warmup. Not sure when it quit,...
  28. Replies
    17
    Views
    2,166

    Are there duct heaters in the boxes. If so put a...

    Are there duct heaters in the boxes. If so put a sensor in the duct before the box so it will know the incoming temp and it will work stand alone. You can then run the unit off of a sensor in the...
  29. Thread: Lon Spec

    by short243
    Replies
    4
    Views
    765

    yep, 1st thing I tried.

    yep, 1st thing I tried.
  30. Thread: Lon Spec

    by short243
    Replies
    4
    Views
    765

    I can direct connect anywhere on the bus, usually...

    I can direct connect anywhere on the bus, usually in the boiler room (where I was Tuesday and Rapid Link is there too) and see the entire link. Hooked up the phone and tested and couldn't see the 1...
  31. Thread: Lon Spec

    by short243
    Replies
    4
    Views
    765

    Lon Spec

    We have a small job that's been in about 2yrs. They finally decided to put in a phone line. There is one CVHU XL10 that won't talk when you call in but on site using direct connect it does. I'm...
  32. Replies
    2
    Views
    461

    XL15C Database

    Hi, I have a building that every 3-5 months will scramble parts of the database. I have seen a database scramble when comm blinks in and out rapidly but everytime it is looked at comm seems good, not...
  33. Replies
    1
    Views
    615

    Johnson A19AAF-12

    Hi, Ok I know what an A19 is, used them for years in refrig.. It appears to be a mechcanical stat. Came across one not in the books (on line) or distributor has in his book. It is the "F"...
  34. Replies
    4
    Views
    640

    Hi, Since no one has jumped in I'll take a stab...

    Hi, Since no one has jumped in I'll take a stab at it. Not sure what you are asking. Where do you want to take the humidity and co2 reading from, the space? A varitrac is a damper in the duct work...
  35. Thread: Spyder Help

    by short243
    Replies
    16
    Views
    2,786

    Hi, I'm not a ggod one to respond. I do some with...

    Hi, I'm not a ggod one to respond. I do some with Spyders but not a lot. I will be watching with interrest though. I looked and don't have that .jar file either but havn't tried locating the latest...
  36. Replies
    12
    Views
    1,926

    Hi, Well I guess nothing has changed, to bad as...

    Hi, Well I guess nothing has changed, to bad as Honeywell has some good products, guess they figure support is an expense rather than an asset like so many other manufactors:confused:
  37. Replies
    12
    Views
    1,926

    Honeywell tech support any good

    Hi, A couple years ago we changed from Honeywell to Vykon. I was only doing controls part time then, the reason given was tech support was a lot better. To make a long story short the people doing...
  38. Replies
    8
    Views
    639

    Hi, Not sure I understand the question. The...

    Hi, Not sure I understand the question. The Niagara network will talk to other brands using Niagara framework , IE, a JCI branded Jace can talk to a Vykon branded jace or a etc. branded jace because...
  39. Thread: Reset Setups

    by short243
    Replies
    16
    Views
    1,305

    Hi, It is the new "way to reduce energy"....

    Hi, It is the new "way to reduce energy". Reseting by demand. It works best if most keep thier tsat's in the same SPT area, but some are always going to turn them way down or up, hence wieghting the...
  40. Thread: Reset Setups

    by short243
    Replies
    16
    Views
    1,305

    Hi, I have been getting spec's lately that call...

    Hi, I have been getting spec's lately that call for resets based on avg space temp. Last one was very tight, for cooling
    70 avg space temp > 74 supply temp
    74 avg space temp > 55 supply temp...
  41. Replies
    1
    Views
    499

    Spyders ...are they fixed yet

    Hi, I love the concept but we had so many problems that we ended up using them as IO modules, hey they are cheap. I keep hearing they were "on the verge of getting the bugs out". Is anyone using them...
  42. Replies
    8
    Views
    1,458

    Hi, Very good advice, find out what you have....

    Hi, Very good advice, find out what you have. Relay packs to turn on RTU's maybe ..... 12 systems, are there bridges? Zones?
  43. Replies
    10
    Views
    1,462

    Ok, I'm confused, the BO is enabled, fan is off...

    Ok, I'm confused, the BO is enabled, fan is off .... fan should start and go to min Hz, after proving fan on, PCM will then ramp up drive. What is your end of range set at, I ask the question to able...
  44. Replies
    2
    Views
    561

    Hi, Not sure if it is what you are asking but...

    Hi, Not sure if it is what you are asking but Carrier used to have a N.A.M. (network access module) that used a 9 pin connector.
  45. Replies
    13
    Views
    1,380

    He is correct in that the I-VUE is just an...

    He is correct in that the I-VUE is just an interface. The 6400 is your best bet for custom programing.
  46. Thread: Tridium

    by short243
    Replies
    247
    Views
    14,220

    Hi, I don't know about targeted training but...

    Hi, I don't know about targeted training but suspect it just a matter of time. The logic portion of it seems to be straight forward, it's the terminology that first bothered me. Coming from a...
  47. Replies
    23
    Views
    1,558

    Hi, also same problem

    Hi, Been doing mech for several years but into controls only a couple.
    We have the same issue with JCI on some DX controlers. We only have a couple site with JCI, mostly Trane and Vykon, but it is...
Results 1 to 47 of 47