    Carrier Field Assistant 6.0

    I was told it was possible to use Firefox instead of I.E. as interface. Just installed FA 6.0 but can't find where to change default browser, still uses I.E..

    Anyone know?
  2. Replies
    33
    Views
    1,631

    I like the Niagara platform, constant version...

    I like the Niagara platform, constant version suck, but what else can do what it does? License a driver and integrate a device. Granted some are easier than others and docs sometimes suck, but who...
  3. Chipkin has some good manuals

    Chipkin has some good manuals
  4. Replies
    6
    Views
    279

    Done a few 15C to AX and the first definitely...

    Done a few 15C to AX and the first definitely sucks, but ain't that always the case?
    There is a "15C for learn" object that you would copy to lon network, match up device, do a learn, upload, and...
  5. Station Dislpay name in supervisor keeps changing

    How do you keep the display name of a niagara station in a supervisor from changing. Have reset it over and over but always goes back. Cannot figure out where it derives the display name.
  6. Replies
    9
    Views
    591

    If I recall correctly LonSpec backups are .ntb...

    If I recall correctly LonSpec backups are .ntb files unsure what .mdb files are.
  7. Replies
    5
    Views
    413

    you know whats weird---I get that same stupid...

    you know whats weird---I get that same stupid face thing for the letter P on one of my stations when it text messages. Don't know why. Just thought I'd throw it out there.
  8. Replies
    4
    Views
    321

    Each unit now has its own OA sensor. What they...

    Each unit now has its own OA sensor. What they want is a uniform OA temp which will be the same for all units. If I pick 1 unit to broadcast its OA temp then done deal, but where I could do that on a...
  9. Replies
    4
    Views
    321

    Carrier RTU-Open Outside Air Question

    Have a customer with a few sites that each have appx. 20 Carriers with RTU-Open controllers. The units, as is, use their individual OA sensor for various control strategy's. What customer would like...
  10. Replies
    5
    Views
    377

    7.67 is latest version as far as I know

    7.67 is latest version as far as I know
  11. Replies
    0
    Views
    224

    Reliatel to AX integration issue

    Doing a Trane Reliatel integration and am having an issue where I need to be able to allow the tenant to have set point adjustment from the wall sensor but only between ranges. Sensor installed are...
  12. Replies
    2
    Views
    266

    Sent you a palette that contains a 15C for Learn...

    Sent you a palette that contains a 15C for Learn device that makes it easier to work these devices. More info. on Buildings Forum on these devices also.
  13. Replies
    1
    Views
    154

    Adding modules to FX-60

    Have to add a Lon network to an FX-60, there are no lon modules install as it came, it is licensed for lonworks. I am leary of connecting to Johnson device with my Webs workbench and transferring the...
  14. Thread: vav help

    by mechmike2
    Replies
    6
    Views
    475

    KMC has some offerings for standalone VAVs. Going...

    KMC has some offerings for standalone VAVs. Going to try out their "Simple VAV" on a box tomorrow to see how they work.

    Envirotec another option for standalone.
  15. Replies
    4
    Views
    293

    After you set up your Rapidzone system the last...

    After you set up your Rapidzone system the last tab is "Finish" in which you can save the job. After saving job a network tab opens up, if you open the network tab it brings up another screen and if...
  16. Replies
    10
    Views
    514

    I have 5.1 Tools on an older laptop, trying to...

    I have 5.1 Tools on an older laptop, trying to get the new 6.0 version because I can't get 5.1 to work on new Windows 7 computer, unsure why.
  17. Replies
    10
    Views
    514

    Sent a copy of mod stat report off to a Carrier...

    Sent a copy of mod stat report off to a Carrier controls tech I know and he noted error that stated "could not allocate mem spaces", means that board needs replacing.
  18. Replies
    10
    Views
    514

    Carrier RTU Open Question

    Have an RTU that has quit twice on a "Program Stopped Alarm". Literature rather lacking on what causes the alarm. Downloading controller rings it back for a while. Anyone seen this before?
  19. Replies
    3
    Views
    295

    That is pretty much the same way I have it set up...

    That is pretty much the same way I have it set up now, just trying to get the 1 and done included in the sequence.
  20. Replies
    3
    Views
    295

    Spyder Morning Warm Up

    I am trying to figure a way to do morning warm up in a spyder. I am stuck at keeping warm up off after Return Air reaches set point or should I say keeping warm up from re-initializing if RA should...
  21. Replies
    3
    Views
    262

    Sent you some docs. Check out 74-2958 around page...

    Sent you some docs. Check out 74-2958 around page 60 is point lists
  22. Replies
    17
    Views
    1,218

    A series fan box is a constant volume application...

    A series fan box is a constant volume application where , if balanced properly, delivers the same amount of air to the space constantly. They work OK if balanced properly. I think people complain...
  23. Replies
    6
    Views
    333

    Thanks for the info.. If a lon integration is not...

    Thanks for the info.. If a lon integration is not possible can't a TCI be installed and I could use a Comm 4 driver on Jace? From what I have been researching it seems to be a good alternative, other...
  24. Replies
    6
    Views
    333

    That would be greatly appreciated. Serial # is...

    That would be greatly appreciated. Serial # is J97H72633. Having a difficult time getting info about these units.
  25. Replies
    6
    Views
    333

    Old Intellipak integration question

    Wonder if anyone knows if all Trane Intellipak RTUs are compatible with LCI-I cards. Unit is from 1997 and design sequence is "M". Was told I may need to check #'s on boards to determine if cards...
  26. Replies
    19
    Views
    2,869

    I have a customer with a number of 1997...

