  1. Replies
    21
    Views
    3,066

    I always do them upright and stuff them with...

    I always do them upright and stuff them with ANYTHING. Chicken livers with bacon wrapped over the top, fresh sausage, salmon spread ... the combinations are limitless and good
  2. Thread: FHP Problem

    by Alf
    Replies
    14
    Views
    1,541

    Looks like the discussion got a little off track....

    Looks like the discussion got a little off track. Does this unit have hot gas bypass, from one of the posts it sounded like it did. If so, what is it set at? It could simply be a bad valve or an...
  3. Replies
    3
    Views
    1,022

    Believe it, most all TXVs are bidirectional. You...

    Believe it, most all TXVs are bidirectional. You do lose some capacity when used in the reverse direction, but they work. All Geo manufacturers get by with one except in split system applications...
  4. Replies
    24
    Views
    2,556

    Use PE pipe with fused connections. It's the...

    Use PE pipe with fused connections. It's the same thing that is used in loop fields and has gained approval for inside use.
  5. Thread: Geothermal

    by Alf
    Replies
    8
    Views
    940

    Go to WaterFurnace.com. There is a dealer...

    Go to WaterFurnace.com. There is a dealer locater using your Zip Code on this site.
  6. Thread: Rotolocks

    by Alf
    Replies
    18
    Views
    1,536

    Rotolocks

    Dealing with large scrolls, 15 ton. I need to take a poll. Would you prefer sweat or rotolock terminations on the compressor? We presently use rotolocks, manufacturing would rather braze.
  7. Replies
    2
    Views
    680

    WaterFurnace EW360 and EW540 30 and 50 ton units....

    WaterFurnace EW360 and EW540 30 and 50 ton units. These should meet the requirements.
  8. Replies
    9
    Views
    1,062

    Agree, if your protection level is only 25, you...

    Agree, if your protection level is only 25, you are skating on the edge of freezing in the coax, especially if flows are low. Protect the loop to 15, and get flow rates up, and the system should be...
  9. Replies
    9
    Views
    1,062

    NOthing wrong with a 32 deg. loop this time of...

    NOthing wrong with a 32 deg. loop this time of year depending on location. the question is the flow through the units, is it high enough? Rough number look for 4-6 deg. drop (given that the...
  10. Replies
    12
    Views
    1,310

    When you suspect the air coil, it's good practice...

    When you suspect the air coil, it's good practice to disconnect the fan motor and freeze the coil. You can then see which end tubes are not freezing.
  11. Replies
    6
    Views
    623

    Not sure I understand your question. Do you want...

    Not sure I understand your question. Do you want to use a vertical loop bore hole as a water well? If so, I don't think you have to worry about a code violation between the refrigerant and the...
  12. Replies
    10
    Views
    1,055

    Had a call once, trying to sell me an...

    Had a call once, trying to sell me an electrically operated bed. I told her it would be of no use because I am Amish. She appologized. I don't think it occurred to her why come I had a phone.
  13. Thread: Life with BACnet

    by Alf
    Replies
    3
    Views
    682

    How about Fort Wayne? Check out WFI.

    How about Fort Wayne? Check out WFI.
  14. Thread: circ pump question

    by Alf
    Replies
    9
    Views
    908

    Does the term NPSH ring a bell? Negative...

    Does the term NPSH ring a bell? Negative pressure on a circulator pump is almost always a bad thing. Check the mfg's data for pump and see what the NPSH (net positive suction head)is required and...
  15. Thread: Geotherm questions

    by Alf
    Replies
    28
    Views
    2,866

    I can understand that, are you able to get the...

    I can understand that, are you able to get the interruptable rate on electricity?
  16. Thread: Geotherm questions

    by Alf
    Replies
    28
    Views
    2,866

    Personally, I would stay away from anything that...

    Personally, I would stay away from anything that depends on fossil fuel for back-up. You will have better EERs with a DX system than a hydronic system just do to the fact that you have one less heat...
  17. Thread: Geotherm questions

    by Alf
    Replies
    28
    Views
    2,866

    Any system is only as good as the installer. Ask...

