  1. Replies
    38
    Views
    2,024

    They've come a long ways, but still not...

    They've come a long ways, but still not perfect... software wise. It's a little bit of a love/hate relationship. If you're new to the product it's not so bad.
  2. Replies
    38
    Views
    2,024

    Gee, I wonder how come no one mentioned the...

    Gee, I wonder how come no one mentioned the Spyder yet... :rolleyes:
  3. Thread: BBMD vs VPN

    by digo
    Replies
    15
    Views
    436

    Here are a few other links: BBMD article...

    Here are a few other links:
    BBMD article by Bill Swan (Alerton BACnet guru who has since passed away)
    Contemporary controls pdf titled What is BBMD and Why Should I Care?
  4. Replies
    14
    Views
    433

    It appears the the web feature is unlicensed,...

    It appears the the web feature is unlicensed, which means you won't be able serve up graphics to a web browser.
    Beyond that, the JACE is having a problem initializing the RAM disk, which is where...
  5. Replies
    14
    Views
    433

    Try this: Go to Platform Administration and...

    Try this:
    Go to Platform Administration and click "Change Date/Time"
    Click "Use Local", then Save.

    Go to the File Transfer client and browse to niagara/lib on the JACE (right side), and browse...
  6. Replies
    6
    Views
    243

    User dana (Tridium's hardware engineer) explains...

    User dana (Tridium's hardware engineer) explains what you're seeing on this thread:
    https://www.niagara-central.com/ord?portal:/discussion/DiscussionThread/13385
  7. Replies
    7
    Views
    544

    I'm assuming this is coming from the fact no one...

    I'm assuming this is coming from the fact no one responded to your question here:

    EBI is a branch only product. There may be only a few Honeywell contractors who stuck around with SymmetrE...
  8. Replies
    32
    Views
    1,824

    Damn, is that a one minute timeout? Sent from...

    Damn, is that a one minute timeout?

    Sent from my MB886 using Tapatalk 2
  9. Replies
    32
    Views
    1,824

    Once your post count is up and you apply for Pro...

    Once your post count is up and you apply for Pro membership I think that becomes an option...
  10. Replies
    32
    Views
    1,824

    bacnet id defaults to 1338... leetspeek?

    bacnet id defaults to 1338... leetspeek?
  11. from that last link:

    from that last link:
  12. Replies
    8
    Views
    399

    When using declutch, return to minimum mechanical...

    When using declutch, return to minimum mechanical stop. Part of their new adaptation function, read up on 63-2633
    Also there's a service switch that should be set for at least 2 seconds prior, or...
  13. Replies
    7
    Views
    346

    http://www.invertekdrives.com/contact/enquiries.as...

    http://www.invertekdrives.com/contact/enquiries.aspx?distributorID=51
  14. Replies
    5
    Views
    271

    My cross reference search shows the L7033A1207/U...

    My cross reference search shows the L7033A1207/U is the direct replacement, but didn't see it as available....
  15. Replies
    12
    Views
    584

    Our rule was to not start work on SymmetrE on...

    Our rule was to not start work on SymmetrE on Fridays. You could easily start on a Wednesday and still have a 30% chance of still being there on a Friday... no joke.
  16. Replies
    12
    Views
    584

    I too cut my teeth on CARE 5/7 and SymmetrE...

    I too cut my teeth on CARE 5/7 and SymmetrE R300.2 and R310. Database synchronizations with CARE, on large campus networks - think dozens of ilon600s with multiple point servers - was just a...
  17. Thread: Station Starting

    by digo
    Replies
    3
    Views
    171

    SpyderTool 5.201 or later eliminates this...

    SpyderTool 5.201 or later eliminates this nonsense. Basically the tool is initializing the control logic on station startup (think opening up the controlLogic wire sheet) on each spyder.
  18. Replies
    1
    Views
    134

    Sounds like you just need to reinstall all of the...

    Sounds like you just need to reinstall all of the existing modules for the filter to apply. You can do that from the software manager view. Highlight all of the "Up to Date" modules and click...
  19. java.net.ConnectException: Connection refused:...

    java.net.ConnectException: Connection refused: connect

    The connection refused tells me it's likely an issue with the fox port not being open, or the incorrect port # being used.
    If it were a...
  20. https://www.niagara-central.com/ord?portal:/discus...

    https://www.niagara-central.com/ord?portal:/discussion/DiscussionThread/14474
  21. Replies
    9
    Views
    623

    Can you not access the link I posted abbove on...

    Can you not access the link I posted abbove on niagara-central?
    read up on docs\EngNotes\LinuxSupervisor\docEn_LinuxSupervisor.pdf

    To start the platform daemon:
    <user>@<host>:/usr/bin#...
  22. Replies
    5
    Views
    487

    really? 1 year warranty is standard in our...

    really? 1 year warranty is standard in our channel, I'd expect that to be the case across the board, considering hardware-wise it's the same product across all channels.
  23. Replies
    9
    Views
    623

    The installer shell script is meant for RHLE 5,...

    The installer shell script is meant for RHLE 5, which distro are you attempting to install it on?
    https://www.niagara-central.com/ord?portal:/dev/file/Linux_AX_Supervisor_Notes
  24. Replies
    5
    Views
    487

    https://www.niagara-central.com/ord?portal:/discus...

    https://www.niagara-central.com/ord?portal:/discussion/DiscussionThread/15303

    Not counting the ECC patch issue from a few years back (field recoverable), I have run into this only once in the last...
  25. Thread: NDIO Active Input

    by digo
    Replies
    7
    Views
    307

    Correct, it's simply saying to keep the power for...

    Correct, it's simply saying to keep the power for the ndio isolated, when using the IO-34 module. So in the case of your CO2 sensor, don't use the same power supply that powers the ndio.