  1. When putting the male adapter for the drain make...

    When putting the male adapter for the drain make sure that the fitting is not too big to fit through the hole in the panel. The fitting we buy are too big so I just drill the hole a little bigger....
  2. I just remove it. Very easy.

    I just remove it. Very easy.
  3. Replies
    18
    Views
    1,177

    It was in a bulletin I got in the mail from my...

    It was in a bulletin I got in the mail from my distributor. It also had something about putting a float switch on one of the air handlers would cause problems with trips in the horizontal position....
  4. Replies
    18
    Views
    1,177

    Not supposed to use the charge assist with the...

    Not supposed to use the charge assist with the tam8. The bulletin that was sent to me said it will overcharge them. I checked with our rep about a job with an 1 1/8 lineset that had 22 feet vertical...
  5. Replies
    25
    Views
    3,600

    Are they using flex range connectors to tie into...

    Are they using flex range connectors to tie into the units?
  6. Replies
    24
    Views
    3,614

    Sure is.lol. I promise they're not all like that...

    Sure is.lol. I promise they're not all like that around here, but I sure do see my share.
  7. Replies
    8
    Views
    1,327

    Are they using the brooms and mops to adjust the...

    Are they using the brooms and mops to adjust the airflow? Very nice.
  8. Replies
    24
    Views
    3,614

    Yep. This is definitely one of the best I have...

    Yep. This is definitely one of the best I have come across. He acted surprised when I told him that his duct work wasn't right. I'm sure the x-13 motor that's in the unit won't last long.
  9. Replies
    24
    Views
    3,614

    Textbook install

    368141368151
    Found this one tripping on low pressure. I don't know how it was leaking water into the building.
  10. Replies
    8
    Views
    1,368

    Electrical? Drain? Both?

    I guess you get what you pay for. Not to mention it's a 4 ton system on 1100 square feet.
  11. Replies
    2
    Views
    323

    Sounds good. Thanks!

    Sounds good. Thanks!
  12. Replies
    2
    Views
    323

    Xl16i pressure transducer.

    I'm about to replace a pressure transducer on a xl16i heat pump. Is there a shader valve under it or do I need to recover the refrigerant. Thanks in advance!
  13. Thread: Wifi stats

    by La Air Man
    Replies
    12
    Views
    1,886

    I talked to one of the guys at our distributor...

    I talked to one of the guys at our distributor today and he said they still have the monthly fee. I will talk to my sales rep and see if he knows anything about the fee.
  14. Thread: Wifi stats

    by La Air Man
    Replies
    12
    Views
    1,886

    Wifi stats

    I have a customer that wants wifi stats installed with his xl16i Trane heat pumps so he can control the temperature from his phone. Trane does have a few options on wifi stats, but I wanted to get...
  15. Replies
    31
    Views
    4,125

    Have you had any problems with the blocks?

    Have you had any problems with the blocks?
  16. Replies
    31
    Views
    4,125

    There are joints in the wall. I have never had...

    There are joints in the wall. I have never had one leak yet. Even if I ran rolled copper I would still put an elbow where it goes outside because I personally don't like the big swoop with the rolled...
  17. Replies
    74
    Views
    8,586

    I just picked up a replacement coil for a...

    I just picked up a replacement coil for a b3bm-060k and it was a standard tube/fin design. This will be the second coil replacement in this unit since 96. Are their higher seer air handlers going to...
  18. Replies
    2
    Views
    499

    Thanks.

    Thanks.
  19. Replies
    2
    Views
    499

    Any Difference?

    Any difference between the mars h10-pm and the bacharach h10-pm leak detector? I can get the mars locally, but want to make sure there is no difference.
  20. Replies
    10
    Views
    968

    If I'm not mistaken, to get true locked rotor...

    If I'm not mistaken, to get true locked rotor amps you need to get an amp reading of the run and start winding at the same time with a good run cap. With an actual locked rotor.
  21. Replies
    18
    Views
    2,064

    IMO, that air handler and a 3.5 ton outdoor unit...

    IMO, that air handler and a 3.5 ton outdoor unit are a crappy system matchup under most real world conditions, especially with a unit that is intolerant of liquid stacking in the condenser, like the...
  22. Replies
    18
    Views
    2,064

    Gam5036 can move 1205 cfm at .5 static. The ari...

    Gam5036 can move 1205 cfm at .5 static. The ari rating is at 1335 cfm. At .3 it can move 1301 cfm. I don't think it can do it with tight ductwork.
  23. Replies
    34
    Views
    2,351

    Yep. Plenty of horses and coona$$es around...

    Yep. Plenty of horses and coona$$es around here.lol
  24. Replies
    34
    Views
    2,351

    Its a small world lol. The weather has been in...

    Its a small world lol. The weather has been in the middle 80's for the last month or so, but it stayed pretty cool today. Just waiting on the heat.
  25. Replies
    34
    Views
    2,351

    Does it have a micro channel coil?

    Does it have a micro channel coil?