  1. Thread: Replace TXV?

    by Retread
    Replies
    1
    Views
    210

    Replace TXV?

    I have a 5 ton system on a 2300 sq ft home I am working on. I don't do homes normally mostly roof top units.

    Suction pressure is going back and forth between 60 and 67 psi.
    High side moving back...
  2. Replies
    71
    Views
    3,049

    When you find another job (and you should) call...

    When you find another job (and you should) call the labor board they will make sure you get back pay for all the ot you worked. You will also be doing the next guy a favor. If they have that many...
  3. Replies
    22
    Views
    1,081

    We had a couple of brand new Lennox package units...

    We had a couple of brand new Lennox package units with single phase copeland compressors that would not start. Put a hard start kit on and the they started and ran fine. After a day did not need...
  4. Thread: Questions??

    by Retread
    Replies
    34
    Views
    3,002

    Look for warm areas for this trade. OKC again had...

    Look for warm areas for this trade. OKC again had the lowest unemployment rate of any large city less than 5% now 21 out of the last 25 months. He will need to get a state licence that should not be...
  5. Replies
    31
    Views
    8,053

    Lennox is selling off Service Experts no buyer...

    Lennox is selling off Service Experts no buyer announced just intent to sell.
  6. Replies
    535
    Views
    37,969

    They don't have to give you a reason to fire you...

    They don't have to give you a reason to fire you but if they don't they cant then claim a reason to deny unemployment benefits. One reason that has been mentioned for not being union in a right to...
  7. Replies
    23
    Views
    2,850

    I am blowing oil from my vac pump also but...

    I am blowing oil from my vac pump also but thought it was just due to the volume of gas coming through the pump and picking up the oil in the vacume pump. I had not even thought I might be pulling...
  8. Replies
    27
    Views
    4,499

    What he said. I had one start at normal amps...

    What he said. I had one start at normal amps then climb as it ran until it tripped. Boss thought I was crazy changing compressor but had no other ideas, then was happy when it fixed the issue.
  9. Thread: Manifold hoses

    by Retread
    Replies
    24
    Views
    2,567

    I use the black hoses from NRP and add the low...

    I use the black hoses from NRP and add the low loss or anti-blowback fittings that you add. Then when pulling vacuum or recovering I can take it off and go straight to the core removal tool. The...
  10. Replies
    17
    Views
    2,497

    When you say technical college I am not sure what...

    When you say technical college I am not sure what you have found. In Oklahoma one of the most respected schools is OSU Tech, a branch of the university that offers an Associates degree. Some of the...
  11. Thread: Lennox 40 ton?

    by Retread
    Replies
    15
    Views
    2,043

    how sure are you the condenser is clean? If you...

    how sure are you the condenser is clean? If you did not wash it I would start there. Helped a tech the other day by phone where he weighed in the charge on a coil that looked clean but when he...
  12. Replies
    7
    Views
    1,102

    you might want to consider used especially if you...

    you might want to consider used especially if you are just starting up a company. Lower overhead greater chance of survival in first few years. Also Ford is rumored to be coming out with the full...
  13. Replies
    15
    Views
    1,339

    I have seen them that way before. On one job I...

    I have seen them that way before. On one job I had to inspect the work of the installer for a chain. It was an above ceiling grid install and the specs called for the opening to be on the top of...
  14. Replies
    11
    Views
    1,622

    And they ran the wire over the blower bracket...

    And they ran the wire over the blower bracket between the top of the unit and the bracket. After a while the insulation on the top goes then the wire insulation and a nice short to ground on the...
  15. Replies
    11
    Views
    1,622

    check to see if your transformer is connected to...

    check to see if your transformer is connected to the 208v or 240v tap if it a 208/240v unit. They come from the factory on the 240v tap and if you have 208v it can make the contactor chatter.
  16. Replies
    18
    Views
    2,192

    on some compressors you can tell by the paper the...

    on some compressors you can tell by the paper the label is made of. When it gets too hot the label turns brown. I know that is true on some Lennox units. When they see that it can void the...
  17. Replies
    10
    Views
    1,508

    I use a pocket notebook you can get a office...

    I use a pocket notebook you can get a office depot or the like. Has a band around it last longer and not as likely to get messed up. still fits in shirt pocket but larger than the supply house...
  18. Replies
    95
    Views
    10,580

    no steel tank like nitro.

    no steel tank like nitro.
  19. Replies
    95
    Views
    10,580

    The United Refrigeration here carries the CO2 for...

    The United Refrigeration here carries the CO2 for those of you who are looking for it.
  20. Replies
    12
    Views
    1,515

    I have worked on the billable hour before and It...

    I have worked on the billable hour before and It can work out. We billed all our drive time. so I was possible to charge 14 hours for 12 worked. For example drive 45 min to area and have two calls...
  21. Replies
    2
    Views
    762

    I will look at mine and see is that is the case...

    I will look at mine and see is that is the case with the 902 good to know thanks.

    I finally found that yes the comm wire went to the roof like I thought but the Building Automation guy said now...
  22. Thread: Which tool

    by Retread
    Replies
    11
    Views
    1,032

    What he said.

    What he said.
  23. Replies
    2
    Views
    762

    Odd reading with my Fluke 902

    I was working with the building automation guy today trouble shooting some noise in the comm circuit of the EMS system. To find which of the two comm wires goes from the lighting panel to the EMS...
  24. Replies
    32
    Views
    3,878

    It's not legal. over 40 hours worked must be...

    It's not legal. over 40 hours worked must be paid at time and a half unless you are on Salary. Also employer to get out of OT salaried person must spend something like 60% of their time in...
  25. Replies
    12
    Views
    893

    sounds like the drier. look for the restriction...

    sounds like the drier. look for the restriction where the ice starts. If it was the condenser part of it should be iced.