  1. Replies
    7
    Views
    801

    you need composite out the BAbsTime into a...

    you need composite out the BAbsTime into a program object.
    This is code I used to get a global TOD for a graphic..

    BAbsTime now = NviwhateverTime();
    // BAbsTime now = Clock.time();

    String...
  2. Replies
    9
    Views
    696

    I had a BASRTP that I use for onsite programming...

    I had a BASRTP that I use for onsite programming that got jacked up for no apparent reason. I downloaded a new firmware package from ccontrols and that fixed it..
    Looks like a comm issue with the...
  3. Sorry just try http://csicubed then open...

    Sorry just try http://csicubed then open products..
  4. TenantEye by Csi3 is popular and easy to set up.....

    TenantEye by Csi3 is popular and easy to set up.. Free 2 hr trial.. http://csicubed.com/portofolios/tenant-eye/
  5. Thread: CCN AX

    by EMPadvocate
    Replies
    17
    Views
    2,114

    Thanks for the response. The serial device I'm...

    Thanks for the response. The serial device I'm looking at also does TCP/IP (B&B-elec VESR901) also so I'm going to have to play with it.
    Evidently the CCN workstation has to be setup for a...
  6. Thread: CCN AX

    by EMPadvocate
    Replies
    17
    Views
    2,114

    I have a customer with CCN and multiple bldgs...

    I have a customer with CCN and multiple bldgs connected to the 0 network. They have issues with the underground between buildings and my thought was using serial RS485/ethernet converters with the...
  7. Replies
    9
    Views
    2,060

    Maxline (who picked up Infocon driver line) has...

    Maxline (who picked up Infocon driver line) has an N2 driver for Tridium (ibmsN2.jar) that works very good.. I would add the external RS485 comm port card though to the JACE and add separate networks...
  8. Replies
    24
    Views
    3,156

    Current US IRS defines mileage expense as...

    Current US IRS defines mileage expense as .55/mile; sorry for you guys getting paid .50/mile; your company is making .05/mile on you and maybe the IRS needs to know about that.. I always thought...
  9. Replies
    11
    Views
    2,060

    If you're using Tridium you can change the out of...

    If you're using Tridium you can change the out of service attribute using the virtual gateway; this will stay in the BCI config unless its blown out back to default..
  10. Replies
    5
    Views
    641

    Thanks, I dont have a variable SCHEDNUM or MODE...

    Thanks, I dont have a variable SCHEDNUM or MODE in the printout.. There are no jumpers on the terminal block.. I am starting to believe RMTOCC is addressed wrong in the printout. I need to look at it...
  11. Replies
    5
    Views
    641

    Thanks, RMTOCC (0x400F) is at 1 and is not...

    Thanks, RMTOCC (0x400F) is at 1 and is not responding to a write command; I have set OCCPC01S (0x9000) to 0 and also cleared all registers to 0x9008 which I believed cleared all three events...
  12. Replies
    5
    Views
    641

    CCN to Modbus

    I have a 33CNTRAN485 in modbus mode on a 50EJ RTU. The printout from the Comfortview SW had "C48/50E Standard Tier Rooftop" in the status display pages and "C48/50E Standard Tier Rooftop -0,2" in...
  13. After integrating a few server farms I feel that...

    After integrating a few server farms I feel that some IT managers pushed into facilities/sustainability aren't qualified or experienced enough to actually make the initial correct decisions as to an...
  14. Replies
    0
    Views
    380

    Reliatel Analog DAT control

    Anyone have experience doing VAV supply air cooling setpoint on the RTRM board using an analog DCV? The literature also says that this can be accomplished on the RTAM board.. What will yield the best...
  15. Replies
    13
    Views
    1,711

    You need the software from Trane to talk to it...

    You need the software from Trane to talk to it with USB cable; SW is actually pretty well done.. The MAC addresses mean nothing to BACnet MS/TP you actually have to enable it to use it (checkbox);...
  16. Thread: PLC

    by EMPadvocate
    Replies
    30
    Views
    4,714

    The base DL06 has 3 slots open for analog I/O...

    The base DL06 has 3 slots open for analog I/O since one is used for the ECOM100 ethernet device. You can add another modbusTCP device in the ECOM100 configuration or another DL06 or a gateway and...
  17. Replies
    9
    Views
    1,588

    You need to license BACnet IP and everything...

    You need to license BACnet IP and everything BACnet is out on eth1 which you designate as part of the configuration. I just did a HW job with the new BACnet spyders using 3 of the Contemporary...
  18. Thread: PLC

    by EMPadvocate
    Replies
    30
    Views
    4,714

    I use the Automation Direct DL06 for central...

    I use the Automation Direct DL06 for central plant work using Turbocors and VSDs. I use the com2 port for direct compressor control and the ECOM100 card for modbusTCP talking to a JACE.. For the VSD...
  19. Replies
    9
    Views
    1,588

    Doing MS-TP using onboard RS-485 on a large...

