  1. Replies
    40
    Views
    4,313

    the rigid tool warranty is a joke, my company...

    the rigid tool warranty is a joke, my company supplied my van with the 24v line of rigid tools, hammer drill, saws all, impact, flashlight, skill saw. the tools are OK, but the battery are terrible,...
  2. Replies
    41
    Views
    5,569

    i am interested in getting a set of digital...

    i am interested in getting a set of digital gauges and was wondering why you went with the digi cools, just wondering what features it had that you liked, im not trying to start a fight between...
  3. Replies
    12
    Views
    6,052

    we use the t&P port on the top with a 3/4 brass...

    we use the t&P port on the top with a 3/4 brass nipple to a brass tee, then pull the drain out ant use a 3/4 brass nipple and tee there too it has never given us problems
  4. Replies
    2
    Views
    726

    Has any one seen or used this?

    I was at my local Supply house dropping my combustion analyzer off for recalibration and the TPI guy was there showing this bearing/vibration tester off, i was pretty impressed with it
    ...
  5. Replies
    14
    Views
    1,662

    i am looking into a new multimeter, and ive herd...

    i am looking into a new multimeter, and ive herd fluke is now made in china as of 2002 and the quality isnt as good is there any truth to this?
  6. Thread: Leaky Loop!!!

    by norm36
    Replies
    10
    Views
    2,330

    i have used loop conditioner with success but...

    i have used loop conditioner with success but only on small leaks. Its worth a shot because it seems to me to redo a loop is much harder to do for some reason like landscaping barns sheds garages....
  7. a little heat or a 1/2 npt bottoming tap

    a little heat or a 1/2 npt bottoming tap
  8. Replies
    5
    Views
    1,656

    the third pic is an infloor system ran off a...

    the third pic is an infloor system ran off a crown boiler(boiler was installed by the homeowner)

    fourth pic is a infloor job in a customers air plane hanger, its ran off a 50gal high output...
  9. Replies
    5
    Views
    1,656

    the first pic is a house with lots of land,the...

    the first pic is a house with lots of land,the second pic is a residential house, there is a air handler then the domestic hot water tank then the desuperheater tank, then a 60gal storage tank for...
  10. Thread: first post

    by norm36
    Replies
    15
    Views
    2,573

    looks good but is that pipe in front of the pump...

    looks good but is that pipe in front of the pump it could be a pain to service if the pump fails,it might be the angle of your photo keep up the good work
  11. Thread: water damage

    by norm36
    Replies
    3
    Views
    1,506

    water damage

    i got a no cooling call last summer i walk down the stairs and i can see a water line all the way around the unfinished basement walls a foot up, and on the geothermal heat pump access panel so i...
  12. Replies
    5
    Views
    1,656

    a few jobs ive done

    just a few jobs ive done
  13. Replies
    14
    Views
    3,462

    i service rental furnaces for a large Canadian...

    i service rental furnaces for a large Canadian company and they put those filters in and man its unbelievable how bad they can get, and the customers dot care cause its not there job to change it lol
  14. Replies
    17
    Views
    3,437

    i love thoes rehau pro balance manifolds for the...

    i love thoes rehau pro balance manifolds for the in floor more$$$ but worth it
  15. Replies
    6
    Views
    1,967

    well at least you cleaned it up looks great now

    well at least you cleaned it up looks great now
  16. Replies
    9
    Views
    2,318

    wow it sucks when 6 for 6 where crooks it makes...

    wow it sucks when 6 for 6 where crooks it makes every hvac service tech look bad
  17. Replies
    3
    Views
    2,327

    We have had climate master units that have had...

    We have had climate master units that have had leaky evap coils from new, and now the new warranty coils are not epoxy coated, also have has a bad run on txv's on water to water tranquility units,...
Results 1 to 17 of 18