  1. Weigh the charge in and forget it.

    Weigh the charge in and forget it.
  2. Charge by weight and forget it.

    Charge by weight and forget it.
  3. How do I come to that conclusion next time? I...

    How do I come to that conclusion next time? I knew it was close but not this bad.
  4. 16560 sensible

    16560 sensible
  5. Replacing it with a 2 ton

    Replacing it with a 2 ton
  6. 18125 cooling 25209 heating

    18125 cooling
    25209 heating
  7. The high was 90 today and the house never cooled...

    The high was 90 today and the house never cooled below 77. 900 sf 9' ceilings. 1.5 ton
  8. 25'

    25'
  9. I'm going back tomorrow to check. I'll post back

    I'm going back tomorrow to check. I'll post back
  10. Never got below 77 today. High was 90

    Never got below 77 today. High was 90
  11. Odd start up readings on a dual fuel??

    Started up a dual fuel Payne heat pump and a horizontal n coil. High pressures and superheat.
    Sp. 145
    Sh 17
    Lp 320
    Sc 10
    I'd wb 71
    Ret. 78
    Sup 58
    Od 80
  12. Replies
    4
    Views
    225

    Anybody have a wiring diagram for this furnace

    Anybody have a wiring diagram for this furnace
  13. Replies
    4
    Views
    225

    Coleman furnace sequencer

    I have a Coleman furnace m# 7670c856. With a sequencer that looks like it's normally closed. Spst. It's stuck open. What could I use to replace it? Relay? Why did they choose sequencer in the first...
  14. Replies
    8
    Views
    437

    Solder was bad on the back of the board

    Solder was bad on the back of the board
  15. Replies
    8
    Views
    437

    The no code thing is getting me

    The no code thing is getting me
  16. Replies
    8
    Views
    437

    It's a 2 stage 80% variable speed furnace. And an...

    It's a 2 stage 80% variable speed furnace. And an identical furnace sits next to it with no problems.
  17. Replies
    8
    Views
    437

    Intermittent nordyne issue

    Frigidaire fg7ta 080
    Start up sequence runs through until flame rectification and then quits. Flame sensor reads 2.8 ua. No led trouble codes. Voltage drops from 27 to 25 after gas valve. Jumper...
  18. They sell a kit for that at Mingledorffs

    They sell a kit for that at Mingledorffs
  19. Replies
    1
    Views
    269

    Trane twe120b stolen

    Got a dual circuit heat pump r-22 ref. stolen. Could I replace that with 2 5 ton heat pumps to keep from replacing indoor section.
  20. Replies
    19
    Views
    693

    The air handler is 8 years old and this is the...

    The air handler is 8 years old and this is the first motor replacement. Ho wants the ecm put back in. I will measure tesp when I return and post back
  21. Replies
    19
    Views
    693

    Thanks! A

    Thanks! A
  22. Replies
    19
    Views
    693

    What's the best way to convert to psc? It's a...

    What's the best way to convert to psc? It's a goodman aepf42601ba
  23. Replies
    19
    Views
    693

    ECM 2.3 opinions needed

    I have an ECM 2.3 and the motor windings check out fine but the plug that connects to the module is damaged from the module burning up. One pin is melted and black. Has anyone experienced this? ...
  24. Replies
    49
    Views
    2,804

    Fieldpiece sc-54 works for me

    Fieldpiece sc-54 works for me
  25. Replies
    3
    Views
    379

    :angel: that's what I was wondering. Now that I...

    :angel: that's what I was wondering. Now that I know there is no relay the answer is clear. Thanks!