    I would suggest you take a business class and...

    I would suggest you take a business class and understand overhead. All the skills you may think you have don't necessarily equate to a successful business and making money.
  2. Simple winding check for single phase units ...

    Simple winding check for single phase units

    Ohm the following
    R to C = ?
    S to C = ?
    R to S should equal the the total values of the RC and SC
  3. Replies
    38
    Views
    2,349

    If you are using rule of thumb for sizing today's...

    If you are using rule of thumb for sizing today's R410a equipment you are heading for disaster. A proper load calculation is required.
  4. Replies
    25
    Views
    2,216

    Please view this link. This is an industry wide...

    Please view this link. This is an industry wide problem affecting copper coils. Rheem has tin plated coils available to address this issue. Also, it is my understanding Rheem is going to an...
  5. Replies
    34
    Views
    2,443

    Depending on which Mitsubishi unit you are...

    Depending on which Mitsubishi unit you are working on the following gauge wire should be installed. If you are using a M-Series 14-3 if you are using the P-Series it is 16-3. You can use 14-3 with...
  6. Replies
    12
    Views
    699

    Spend the money and get a H10G leak detector. I...

    Spend the money and get a H10G leak detector. I has never failed me.
  7. Replies
    41
    Views
    4,118

    Change the TXV

    Change the TXV
  8. Replies
    14
    Views
    3,062

    Load

    What does the engineering data from Trane tell you?
  9. Replies
    14
    Views
    3,062

    TXV

    Yes Lennox used two different expansion valves there part numbers as I remember are 56J20 & 56J21 respectively. They are R22 TXV's. Not sure if they are the same number.
  10. Replies
    16
    Views
    2,063

    If you would like, I can run the load and see...

    If you would like, I can run the load and see what I come up with. I use Wrightsoft. Just send me all the information about the house.
  11. Replies
    14
    Views
    3,062

    Lennox Heat pump question

    I don't believe that is a match please see attached.
  12. Replies
    27
    Views
    2,819

    You should be getting a rebate for the Lennox...

    You should be getting a rebate for the Lennox System especially with that setup. Better check with your contractor.
  13. Replies
    19
    Views
    1,127

    So no one actually took the time to measure your...

    So no one actually took the time to measure your rooms, ceiling height, widows doors, whether you have carpet, wood floors, maybe some unusual room that has 50 computers, any overhangs over windows,...
  14. Replies
    10
    Views
    678

    Did any of these three companies offer a load...

    Did any of these three companies offer a load calculation to properly size your unit with all the remodel? Not to mention to make sure your ductwork is properly sized?
  15. Replies
    5
    Views
    1,454

    Lennox Warranty

    Yes
  16. Replies
    5
    Views
    1,454

    Lennox HP29 has a 10 year compressor and 5 year...

    Lennox HP29 has a 10 year compressor and 5 year parts warranty. I am not sure it is still possible to get an extended warranty though.