Search:

Type: Posts; User: beerado4u

Search: Search took 0.00 seconds.

  1. am i not seeing it? ...

    am i not seeing it?

    http://www.nordyne.com/Literature/7083500.pdf
  2. Replies
    7
    Views
    902

    yes use the charts it make it that much easier....

    yes use the charts it make it that much easier. And yes when it asks for Liquid temp it wants u to use a temp probe to read the line. Typical Subcooling.
  3. Frigidaire 2 stage 16 SEER Condenser inquiry/problem

    i know i could sit on the phone with nordyne tech support for 2 hrs, but i thought id give this forum shot. Welp, i have a 5ton frigidaire 2-stage 16 SEEER condenser w/ a comfort alert module. module...
  4. Replies
    19
    Views
    2,288

    Make sure all your duct work is connected below....

    Make sure all your duct work is connected below. (Crawl) ive came into numerous cases where it has been botched or animals used the flex to make a home. Since the homes are modular and ductwork is...
  5. Replies
    30
    Views
    2,919

    Goodman has value brand called gmc. Tan paint....

    Goodman has value brand called gmc. Tan paint. And amana i think is the 1up.
  6. Replies
    17
    Views
    1,459

    Goodmans manual says permanent damage to scroll...

    Goodmans manual says permanent damage to scroll tips if suction operates below 20psi for more than 5 seconds. :(:angel:
  7. Replies
    18
    Views
    1,787

    http://www.maxifrig.com/

    http://www.maxifrig.com/
  8. Replies
    18
    Views
    1,787

    :whistle: That makes sense now. I just found...

    :whistle:

    That makes sense now. I just found out that mo22 and most replacements should never be used in nitrogen charged units due to incompatibility with the oils. My work had me using it...
  9. Replies
    18
    Views
    1,787

    its called mx-22 by Maxi-frig. its said it right...

    its called mx-22 by Maxi-frig. its said it right on the jug. if i cant find the literature online i will post a pic up later when i have theh can in front of me. me and my dad were both amazed it...
  10. Replies
    18
    Views
    1,787

    one of the new r-22 replacements directions says...

    one of the new r-22 replacements directions says "works better without evacuation".
  11. Replies
    12
    Views
    2,525

    and i thought i was the only one with that...

    and i thought i was the only one with that brillaint idea. :cheers:
  12. Thread: dryer

    by beerado4u
    Replies
    9
    Views
    637

    Sounds like a restriction to me. U open both the...

    Sounds like a restriction to me. U open both the service valves :)
  13. Replies
    12
    Views
    2,525

    Ive trained myself to always crimp with my left...

    Ive trained myself to always crimp with my left hand, saves my forarms for cutting through s cleats.
  14. Replies
    6
    Views
    979

    My boss got me a yellow jacket expander. Great...

    My boss got me a yellow jacket expander. Great tool just splits the pipe sometimes, nothing a braze cant fix. Saves money on fittings and also= less brazes less chances for leaks.
  15. Replies
    30
    Views
    16,433

    Thats sad. I know a hardware store in detroit...

    Thats sad. I know a hardware store in detroit where u can walk in a and buy goodmans at wholesale with no mech license or anything.
  16. Replies
    14
    Views
    949

    I hope your not serious? Tom Brady is AWESOME. If...

    I hope your not serious? Tom Brady is AWESOME. If only the Lions could pick him up.
  17. Replies
    23
    Views
    5,214

    This is an awesome Thread.

    This is an awesome Thread.
Results 1 to 17 of 17
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event