    I have a customer with a number of 1997 Intellipaks and is looking to install LCI cards in them to integrate into a lon network. Does anyone know if the LCI is compatible with a the older I-Paks,...
  27. Replies
    11
    Views
    941

    I have worked with it.

    I have worked with it.
  28. Replies
    11
    Views
    941

    You may want to see if the York units are...

    You may want to see if the York units are configured correctly, that requires using their Simplicity software tool which you can get from your local York/JCI dealer, if I remember correctly there is...
  29. Replies
    11
    Views
    941

    Are your York units Intelli-Comfort with...

    Are your York units Intelli-Comfort with FieldServer bacnet gateways?
  30. Replies
    7
    Views
    424

    Did one recently with xl10s and 15cs about 250...

    Did one recently with xl10s and 15cs about 250 devices, put in 3 jaces and supervisor. Time consuming, very. All 15cs were programmed differently so couldn't make one RTU template. Vavs and Fpts...
  31. Replies
    3
    Views
    202

    Thanks for the info. Now i'm getting licensing...

    Thanks for the info. Now i'm getting licensing errors, jace won't boot. Will go by distributors shop Monday with jace in hand, license is in and valid but still dead in water. Should have waited till...
  32. Replies
    3
    Views
    202

    connecting to a new fx60

    Have a job that speced an Fx60 jace. I am a Webs user and have never hooked up to a new Fx jace. Thought all FX jaces have an embedded workbench in them and could be accessed through browser but am...
  33. Replies
    9
    Views
    693

    I opened up one of the Venom apps and I see what...

    I opened up one of the Venom apps and I see what you mean, you don't have the option to bring the AV in as an enum point. Definitely curious as to how they were able to. Only way I know to bring in...
  34. Replies
    9
    Views
    693

    It looks like you are trying to add a network...

    It looks like you are trying to add a network point from spyder tool into niagara point folder. You would have to add the point to the spyder control program and then proxy it into niagara
  35. Replies
    9
    Views
    693

    Try using a custom enumeration instead of a val...

    Try using a custom enumeration instead of a val ubyte point.
  36. Replies
    9
    Views
    693

    In the advanced tab of the software point in the...

    In the advanced tab of the software point in the Spyder select MSV instead of AV
  37. Replies
    20
    Views
    1,044

    Just get a Lon Spyder and make your life simpler

    Just get a Lon Spyder and make your life simpler
  38. Replies
    4
    Views
    229

    Sorry, if your points were going stale your unit...

    Sorry, if your points were going stale your unit should default to its preset setpoints in the unit which should prevent your freeze up issue.
  39. Replies
    4
    Views
    229

    It sounds like you have stale points, meaning the...

    It sounds like you have stale points, meaning the data is not updating on your front end. What type of front end do you use to access your equipment?
  40. If you are writing to the nviDACLSP (LON) it will...

    If you are writing to the nviDACLSP (LON) it will override other setpoint. Unsure about bacnet but would assume the same.
  41. Replies
    25
    Views
    2,273

    Are the Java settings the same in each PC? I have...

    Are the Java settings the same in each PC? I have found unchecking keep temp files on computer fixes browser issues.
  42. Replies
    2
    Views
    330

    Actually after playing around with the setpoints...

    Actually after playing around with the setpoints I found that changing the nciOccHeatSetpoint changes both the Occ Heat and the Morning Warmup setpoint in the RTU, updates on the HI to reflect...
  43. Replies
    2
    Views
    330

    Trane IntelliPak MWU question

    Been a while since I've dealt with these units. I was under the impression that the morning warmup used the occupied heating setpoint as its termination setpoint but the warmup seems to shut down...
  44. Thread: Vehicles

    by mechmike2
    Replies
    0
    Views
    270

    Vehicles

    Boss is looking to get new trucks and is looking into Nissan mini cargo vans. i have heard that you can't fit a 6' ladder in 1 of these. Anyone have one? What do you think?
  45. Thread: Trucks

    by mechmike2
    Replies
    23
    Views
    1,509

    Trucks

    Boss is looking to get new trucks and is looking into Nissan mini cargo vans. i have heard that you can't fit a 6' ladder in 1 of these. Anyone have one? What do you think?
  46. Replies
    11
    Views
    938

    It is recommended that you change the default...

    It is recommended that you change the default user name and password when you commission a Jace. It makes it a pain in the a.ss but it is recommended. There are programs out there that can search for...
  47. Drop 15cforLearn device on lon bus, rename as...

    Drop 15cforLearn device on lon bus, rename as needed. Match up field device to the XL15cfor Learn device. In actions do a learn then upload. You can then view wiresheet of I/O, Flex and Logic...
  48. Check your email

    Check your email
  49. Thread: Carrier vvt

    by mechmike2
    Replies
    4
    Views
    535

    Check out one of these zoning stats Honeywell...

    Check out one of these zoning stats Honeywell TB6980B1006/U. Have used them in the past. Would install discharge sensor and the stat would simply open damper if space needed cooling and supply air is...
  50. Replies
    16
    Views
    1,173

    If you are licensed the honeywell AX Wizard...

    If you are licensed the honeywell AX Wizard module makes it simple. If you not licensed the lonHoneywell module is there but not as easy.