    Charge Migration or Wax?

    AIRFLOW unit R-22 8 tons, did a compressor change about 2 years ago. New Liq line solenoid valve and filter installed and a new moisture/liquid line sight glass installed. Ran great all this time. ...
  2. Replies
    7
    Views
    582

    LLT was 98 @110 OAT, Haven't cracked open the air...

    LLT was 98 @110 OAT, Haven't cracked open the air handler so if there is a LL filter it may be in there. Looking at the Trane TXV kits it looks like everything is bolt on extept the LL. I stopped...
  3. Replies
    7
    Views
    582

    Unit is 12 seer, the amp draw as originaly stated...

    Unit is 12 seer, the amp draw as originaly stated is 23 amps for a plate listed 25 FLA. Since the thermal cut off is 220 Deg the compressor temp. reached that without question. I'll have to try to...
  4. Replies
    7
    Views
    582

    Have I missed anything?

    Builder installed, 6 year old Trane Model 2TTR2060E1000A, R-22, Split Unit, Gas Pack., 3/8 X 7/8 line set approx. 26' to 30'. No line dryers or filters. OSA ambient was 110 DB. High side: 325 PSIG....