    Any system is only as good as the installer. Ask around, get some references from customers. I do know that there are good dealers up there.
  18. Thread: Geotherm questions

    by Alf
    Replies
    28
    Views
    2,866

    I agree about the bury depth of the water line,...

    I agree about the bury depth of the water line, not too important as there will constant flow as it gets colder out. You can cool with a water to water unit, it is perfectly capable of generating 45...
  19. Thread: Geotherm questions

    by Alf
    Replies
    28
    Views
    2,866

    Pond loop is out of the question, pond too...

    Pond loop is out of the question, pond too shallow. A little hard to size a geo to supply all the heat at your design conditions, it would have to be really large.
  20. You cannot heat the earth with solar. The earth...

    You cannot heat the earth with solar. The earth is nothing but a large heat sink. The higher the delta T between the solar and the earth, the quicker it will disappear. You are ahead to put the...
  21. Thread: Hog Hair Filters

    by Alf
    Replies
    18
    Views
    1,820

    How do you feel about them. Would you rather...

    How do you feel about them. Would you rather have hog hair than a dog size of 1" throw away? How many are using factory filters or installing a better filter by another vendor?
  22. Thread: Reheat

    by Alf
    Replies
    14
    Views
    1,233

    We will be controlling water flow, the...

    We will be controlling water flow, the refrigerant control will not be an issue.
  23. Thread: Reheat

    by Alf
    Replies
    14
    Views
    1,233

    Yes, we will be controlling the flow through the...

    Yes, we will be controlling the flow through the coax to satisfy a discharge air temp sensor. Not really so difficult. Reheat is inherently not efficient, so the drop in EER can be justified.
  24. Thread: Reheat

    by Alf
    Replies
    14
    Views
    1,233

    Thank you all for the input. We are building...

    Thank you all for the input. We are building this machine per an engineer's spec, and there isn't one of course. This will be going on a water source machine and we will be generating our own hot...
  25. Thread: Reheat

    by Alf
    Replies
    14
    Views
    1,233

    I agree with you, but should I size for the...

    I agree with you, but should I size for the sensible capacity of the DX coil at an entering air condition of 80/67 or at a lower temperature? Thanks for the reply.
  26. Thread: Reheat

    by Alf
    Replies
    14
    Views
    1,233

    In the process of designing a hydronic reheat...

    In the process of designing a hydronic reheat system for DX cooling. What are your opinions on a set point for this system? Should the reheat equal the sensible capacity of the unit at 80/67 return...
  27. The last post said it all. There is nothing...

    The last post said it all. There is nothing wrong with the equipment or the concept, but poor installations can spoil it just like any other job. Hire a good loop contractor and make sure to put...
  28. Replies
    3
    Views
    942

    Check out WaterFurnace International. Could be...

    Check out WaterFurnace International. Could be ordered with Johnson FX10 controls which could give you LAN or Bac Net compatability.
  29. Thread: Square D breaker

    by Alf
    Replies
    7
    Views
    1,372

    What is the voltage of the panel. Q0 series...

    What is the voltage of the panel. Q0 series breakers are only 240 VAC
  30. If you want to learn more about refrigeration I...

    If you want to learn more about refrigeration I have had an opening for some time. We are ane equipment manufacturer and perform testing on our own units in a lab setting. I need someone that can...
  31. Replies
    9
    Views
    2,235

    Send me a resume at al_fordeck@waterfurnace.com. ...

    Send me a resume at al_fordeck@waterfurnace.com. Do you have any computer skills as well?
  32. Replies
    9
    Views
    2,235

    Jason. Hunting for an HVAC lab tech in NE...

    Jason. Hunting for an HVAC lab tech in NE Indiana. Do you have any practical experience?
  33. Replies
    28
    Views
    6,634

    To jeffkillen: Been there done that. Got to...

    To jeffkillen: Been there done that. Got to love those guys. I'll take them any day over a complainer that probably will not pay the bill!!
  34. Thread: Lab Tech

    by Alf
    Replies
    0
    Views
    1,255

    Interested in getting out of the service...

    Interested in getting out of the service industry? Have an opening for a lab technician for a manufacturing company. This will be a 2nd shift position. Need strong background in trouble shooting...
Results 1 to 34 of 127
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event