    Doing MS-TP using onboard RS-485 on a large network distributed over 4 com ports??? Well good luck with that.. Thats something I wouldn't consider with a JACE. JAVA is built on top of IP and is most...
  20. Replies
    14
    Views
    1,013

    Engenuity.com is also picking up a lot of BACnet...

    Engenuity.com is also picking up a lot of BACnet product.. They had a new display product I wanted to look at
  21. Replies
    9
    Views
    1,740

    Interstate Batteries has these.. Try #NIC0088...

    Interstate Batteries has these.. Try #NIC0088 which I took off the package..
    They were the JCI suppliers;
  22. Replies
    4
    Views
    763

    If you know Spyders you should'nt have much of a...

    If you know Spyders you should'nt have much of a problem.. just blow out all the nvi, nvo, nci lon network points before you pull in a app off the palette and then re-add - for boolean I used...
  23. Replies
    9
    Views
    2,121

    I am thinking the AX/FX JACE product can't tunnel...

    I am thinking the AX/FX JACE product can't tunnel over the serial port. Perhaps you can use a usb to ms/tp (BASRTP-B from ccontrols.com) from the OWS you have. Don' t have a copy of CCT yet so I...
  24. Replies
    58
    Views
    9,500

    OPC, sounds like your machine is upside down with...

    OPC, sounds like your machine is upside down with evap temp higher than cond side; compressor is in demand limit and won't take off. Hot gas bypass (HGB) will help with these situations.. Use the TC...
  25. I might be mistaken but I did'nt see anything in...

    I might be mistaken but I did'nt see anything in the this discussion about the issues with duo-core PCs and USB serial port devices. Personally I had issues with the off-shore devices (Frys) with my...
  26. If you find a clean way to read the compressors...

    If you find a clean way to read the compressors individually please share it.. I had to write the comp selector as a numeric write and the exec a program object on a numeric point using the same...
  27. Replies
    6
    Views
    778

    I solved the issue by taking Willf650's advice...

    I solved the issue by taking Willf650's advice and wrote a value of the average space temp to nviSpaceTemp and setting occupied space temp setpoints. Writing nviAplicMode would not trigger the heat....
  28. Replies
    11
    Views
    1,384

    Danfoss makes a EXV package that works well with...

    Danfoss makes a EXV package that works well with chillers; has pressure sensor and temp sensor; We have been using a lot of these with good results on DX turbocor applications - they have large...
  29. Replies
    6
    Views
    778

    Trane LciDac Issue

    I installed a Trane Lci Discharge Air Control for ReliaTel card on a 50T Voyager VAVw/VSD on supply fan unit with low temp heat option and I can't find the right way to put the unit in heat....
  30. Replies
    13
    Views
    1,402

    GBAS panels analog output circa 1998 were...

    GBAS panels analog output circa 1998 were probably .5 to 4.5 VDC; therefore 100% (provided correct parameter chosen - % FLA) is 4.5 VDC
  31. Replies
    9
    Views
    2,549

    Hyperterminal works.. I believe it is 7 E 1 @...

    Hyperterminal works.. I believe it is 7 E 1 @ 9600; "HI=170" to get you in.. I might be wrong here, its been over 10 years since I did it. This is just command mode. This old dos stuff can you copy...
  32. Replies
    30
    Views
    2,299

    If they don't map in automatically through the...

    If they don't map in automatically through the import file. you might need to talk to JCI about it.. My first FX-40 job I had to bring in PHX.prn files and that was broken as it would only bring in...
  33. Replies
    30
    Views
    2,299

    I'm thinking you're saying you want to add the...

    I'm thinking you're saying you want to add the controller XT object to your points folder.. I would'nt do that. The DX passes the poll message thru to the XT bus when you add them I think and the XT...
  34. Replies
    8
    Views
    3,180

    What needs to be done to integrate an Alerton...

    What needs to be done to integrate an Alerton apex Rev 2.A install with 4 trunks? Workstation, dongle, database etc... got thrown out. It has 4 trunks.. don't know how tuxs are addressed according to...
  35. Replies
    4
    Views
    1,150

    look at csimn.com "babel buster" they have a...

    look at csimn.com "babel buster" they have a Modbus TCP product that I hear is very good. I use the JACE2-L product myself with the Modbus TCP driver...
  36. Replies
    15
    Views
    4,499

    Remember that USB to serial won't work with...

    Remember that USB to serial won't work with HVACPRO; you have to have a real serial port; I hear on the new SW its fixed..
  37. Thread: Dx9100

    by EMPadvocate
    Replies
    3
    Views
    833

    if you use the on/off pid try a pb of 20 at .2...

    if you use the on/off pid try a pb of 20 at .2 then run into timer block for min on time if need be; start with 90 diff; better yet go to SDREO (san Diego regional energy office) and have them buy...
  38. Replies
    5
    Views
    891

    Are you saying you cannot connect online to the...

    Are you saying you cannot connect online to the NAE/NIE over the network to do a check? One way is to pull the N2 off and shoot the bus with HVACPRO, build a controller device.log on that bus and...