  1. Run your flues out the side of the furnace so...

    Run your flues out the side of the furnace so there is coil access. Media filter?!?!? Outdoor unit will have a blanket of crap on the coil in no time.. Not sure why they have stuck with that...
  2. Hybrid Geothermal. Waterfurnace Envision, Bryant Evolution

    Took out a lowboy oil furnace with a goodman 3ton ac, and a ducane 80% LP furnace and 5 ton goodman heat pump.
    Put in 2 Waterfurnace Split system heat pumps with waterfurnace coils., 2 Bryant...
  3. Replies
    30
    Views
    2,126

    We get very very few clogged drains with the...

    We get very very few clogged drains with the filter boxes we use. Good filter keeps the coil clean, which keeps the condensate clean.
  4. Replies
    30
    Views
    2,126

    Carrier and tempstar, 2- 2.5 ton. Certain serial...

    Carrier and tempstar, 2- 2.5 ton. Certain serial number range, they are junk. I have 5 that are needing changed. Lots of other expansion valve problems on coils say 5 years and newer… Changed quite...
  5. Replies
    30
    Views
    2,126

    Yeah there is a gap, had a couple traps on the...

    Yeah there is a gap, had a couple traps on the new furnaces clogged with what looks like grease. No other problems so far… Several bulletins on these furnaces… I enjoyed the emails about TXV's I...
  6. Oh yeah, I welded up the stand, also got one for...

    Oh yeah, I welded up the stand, also got one for the basement system to lay on that I made…………...
  7. Going to have a hybrid geo system for you to pick apart!

    https://farm4.staticflickr.com/3922/14640349145_7b35f35d6e_k.jpg

    I don't do geo's often, got a lot of time and will have more time into this job. Putting in 2 of the 5 series Waterfurnace split...
  8. Replies
    30
    Views
    2,126

    If we have to insulate, we usually do duct liner,...

    If we have to insulate, we usually do duct liner, always insulate attic stuff and garage stuff… Wrapping everything looks like poopy!
  9. Replies
    29
    Views
    3,987

    I wouldn't work out of anything I couldn't stand...

    I wouldn't work out of anything I couldn't stand up in the back of!
  10. Replies
    1
    Views
    295

    Looks good! Big job. Working on putting in 2...

    Looks good! Big job. Working on putting in 2 hybrid 5series units now.
  11. Replies
    30
    Views
    2,126

    I wasn't mad or nasty… I wish there was more...

    I wasn't mad or nasty… I wish there was more code enforcement here… Be less hacks…
  12. Replies
    7
    Views
    979

    No i rarely work on mobile homes… leave those...

    No i rarely work on mobile homes… leave those calls for some other company
  13. Replies
    30
    Views
    2,126

    Thanks!

    Thanks!
  14. Replies
    30
    Views
    2,126

    That or cell core.. can use either one.

    That or cell core.. can use either one.
  15. Replies
    30
    Views
    2,126

    2" yes, one for exhaust, one for intake...

    2" yes, one for exhaust, one for intake...
  16. Replies
    6
    Views
    1,045

    I don't know why this isn't done more.

    https://farm3.staticflickr.com/2917/14374827779_3816301693_o.jpg


    Plenum, and all the returns in the attic, spray foamed, all the way around.

    First time I have seen this other than the one...
  17. Replies
    7
    Views
    979

    It wasn't what I was expecting.

    Of course it was in a trailer… coil so dirty the water was being sucked off it…

    https://farm4.staticflickr.com/3845/14374829159_4301bbaecd_o.jpg
  18. Replies
    30
    Views
    2,126

    Yeah we got a custom duct shop too… only so much...

    Yeah we got a custom duct shop too… only so much I can do, budget is only so much… Only a 2 ton system, plenty of airflow, 8x24 drop…
  19. Replies
    30
    Views
    2,126

    Some of my stuff from last week.

    Mr slim and a system change. Busy ass week with other stuff as well.

    Changeout sure wasn't my neatest….

    https://farm3.staticflickr.com/2923/14351991947_bbf1e3b283_o.jpg...
  20. Replies
    14
    Views
    1,548

    Presumably yes, the trap in 1 1/2" line could dry...

    Presumably yes, the trap in 1 1/2" line could dry out and let off some stink…
  21. Replies
    22
    Views
    1,375

    Im not shy about using my cable cutters, or the...

    Im not shy about using my cable cutters, or the pruning cutters in the truck….
  22. Replies
    22
    Views
    1,375

    I like what i see… What is the theory behind...

    I like what i see…

    What is the theory behind the riser between furnace and coil?

    Nice to see someone use metal. See too much flex and ductboard anymore.

    Where is the zone board?...
  23. Replies
    14
    Views
    1,548

    Yeah vent/drain….

    Yeah vent/drain….
  24. Replies
    14
    Views
    1,548

    Carriers has switched brands of heat packs...

    Carriers has switched brands of heat packs recently. Completely different and a piece of ****. BUT it gets a 10 year warranty.. Need a cube relay for one? Supply house gives you the whole heat...
  25. Replies
    14
    Views
    1,548

    Yeah, that is weird. Part number starts with...

    Yeah, that is weird. Part number starts with KFCEH i think