  1. Thread: A/C renew

    by tranedog
    Replies
    13
    Views
    461

    AC RENEW WORKS for what it is intended to do! It...

    AC RENEW WORKS for what it is intended to do! It De-Oil fouls interior of the copper or aluminum tubing allowing for better oil return to compressor and better heat transfer between the...
  2. I really would have liked to see the wrap...

    I really would have liked to see the wrap installed per manufacture specifications to get the correct "R" value... It is suppose to have a 3/4 inch air gap between the duct and under side of the wrap...
  3. Replies
    18
    Views
    1,585

    Where are you located? We could make you...

    Where are you located? We could make you something... Empire Metal Products, Phoenix, AZ www.empiremetalproducts.com


    Sent from my iPad using Tapatalk HD
  4. Replies
    5
    Views
    848

    Copeland X reference Sent from my DROID RAZR...

    Copeland X reference

    Sent from my DROID RAZR using Tapatalk 2
  5. Replies
    5
    Views
    848

    They also have a FREE APP with that info...

    They also have a FREE APP with that info...
  6. Replies
    14
    Views
    4,203

    Are you allow to do that there??? It isn't a code...

    Are you allow to do that there??? It isn't a code violation??? Looks Great...
  7. Replies
    63
    Views
    5,264

    Yeah... God loves us SERVICE TECHNICIANS Sent...

    Yeah... God loves us SERVICE TECHNICIANS

    Sent from my DROID RAZR using Tapatalk 2
  8. Replies
    63
    Views
    5,264

    Sorry but you are incorrect! Sent from my...

    Sorry but you are incorrect!

    Sent from my DROID RAZR using Tapatalk 2
  9. Replies
    63
    Views
    5,264

    It is soooo possible to have this happen so if...

    It is soooo possible to have this happen so if anyone tells it cant they are full of crap! It not an install related problem... it is an act of God, period. You of had a Surge Protector on your...
  10. Replies
    319
    Views
    24,945

    I haven't had any problems with using it in...

    I haven't had any problems with using it in direct sun... never has gone black

    Sent from my DROID RAZR using Tapatalk 2
  11. Replies
    31
    Views
    8,199

    I worked at Service Experts it was way beyond...

    I worked at Service Experts it was way beyond corporate... the Manager was a two face b****!
  12. Replies
    319
    Views
    24,945

    Call Travis @ Tech Support they will take care of...

    Call Travis @ Tech Support they will take care of you... they are awesome! :troll2:
  13. Replies
    17
    Views
    1,582

    The main reason why the capacity starts to tank...

    The main reason why the capacity starts to tank at temperature above 95* is due to the scroll compressor not the r410a... scroll compressor just dont hold there capacity above 95* as well as...
  14. Replies
    17
    Views
    1,582

    I have been around since we use R12 in...

    I have been around since we use R12 in Residential Air Conditioning and then we went to R22 and now we are using R410a... I like working with R410a better than the rest and as long as you design your...
  15. Thread: Cooked by Cap

    by tranedog
    Replies
    1
    Views
    1,259

    Cooked by Cap

    https://plus.google.com/photos/116517504827586863327/albums/5756251585759213137?authkey=CJXc0eO6io-m5gE
  16. Replies
    6
    Views
    1,910

    Here is the link to the information regarding the...

    Here is the link to the information regarding the #9 Item i.e. Drip Guard

    https://docs.google.com/open?id=0B7bGB2quXfyoZWQ3YWIxZmItMmM1Mi00YTU5LTgwZDYtODliMzNhMTAzMGNh
  17. Replies
    6
    Views
    1,910

    9) UPFLOW AIR HANDLER BAFFLE - This baffle is...

    9) UPFLOW AIR HANDLER BAFFLE - This baffle is only included
    with Air Handler models. See note below.
    NOTE: Be careful not to discard the baffle. It is located under
    the collection cells in the...
  18. Thread: sight glass??

    by tranedog
    Replies
    42
    Views
    4,246

    The Refrigerant manufactures say... do not use a...

    The Refrigerant manufactures say... do not use a sight glass on any R-4XX blend system because they will show bubbles due to the chemistry of the blended refrigerants...
  19. Replies
    27
    Views
    2,112

    Please reference the following website- 29.92...

    Please reference the following website-
    29.92 inch Hg Vac. = 0 microns boiling point of water will be 80 F
    29.90 = 500 microns -10 F
    28.92 = 25401.07 microns
    1” Hg Vac. = 25401.07 microns

    ...
  20. Replies
    27
    Views
    2,112

    Oh BARBAR.... please read all my posts... I...

    Oh BARBAR.... please read all my posts... I stated all the exceptions and minus 10 degrees (F) at 500 microns is the boiling point of h2o (ie WATER)... And TRANEDOG has been MISTAKEN but NEVER...
  21. Replies
    27
    Views
    2,112

    you guys are hilarious.... too big of a vacuum...

    you guys are hilarious.... too big of a vacuum pump will freeze water during an evacuation... I don't know what to say about this whole thread besides... O My Gosh....
  22. Replies
    27
    Views
    2,112

    Really... really???? OMGosh...

    Really... really???? OMGosh...
  23. Replies
    11
    Views
    2,135

    AWESOME!!!

