Search:

Type: Posts; User: jtel

Page 1 of 2 1 2

Search: Search took 0.00 seconds.

  1. Replies
    25
    Views
    3,234

    Absolutely.

    Absolutely.
  2. Replies
    25
    Views
    3,234

    I did this work one summer and if the pay is door...

    I did this work one summer and if the pay is door to door this is a great job as long as you don't mind the hours. In the summer I found myself working 12+ hours a day.

    Marv and Bard air units....
  3. Thread: Info On JLL

    by jtel
    Replies
    29
    Views
    2,650

    I believe JLL literally uses the terms mobile and...

    I believe JLL literally uses the terms mobile and stationary engineers to describe employees that move from place to place or stays in one compound or building.
  4. Replies
    3
    Views
    1,035

    Thanks. I found out last week this is in a non...

    Thanks. I found out last week this is in a non union shop.
  5. CT employers are usually looking to see that you...

    CT employers are usually looking to see that you are licensed or working towards it so get a hold of the State licensing bureau and look into that.

    Looks like there are some jobs on your local CL...
  6. Replies
    3
    Views
    1,035

    No one?

    No one?
  7. Replies
    3
    Views
    1,035

    Coca Cola Refrigeration Pay?

    Anyone know what they pay for a refer tech - not a cooler tech? I know there are two classifications there and refer tech pays more but I can't find a contract online anywhere but Vancouver.

    Thanks
  8. Thread: Work pants

    by jtel
    Replies
    84
    Views
    7,752

    I have a couple of pair of 'rip stop' work pants...

    I have a couple of pair of 'rip stop' work pants I bought at Walmart. Great for climbing lots of room.

    Indestructible and comfortable after a few washing's.
  9. Replies
    5
    Views
    1,184

    Bay State Cooling in Bridgewater, MA is looking...

    Bay State Cooling in Bridgewater, MA is looking for a supermarket tech right now. They do BJs Wholesales around the area. REECO in Woburn, MA does commercial & industrial refrigeration and I...
  10. Replies
    23
    Views
    1,902

    Just a parting thought. The person saying this...

    Just a parting thought. The person saying this wasn't a safety issue took me to an account when I first got here to pm a split system where the condenser was on the roof.

    They threw up a fully...
  11. Replies
    23
    Views
    1,902

    The meeting was surreal. I couldn't believe what...

    The meeting was surreal. I couldn't believe what I was hearing. About halfway through I finally realized this was not about anything but putting me in my place and having me do as I am told.

    Here...
  12. Replies
    23
    Views
    1,902

    My boss got to the owner. It was a two on one...

    My boss got to the owner. It was a two on one ambush.

    I have an offer already. I'm out.
  13. Replies
    34
    Views
    6,299

    Clear your head get yourself well positioned and...

    Clear your head get yourself well positioned and think it through writing down all the data you grab and see what jumps off the page. Obviously head pressure is low and suction is high. Bad valves?...
  14. Replies
    34
    Views
    6,299

    248 seems pretty low for 100 degree ambient. 100...

    248 seems pretty low for 100 degree ambient. 100 is definitely high. Amp draw should be low if the valves are going but the pressures do point to that without more data.

    Where is that...
  15. Replies
    23
    Views
    1,902

    Agreed the new pressure control is pretty useless...

    Agreed the new pressure control is pretty useless as it can't be read for adjustments etc.
    I set it before I wired it in and that's where it'll stay.

    Water has been dripping on this equipment...
  16. Replies
    23
    Views
    1,902

    The customer walked away from me when I attempted...

    The customer walked away from me when I attempted to explain the access and safety issues.
  17. Replies
    23
    Views
    1,902

    Poor Access & Safety Issues

    I'm working on a walk in freezer that has multiple issues. When I first looked at the location I said no way but was told 'I had to service it regardless'.

    The condenser is located on top of the...
  18. Replies
    51
    Views
    8,284

    I've never worked on this before and we are still...

    I've never worked on this before and we are still waiting for the compressor.

    I asked ThermoScientific if there was a preference for which gas is weighed in first and they said 404a first then...
  19. Replies
    51
    Views
    8,284

    I am absolutely sure that this is a single...

    I am absolutely sure that this is a single system. At one point I went out to double check that and since then I've been on the phone with the manufacturer several times.

    This is not much bigger...
  20. Replies
    51
    Views
    8,284

    Blood Bank Freezer w/2 Refrigerants By Design

    I've got a customer (a Hospital) with a small blood freezer which takes both 404 and 134 per the manufacturer. we were all scratching our heads at this one.

    It's made by Thermo Scientific. I've...
  21. Thread: SMAN 3

    by jtel
    Replies
    32
    Views
    4,769

    The high side pipe clamp on my SMAN-3 broke in...

    The high side pipe clamp on my SMAN-3 broke in two today (I had an extra) and there is a leak on the high side also.

    Less than a year old and very well taken care of. Not happy.
  22. Thread: Unethical?

    by jtel
    Replies
    25
    Views
    2,648

    Flat rate companies feed the techs from sales so...

    Flat rate companies feed the techs from sales so you know that's going on with them. Some are no sales no pay. I don't know how they get away with no per hour wage.

    I've never seen a competent...
  23. Replies
    15
    Views
    1,747

    Controls, controls, controls. Better working...

    Controls, controls, controls. Better working conditions by far, better pay etc etc

    Take that opportunity. If you don't like it you can go resi very easily but if you went resi that type of an...
  24. Replies
    70
    Views
    5,753

    There are plenty of companies out there who would...

    There are plenty of companies out there who would have done time if they were a person.

    I have some stories and I'm sure most techs have heard stories also.
  25. Replies
    7
    Views
    1,202

    I realize that there is not much bandwidth needed...

    I realize that there is not much bandwidth needed for these systems but BACnet is rather dated and that wire is brutal. I haven't seen it but someone out there must have a system that uses ethernet...