    Testing

    Hi,

    I've decided to go with the current system for this year and switch to just the electric hot water next year to see the difference. My current numbers are as follows though:

    Average cost...
  2. Replies
    15
    Views
    2,885

    Ground temperature 50F. Water I'm trying to heat...

    Ground temperature 50F. Water I'm trying to heat 50F. Is the COP still 4?
  3. Replies
    15
    Views
    2,885

    There seems to be a bit of differing on this. To...

    There seems to be a bit of differing on this. To add an extra element to the argument I do have a 50 gallon buffer tank and the 50 gallon DHW storage so when the system does come on it is heating 100...
  4. Replies
    15
    Views
    2,885

    Model

    Hi,

    The model is a DXW-55HW. A 4 tonne unit that creates heat and domestic hotwater.

    If I did not run the heatpump in the summer what would the ramifications be in terms of letting it sit idle...
  5. Replies
    15
    Views
    2,885

    Efficiency

    Thanks for the reply. The COP for this unit is 3.92. But that seems to be under a very specific set of circumstances which makes this difficult to figure out exactly just using that number. What I'm...
  6. Replies
    15
    Views
    2,885

    Answers

    We don't have any info on heating DHW only with electric. We just finished the house in December and commissioned the geothermal in February.

    The heat from the geothermal unit goes into the...
  7. Replies
    15
    Views
    2,885

    Clarify

    Just to clarify, we are not using the geothermal for cooling. We don't need to cool in this area.

    Also the loop in the SuperStore is more accurately a separate zone.
  8. Replies
    15
    Views
    2,885

    Desuperheater for DHW

    Hi,

    I've been running my DX geothermal system since February and am quite happy with it. Now that the weather has warmed up we don't need it for heat (most of the time). We have an extra loop...
  9. Replies
    8
    Views
    1,024

    Great. Thanks. I did actually write...

    Great. Thanks. I did actually write non-programable. As of yet overshoot hasn't been a problem. I guess it might now that we're getting into the shoulder months. We only commissioned the system in...
  10. Replies
    8
    Views
    1,024

    Hmm. That's almost what it was set to before. The...

    Hmm. That's almost what it was set to before. The contractor said that the HP was jumpered only to use the second stage. At that point the aquastat was set to 110 with a 10 differential. I will...
  11. Replies
    8
    Views
    1,024

    It goes to second stage at 85F. First stage is...

    It goes to second stage at 85F. First stage is 110 with a 20 differential.
  12. Replies
    8
    Views
    1,024

    Thanks for the reply. My contractor has setup...

    Thanks for the reply.

    My contractor has setup a 2 stage aquastat on the buffer tank. Originally they had jumpered the heat pump and had a single stage aquastat so that it only came on at stage 2....
  13. Replies
    8
    Views
    1,024

    Controlling the system

    Hi,

    I just had a geothermal system installed. It was a retrofit but on a home that is brand new. All in-floor poured slabs on 3 floors ICF construction. It's a DX system. I have a 50 gl buffer...
  14. I really do appreciate all of the input from...

    I really do appreciate all of the input from everyone. I spend a lot of time answering questions about computers, digital cameras, printers etc... and it is nice to see that lots of other people are...
  15. Can you clarify that? I am having issues with...

    Can you clarify that? I am having issues with flow. The water heaters depend on a flow sensor to turn on. When only one zone is open only one heater comes on. The plumber who installed the system was...
  16. I thought you might have misread my message and I...

    I thought you might have misread my message and I assumed you thought I had some separate electric radiant heaters. I am aware that in-floor radiant heat is a radiant heat source.

    I do think that...
  17. I'm not sure what you mean by radiant units?...

    I'm not sure what you mean by radiant units? These are tankless hot water heaters. They heat 3 concrete slabs with hot water. The geothermal will be attached to this system. They aren't separate....
  18. Thanks for the replies. I think they are run in...

    Thanks for the replies. I think they are run in parallel. Like this?

    http://kevincunningham.net/pipe.gif

    The heating contractor who is installing the geothermal uses Tekmar and I do think I'll...
  19. We don't have gas here (yet). Most homes are...

    We don't have gas here (yet). Most homes are heated with oil. Our electric rates are 12 cents per kilowatt hour. Your comment on control is part of my issue with this system. As you may know these...
  20. Point of use tankless boilers for in floor radiant

    I have just finished building a house. It was basically a turnkey home. The home is about 4200 square feet. We are located in Nova Scotia, Canada, northeast just above Maine. The builder used 2 of...