  1. Replies
    4
    Views
    850

    REPLY: Both will reduce the airflow volume but...

    REPLY: Both will reduce the airflow volume but with dampers you can really throttle down on the supply cfm as required. So long as the supply air coming to your basement can exit its way past door(s)...
  2. Replies
    26
    Views
    2,451

    'I beleive hvacfella said, "Im liking Goodman...

    'I beleive hvacfella said, "Im liking Goodman more and more since they redesigned their equipment. Their 93 and 95% gas furnaces are well engineered , not overly controlled , EASY TO WORK ON, and...
  3. Replies
    26
    Views
    2,451

    REPLY: Im liking Goodman more and more since...

    REPLY: Im liking Goodman more and more since they redesigned their equipment. Their 93 and 95% gas furnaces are well engineered , not overly controlled , easy to work on, and extremely quiet . The...
  4. Replies
    4
    Views
    850

    REPLY: Here is the approx. airflow effect you can...

    REPLY: Here is the approx. airflow effect you can expect : A 15x8" trunk duct handles 750 cfm total. Two 6" supply ducts for your basement would handle a total of 250 cfm . In other words, you will...
  5. On a replacement , are you having trouble...

    On a replacement , are you having trouble physically fitting them in due to how much taller they are ?

    Couldnt they move to a four-row coil and shorten the overall size ?

    Whats your take on...
  6. REPLY: Well, ill certainly consider the P66 ....

    REPLY: Well, ill certainly consider the P66 . Thanks.
  7. REPLY: Good question..id like to know that...

    REPLY: Good question..id like to know that myself. Plus, according to this :
    Address:http://www.updinc.com/326H%2B327H.htm

    ... the specs lists the Controls max. storage temperature at 85 f. ; ...
  8. REPLY: Much obliged. Looks like this model would...

    REPLY: Much obliged. Looks like this model would do the job : http://www.icmcontrols.com/products/head_pressure_icm326h.html

    When it says :120/208/240 v. "INPUT" , are they referring to the input...
  9. Im working with a few residential split systems...

    Im working with a few residential split systems on a small commercial building for some Dentists and Doctors ; they often want to run the mechanical cooling when the outside temp is 50 f. due to...
  10. REPLY: Your post was uncalled for and facietous....

    REPLY: Your post was uncalled for and facietous. The installation instructions didnt call for the Inducer Assembly to have hi temp sealant on it . I dont think Goodman is junk and ive never said it...
  11. REPLY: Yes. ITs fixed. I went back and switched...

    REPLY: Yes. ITs fixed. I went back and switched it over to rightside drain and also applied some hi temp. sealant to the back of the Draft Inducer Fan Assembly to make sure it is sealed tight when...
  12. REPLY: Okay...i shall do exactly this. Many...

    REPLY: Okay...i shall do exactly this. Many thanks.
  13. 'It is when when someone makes broad statements...

    'It is when when someone makes broad statements like; "All (pick a brand) are crap" or "All (pick a brand) coils leak" etc. that I feel they are being unprofessional jerks
    '

    REPLY: Agree . If...
  14. 'You're entitled to your opinion and I am...

    'You're entitled to your opinion and I am entitled to mine. I have no problems with pointing out faulty features of certain models of equipment, but to bash a brand is indeed petty and unprofessional...
  15. 'Brand bashers make the HVAC profession appear...

    'Brand bashers make the HVAC profession appear petty and unprofessional.
    '

    REPLY: Knocking a particular brand comes about from repeated experience with failures, poor serviceability, and/or...
  16. REPLY: No, the big rubber exhaust elbow is in...

    REPLY: No, the big rubber exhaust elbow is in the factory position ; yes, i pushed the plastic fitting into the big rubber exhaust elbow nipple -- that section drains fine. I am indeed wrong, as i...
  17. REPLY: On the Goodman GCS, it uses a rubber...

    REPLY: On the Goodman GCS, it uses a rubber drain fitting that is part of the vent elbow right after the discharge of the vent motor ; its located on the bottom of the elbow and it is draining fine....
  18. REPLY: Its a GCS . Im quite certain in 'my'...

    REPLY: Its a GCS . Im quite certain in 'my' instructions it showed a box leftside drain with rightside trap ; in any case, i pulled out the box rightside plug and it didnt drain either with furnace...
  19. New Goodman 90 plus , 115 k. in counterflow...

    New Goodman 90 plus , 115 k. in counterflow position. I installed it per the instructions , has a good pitch toward the front of the furnace, no blockages detected. The problem is this : the leftside...
  20. REPLY: While im not opposed to making one, id...

    REPLY: While im not opposed to making one, id rather have one that is intended for the use ; theres got to be something exactly what im looking for ...and by jove... im going to find it.
  21. Im looking for a suitable mirror for when i have...

    Im looking for a suitable mirror for when i have to work blind on a piece of equipment..or on an auto. Id like it be preferably : magnetic and on a flexible short wand for easy positioning...and...
  22. Replies
    33
    Views
    3,147

    Both have put out some of the worse junk over the...

    Both have put out some of the worse junk over the years ; especially in the 1980's. With both, youre paying ALOT of money for thier huge advertising budget . There are other brands out there that...
  23. Im taking a long RV trip to the Southwest to see...

    Im taking a long RV trip to the Southwest to see some friends in a few different cities and wouldnt mind attending a Service , Installation, Controls, or HVAC Sales type (one day) seminair...
  24. Reply: Good, then its settled...we're going with...

    Reply: Good, then its settled...we're going with Liquid Nitrogen. Could i ask you to be the Installation Foreman on the job and ill be the guy who makes sandwiches and coffee for the team .
  25. Reply: Ok...then scratch the Brine Chillers ;...

    Reply: Ok...then scratch the Brine Chillers ; How can we apply Liquid Nitrogen to freeze the area by the Levee ??? Thats the 2 dollar question.