  1. Replies
    5
    Views
    277

    I vote to stick with the original , Turbo. I also...

    I vote to stick with the original , Turbo. I also like that new roller tote they hay have for the B tank rig. A coworker had one on the job recently and I was giving him a hard time about it until we...
  2. Thread: Name that Tune

    by tech45
    Replies
    89
    Views
    1,867

    Men At Work... I hated anything top 40 back then...

    Men At Work... I hated anything top 40 back then but that song was an exception for me. Brilliant note selection and arranging.
  3. Replies
    29
    Views
    1,314

    On a new clean system the oil will stay clear (...

    On a new clean system the oil will stay clear ( or it should as long as the manufacturer and install tech were clean with their work ). The only difference is that on the TEZ 8 you can identify this...
  4. Replies
    29
    Views
    1,314

    The value comes in when you get on a system that...

    The value comes in when you get on a system that is wet or dirty. The fact that you can change the oil quickly or even identify the condition of the oil at a glance are features that are not offered...
  5. Thread: VRF

    by tech45
    Replies
    86
    Views
    5,342

    There is a new service pack for Tracer Summit...

    There is a new service pack for Tracer Summit released last week and ARCNET is no longer supported.
  6. Replies
    3
    Views
    158

    Aaon can be tough to deal with at times unless...

    Aaon can be tough to deal with at times unless you are in tight with a good distributor. However , there are no " on the shelf " units from them and the blower drive is selected based on customer...
  7. Replies
    90
    Views
    2,715

    This is correct , and just to explain further , ...

    This is correct , and just to explain further ,

    when the fans are turned on and off, the liquid line pressure after the condenser coil ( or receiver ) fluctuates, which may cause the...
  8. Thread: VRF

    by tech45
    Replies
    86
    Views
    5,342

    If that refnet question was serious , ... the...

    If that refnet question was serious , ... the answer is no. 40 inches from the outlet of the first to the inlet of the second. A little Mitsubishi humor in my last post , not sure where this thread...
  9. Thread: VRF

    by tech45
    Replies
    86
    Views
    5,342

    Replacing them with a BC Controller may be the...

    Replacing them with a BC Controller may be the best option.
  10. Thread: Hose gaskets

    by tech45
    Replies
    6
    Views
    424

    I thought the same thing as I was trying every...

    I thought the same thing as I was trying every which way to get the dang thing into the socket. I grabbed the biggest allen wrench I could get in and was determined just to ruin the hose and toss it...
  11. Replies
    34
    Views
    1,556

    So it seems that any statement made against it's...

    So it seems that any statement made against it's use as well.

    I've been installing a lot of foreign brands lately that don't allow filter driers and contain fairly expensive parts , so other...
  12. Replies
    34
    Views
    1,556

    ... and then there is the flux , flowing by means...

    ... and then there is the flux , flowing by means of capillary action the same as the filler. I'm guessing that we all heat the joint as to promote a full socket filler material weather brazing or...
  13. Thread: AAON wattmaster

    by tech45
    Replies
    3
    Views
    233

    Are you connecting with a service manager /...

    Are you connecting with a service manager / service tool or Prism ? Have you tried leaving the user interface unplugged for say a day and connecting again ?
  14. Thread: AAON wattmaster

    by tech45
    Replies
    3
    Views
    233

    This sounds like a firmware or EPROM issue....

    This sounds like a firmware or EPROM issue. http://www.orioncontrols.com/a/contacts/
  15. Thread: VRF

    by tech45
    Replies
    86
    Views
    5,342

    I think Daikin bought Goodman so you might want...

    I think Daikin bought Goodman so you might want to check that you have a minimum of 40 inches between refnets.
  16. Thread: Hose gaskets

    by tech45
    Replies
    6
    Views
    424

    I use the biggest allen wrench that will fit in...

    I use the biggest allen wrench that will fit in the hose end ( 5 /16 I think ) and it seats the new ones every time. But yeah I was frustrated by the time I tried that for sure , they are impossible...
  17. Replies
    12
    Views
    815

    That is usually what I find as no one notices the...

    That is usually what I find as no one notices the 14 gauge control wiring throughout the unit ( factory ). And a hero comes along with his 2 conductor brown residential wire and breaks the entire...
  18. Replies
    12
    Views
    815

    Check for ANY field installed interlock or device...

    Check for ANY field installed interlock or device such as duct smoke , fire alarm , co2 , etc. Aaon control circuit power supplies are sized just enough for the unit ( undersized in my opinion ) and...
  19. Replies
    17
    Views
    874

    I would say parallel boxes are more reliable due...

    I would say parallel boxes are more reliable due to the fact that series boxes are prone to being turned backwards from the main air. A parallel box can also operate " stand alone " ( heating ) if...
  20. Did the Aaons or the Munters have " modulating...

    Did the Aaons or the Munters have " modulating hot gas reheat " ?

    Modern standards make it tough for dx systems and outside air ( reheat options during dehumidification are few ) or aggressive...
  21. Thread: VRF

    by tech45
    Replies
    86
    Views
    5,342

    http://usa.mylinkdrive.com/categories/12/product_t...

    http://usa.mylinkdrive.com/categories/12/product_types/46/models/253/products/show/1755.html
  22. Replies
    7
    Views
    404

    Condensate drain pan is full ?

    Condensate drain pan is full ?
  23. Replies
    11
    Views
    438

    If your economizer controller has a demand...

    If your economizer controller has a demand control ventilation feature you could use that along with a 0 -10 vdc pressure transmitter. This feature is scalable in the new Jade I believe. Either way...
  24. Thread: Accutools

    by tech45
    Replies
    29
    Views
    1,229

    It must have been the week for it I recently got...

    It must have been the week for it I recently got mine back from him too. Mine was a first generation and he fixed the problem ( wear and tear abuse ) and updated it for the lower ambient operating...
  25. I guess if you have to say one way or other , yes...

    I guess if you have to say one way or other , yes a 90 degree square throat / heel 90 would be about right. It almost seems like that is too much because the entering air is not restricted by a duct...
Results 1 to 25 of 500