  1. Manitowoc has some financing options available on...

    Manitowoc has some financing options available on their web site. The new indiago units have a lot of things you can check and read out to help diagnose in the future after the three year parts and...
  2. Replies
    23
    Views
    6,514

    Guys, he jumpered the float switch. This...

    Guys, he jumpered the float switch. This eliminates any water issues and goes back to a board issue or a connection. I would agree with craig1 and check the board. You have jumped the wire...
  3. Replies
    17
    Views
    1,516

    There is also a drain for the head on the I...

    There is also a drain for the head on the I series, different from the pump out drain. There is a service communicator on it. So the heads have two different drains. The I series are a completely...
  4. Replies
    13
    Views
    1,771

    Post some pics, this would help us all on some...

    Post some pics, this would help us all on some ideas. There are many options that can be applied.
  5. Thread: Kold Draft

    by J_Bridge
    Replies
    7
    Views
    1,519

    There are a lot of the newer style kold drafts...

    There are a lot of the newer style kold drafts and the older ones that we work on. Not a big fan of them, I don't see why an ice machine manufacturer can't get their charge properly. The...
  6. Replies
    30
    Views
    3,660

    I have been doing this for over 13 years and my...

    I have been doing this for over 13 years and my company for over 35 years and we have never had a tstat in the coil on a WIC. But let me clarify what I am calling off cycle defrost. We always...
  7. Replies
    30
    Views
    3,660

    Stick a tstat of a walk in cooler in the coil?...

    Stick a tstat of a walk in cooler in the coil? What? You should never do that! Return air is where the bulb should be at, t-stat set to cut out at 32 degres in ice water(calibrate). The numbers...
  8. Replies
    9
    Views
    1,584

    Isn't this showing 4 defrost a day at 40 minutes...

    Isn't this showing 4 defrost a day at 40 minutes long? one at 6:45, 12:45, 6:45 and 12:00? Yeah that is a problem, 4th defrost needs to changed to 24:45 to be inlign with the others that are all 6...
  9. Replies
    7
    Views
    1,319

    Go TXV, it will repond better and you can know...

    Go TXV, it will repond better and you can know with a full sight glass you are properly charged. Plus you will get more precise adjustment from the valve. pump unit down, install txv, change drier,...
  10. Replies
    28
    Views
    3,875

    Just on the outlet from what was understanding...

    Just on the outlet from what was understanding from sporlan
  11. Replies
    6
    Views
    1,075

    Ok here it is. 20 degree superheat at the...

    Ok here it is. 20 degree superheat at the compressor during a load situation and no lowere. This ensures that at night under low load we still have superheat at the compressor and not a saturation...
  12. Replies
    28
    Views
    3,875

    Sporlan C052capt-tt-hh drier is specificall...

    Sporlan C052capt-tt-hh drier is specificall designed for cap tube systems with wax issues. It has carbon, solid core, strainer and felt pad. Sporlan made it for these specific issues.

    And...
  13. Replies
    10
    Views
    1,390

    I agree, if you have a compressor or evaporator...

    I agree, if you have a compressor or evaporator on a unit that is out of warranty. Highly recommend replacement, if they do repair I quote everything, txv's, head master,
    hot gas valves. You...
  14. Replies
    34
    Views
    4,567

    Oh yeah I didn't state this yet. My company I...

    Oh yeah I didn't state this yet. My company I work for is Authorized with every mfg. for commercial refrigeration, so we do a lot of warranty work. We have had in place for 5 years now a contract...
  15. Replies
    17
    Views
    2,565

    I know the customer doesn't like to remove the...

    I know the customer doesn't like to remove the ice, but to do the job right and prevent future failures this is what we require. If not it is noted and that way we aren't responsible or liable. Now...
  16. Thread: Kold Draft

    by J_Bridge
    Replies
    7
    Views
    1,519

    Kold Draft

    Has anybody else had the pleasure of working on these new style Kold Drafts that have had a surge on the market? If so how do you feel about all there issues? I wish they would figure out how to...
  17. Replies
    43
    Views
    6,026

    Thats the ones I have seen and used, thanks for...

    Thats the ones I have seen and used, thanks for the link. These are perfect, I have seem some mylar style as well. But this site looks great!
  18. Replies
    43
    Views
    6,026

    sorry for my typos, was using a smart phone and...

    sorry for my typos, was using a smart phone and it was late.
  19. Replies
    34
    Views
    4,567

    Scotsman definately has a long hold time,...

    Scotsman definately has a long hold time, Manitowoc has after hours help to on warranty calls. you just have to wait a long time. but so do the other 4 companies. And I haven't had to wait to long...
  20. Should have posted this in the ice machine forum,...

    Should have posted this in the ice machine forum, what are you trying to calibrate? I have worked on several of them, new and old. The gentlman at the factory is very knowledgable. I printed a...
  21. Replies
    34
    Views
    4,567

    Never had issues out of Manitowoc either, we are...

    Never had issues out of Manitowoc either, we are a csr and our regional service manager is great. You have to communicate with them, especially your regional service manager about special...
  22. Replies
    6
    Views
    1,075

    I will find out. I know this is to ensure all...

    I will find out. I know this is to ensure all the refrigerant is boiled off, but will get more details.
  23. Replies
    28
    Views
    3,875

    Last I checked sporland doesn't use a pad. I...

    Last I checked sporland doesn't use a pad. I have never had an issue with that, I will check with my rep tomorrow on that though.
  24. Replies
    6
    Views
    1,075

    Welling service is correct, box needs to close to...

    Welling service is correct, box needs to close to temp. 8-10 frz and 10-12 on coolers, but make sure that at your comp you are no lower than 25 degrees. That is a coprland spec, you can go 20 but...
  25. Replies
    10
    Views
    1,390

    Why would you ever use a used compressor? I...

    Why would you ever use a used compressor? I work on 7 or cubers a week and woukd never jeporadize my customer by installing used parts, not worth the hassel of unloading my van, recovering...
Results 1 to 25 of 39