  1. Replies
    2
    Views
    501

    Approx. 35.25 fthd across the pump. Taking into...

    Approx. 35.25 fthd across the pump. Taking into consideration, the pump's fairly flat curve, and if the pump is running at 1,750rpms you are probably pretty close or slightly over 210gpm. With fairly...
  2. Thread: HydroLock

    by retube
    Replies
    4
    Views
    289

    Both circuits equalized at the same rate.

    Both circuits equalized at the same rate.
  3. Thread: HydroLock

    by retube
    Replies
    4
    Views
    289

    I started up a fresh 35ton RTU today and the unit...

    I started up a fresh 35ton RTU today and the unit did not have enough condenser to clear the saturated vapor / suction gas that was in the suction line without limiting out on head pressure. I closed...
  4. Thread: HydroLock

    by retube
    Replies
    4
    Views
    289

    HydroLock

    Have you Hydro-Locked any MicroChannels yet? It's possible even on a perfectly charged unit! Receivers will be the new suction accumulators.
  5. There is a wooden guard-rail, it's on the lower...

    There is a wooden guard-rail, it's on the lower deck.:grin2: Would you believe that whoever installed it never plans on servicing it?!
  6. Replies
    2
    Views
    340

    I do have ABB Drives. The burnt mark is near the...

    I do have ABB Drives. The burnt mark is near the remote occupancy and enthalpy terminals. I also have lost the VFD Signal only in the past. Interesting.
  7. Replies
    2
    Views
    340

    Carrier RCB Boards

    Has anyone ever had a failure of a RCB Board on multiple different Z Series Units? The reoccurring failure point I have witnessed is near the J4 connector where the discrete inputs are landed. The...
  8. Replies
    10
    Views
    1,003

    Trane IntelliPak Microchannel Leakers

    Has anyone had any issues with the New Large IntelliPaks Condenser Coils? Just asking.
  9. Thread: PH Meter

    by retube
    Replies
    3
    Views
    561

    The Best

    Myron L
  10. Thread: lennox

    by retube
    Replies
    4
    Views
    496

    It is a pictorial schematic. If you learn how to...

    It is a pictorial schematic. If you learn how to read them there is nothing simpler.
  11. Replies
    42
    Views
    3,278

    Pronunciation

    A few years back, in the mid 90's, I had a service manager ask me if I had any applications where one of these new condensing Boilers called the Lennox Complete Heap would fit the bill!!!
  12. Thread: Comfortview 3.0

    by retube
    Replies
    12
    Views
    2,372

    Ask for 3.2

    Ask for 3.2
  13. Replies
    42
    Views
    3,278

    And Before The Pulse

    The HydroTherm Pulse Boiler. If it wasn't for the leaky heat-exchangers the Pulses were in a league of their own.
  14. Replies
    28
    Views
    6,624

    Not all compressors are the same.

    Ultimately the saving is derived from the use of the VFD's to more closely match the load. Isn't that the savings. The first biggest VFD compressor savings is on the centrifugal, second is found on...
  15. Replies
    13
    Views
    1,048

    The next best thing?

    The next best thing is when it is a really bad design!
  16. Replies
    45
    Views
    6,971

    Quantity

    It is not just isolated to Trane.:censored:
  17. Replies
    3
    Views
    855

    Lennox

    Would you happen to have the Lennox USB adapter #? I can't find it. Thanks in advance.
  18. Slugs of liquid and oil are on the horizon

    Do yourself a favor and install a small accumulator and your compressor will be forever great-full.
  19. Replies
    3
    Views
    855

    Lennox PC to L Connection

    Is the Lennox PC to L Converter just a standard RS-232 to RS-485 converter?
  20. Replies
    8
    Views
    701

    I see some compressor change-outs on the horizon....

    I see some compressor change-outs on the horizon. 200'?
  21. Replies
    7
    Views
    1,240

    More times than not you will find errors in the...

    More times than not you will find errors in the config tables of the controller that lock-up.
  22. Replies
    21
    Views
    2,333

    The scrolls weak link rest assured bearing...

    The scrolls weak link rest assured bearing trouble you have.
  23. Replies
    8
    Views
    3,309

    On a open or closed loop system the sensor is...

    On a open or closed loop system the sensor is usual located 2/3 way out on the system piping to get a actual system Delta P. Here it sound like they actual want to control to Pump Delta P. I wonder...
  24. Replies
    7
    Views
    1,240

    Do you also notice that it is always the same few...

    Do you also notice that it is always the same few controllers?
  25. Replies
    19
    Views
    2,634

    Just another over-thought Goobermint idea. If the...

    Just another over-thought Goobermint idea. If the truth were known, someone put on a multimillion dollar PowerPoint presentation and the consensus was, probably the gauges alone would pretty much fix...