    AWESOME!!!
  24. Replies
    27
    Views
    2,112

    a vacuum lowers your boiling point temperature...

    a vacuum lowers your boiling point temperature from sea-level pressure ie. 212 degrees (F) to -10 degrees (F) at 500 microns so if you are boiling you are not freezing... da-dut-da :-)
  25. Replies
    16
    Views
    1,264

    btu test and amps

    btu test and amps
  26. Replies
    27
    Views
    2,112

    No... not if you are triple evac in cold climate...

    No... not if you are triple evac in cold climate or walk-in freeze. if you are not in a cold (freezing / wet atmosphere) then no need to triple evac just evac down to 500 micron min.
  27. Thread: running hot

    by tranedog
    Replies
    71
    Views
    3,928

    Mike - I am not seeing you have a problem with...

    Mike - I am not seeing you have a problem with your charge... 190 degree hot gas (discharge line) is not high...
  28. Replies
    12
    Views
    722

    is the 7 1/2 ton system a dual circuit evap? if...

    is the 7 1/2 ton system a dual circuit evap? if only a single circuit would be approx. 1.15to 1.2 piston which you can take a 0.9 or 1.09 and drill out with orfice drill bits to the correct size. If...
  29. Replies
    46
    Views
    3,525

    cfm=fpm x duct area square foot --- use a...

    cfm=fpm x duct area square foot --- use a anemometer at main return to find your entering air then check your supply the same way
  30. Replies
    17
    Views
    1,487

    0% / 6% / 15% silver solder sticks... can be...

    0% / 6% / 15% silver solder sticks... can be soldered using either turbo torche or an Oxy-Acetylene Torche... get proficiant at both
  31. Replies
    26
    Views
    1,509

    Please submit the pressures and temperature in...

    Please submit the pressures and temperature in the mode you are hearing the noise ...... :putergreet:
  32. Replies
    29
    Views
    2,751

    Thank you for the heads up. Do you have any...

    Thank you for the heads up. Do you have any pictures or dimensions of the new case?
  33. Replies
    106
    Views
    11,026

    You dont have to print a paper copy... you can...

    You dont have to print a paper copy... you can print a virtual copy as a PDF format to your desktop then export it to your Kindle or any other device.
  34. Replies
    30
    Views
    2,411

    I really like my SMAN3 it is awesome

    I really like my SMAN3 it is awesome
  35. Replies
    16
    Views
    3,643

    I have had atleast one every since they came out...

    I have had atleast one every since they came out way over 10 years ago and has been the best way for me to assure I have the right tool for the task at hand without making three trips to get a...
  36. Replies
    15
    Views
    1,244

    Hydraulic Swager Set and Rachet Copper Bender

    Hydraulic Swager Set and Rachet Copper Bender
  37. Thread: best flex

    by tranedog
    Replies
    6
    Views
    619

    ATCO is good flex as long as it is installed and...

    ATCO is good flex as long as it is installed and used correctly
  38. Replies
    20
    Views
    967

    SWEET... It still looks like the charge is low...

    SWEET... It still looks like the charge is low but since I/We are not there I dont know... you determined the charge by getting id wb and od db... correct?
  39. Replies
    17
    Views
    2,268

    THE ONLY PERSON ON HERE MAKING ANY SENSE is...

    THE ONLY PERSON ON HERE MAKING ANY SENSE is stevewh... everyone else is way over thinking it!
  40. Replies
    20
    Views
    967

    you said the compressor was replaced... could the...

    you said the compressor was replaced... could the id coil be oil logged from the old compressor? and the system slightly under charged...
  41. Replies
    42
    Views
    2,697

    did you check the polarity to the furnace? if it...

    did you check the polarity to the furnace? if it reversed it will not operate....
  42. Thread: Compressor ?

    by tranedog
    Replies
    7
    Views
    530

    it slowed down a lot but as long as I have been...

    it slowed down a lot but as long as I have been doing this trade is you plan for the slow down... lol... Have fun and Be Safe
  43. Replies
    4
    Views
    1,357

    Call a Professional before you get hurt, PLEASE!

    Call a Professional before you get hurt, PLEASE!
  44. Thread: Compressor ?

    by tranedog
    Replies
    7
    Views
    530

    carrier carlyle.... 1970's thru 1980's

    carrier carlyle.... 1970's thru 1980's
  45. Replies
    20
    Views
    7,360

    It looks like it was designed by one the old...

    It looks like it was designed by one the old retired Bell Helicopter Engineers that lives over there in the H.E.B. area..... lol too funny
  46. Replies
    49
    Views
    5,069

    Low Charge .....Yes I Agree with the following...

    Low Charge .....Yes I Agree with the following questions..... In what position did you install the new txv .... is the powerhead at 9, 12 or 3 o'clock? also where is the sensing bulb located and in...
  47. Replies
    15
    Views
    1,071

    no I have mastered using ductulators it is just...

    no I have mastered using ductulators it is just much easier not having to run to another device when I can just do the math in my head...
  48. Replies
    15
    Views
    1,071

    flex duct does come in 9" it is the last odd...

    flex duct does come in 9" it is the last odd diameter it does come in but I like even numbers too... lol
  49. Thread: Thermostats

    by tranedog
    Replies
    9
    Views
    774

    but if you want to get into it... you could...

    but if you want to get into it... you could install an outdoor tstat at the equipment so at a predetermined temp you send a call for aux heat to kick in only when it is at or below the equipment...
  50. Thread: Thermostats

    by tranedog
    Replies
    9
    Views
    774

    no one mentioned aux heat only that it was a...

    no one mentioned aux heat only that it was a heatpump system....