Search:

Type: Posts; User: t527ed

Page 1 of 20 1 2 3 4

Search: Search took 0.09 seconds.

  1. Replies
    21
    Views
    748

    :ditto:

    :ditto:
  2. Replies
    4
    Views
    206

    pull the cold air off the floor. :.02:

    pull the cold air off the floor. :.02:
  3. Replies
    16
    Views
    577

    if the manual states it must be installed as...

    if the manual states it must be installed as direct vent then that's what needs to be done.
    we have NEVER installed a 90+ furnace as a single pipe system, i don't want contaminated house air being...
  4. Replies
    6
    Views
    203

    if they are going to use filter grills then make...

    if they are going to use filter grills then make sure ALL return ducting back to furnace is 100% air tight. if not you will be pulling dirt into system after filter.
    i prefer to use filter rack or...
  5. Replies
    11
    Views
    330

    if its a single stage unit and w915 jumper on...

    if its a single stage unit and w915 jumper on board is in place it will run blower at 2nd stage settings no matter what Y terminal it is wired to.
  6. Replies
    39
    Views
    814

    nobody is going to rake him over the coals for...

    nobody is going to rake him over the coals for doing it.

    EVERYONE is going to rake him over the coals for talking about doing it. :whistle:
  7. Replies
    7
    Views
    312

    what tonnage?

    what tonnage?
  8. Replies
    5
    Views
    220

    water was leaking out of t instead of backing up...

    water was leaking out of t instead of backing up into pan to trip safety.
    drain lines get dirty and need to be maintained, yours is undersized and should be replaced with full size 3/4" pvc.
  9. Replies
    22
    Views
    1,208

    to use a 13 seer unit with an old cap tube evap...

    to use a 13 seer unit with an old cap tube evap coil it will have to be grossly overcharged to get the liquid pressure up high enough to feed thru the cap tube.
    it will work but it won't be right...
  10. in over 40 years i have never seen them for...

    in over 40 years i have never seen them for residential use.
    a true split system would be much more efficient.
  11. it may work with no problems, could be nothing...

    it may work with no problems, could be nothing but a big headache.
    depending on the system, coil location, ease of changing line set etc.. smart money would be replacing complete system.
  12. Replies
    6
    Views
    304

    could not find exact model # but every amana...

    could not find exact model # but every amana model with a 5 in it was a 5 ton unit.

    any #s you can read on compressor?
  13. i don't understand why you keep referring to...

    i don't understand why you keep referring to Trane as a "premium" brand ???

    you may have paid a lot for it but price alone does not equal quality.
  14. any part on that system could fail, it's a...

    any part on that system could fail, it's a machine.
    not worth worrying about.
  15. #1

    #1
  16. Lennox had some weird serial #s up until the...

    Lennox had some weird serial #s up until the 70's, that looks like one of them.

    i would plan on changing the lines.
  17. Replies
    41
    Views
    2,114

    i sent a loose dog on his way yelping the same...

    i sent a loose dog on his way yelping the same way once.
  18. as the installer and the guy who has to go back...

    as the installer and the guy who has to go back and fix it when it breaks i have always been in the habit of looking for stuff that could be a problem.
    lines touching and rubbing through each other...
  19. Replies
    4
    Views
    300

    package unit will be fully charged from factory....

    package unit will be fully charged from factory.
    needs to be checked on start up in case of a leak.
  20. Replies
    4
    Views
    300

    most units ship with charge for 15' of lineset...

    most units ship with charge for 15' of lineset and matching coil.
    installer must balance charge at start up.
  21. Replies
    1
    Views
    194

    with what it would cost to run the well it would...

    with what it would cost to run the well it would never pay for itself unless you are already watering landscape as much as a/c runs.

    it would not harm a/c as long as you are not restricting air...
  22. contact Trane directly as the consumer and give...

    contact Trane directly as the consumer and give them that argument.
    stop back and let us know how you make out.
    i don't disagree with you and i really don't like Trane equipment so i'm not...
  23. did you close off the vent when you sucked out...

    did you close off the vent when you sucked out with shop vac?
  24. installer should have checked for any rub points...

    installer should have checked for any rub points at start up.

    Trane's obligation is to provide a replacement part.
  25. Replies
    5
    Views
    258

    low speed for heat, high speed for cooling. it...

    low speed for heat, high speed for cooling. it starts on whatever speed it is going to run on.
Results 1 to 25 of 500
Page 1 of 20 1 2 3 4
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event