Search:

Type: Posts; User: vikings

Search: Search took 0.00 seconds.

  1. Thread: True cooler

    by vikings
    Replies
    12
    Views
    1,822

    Yes, there is slight play. We have done this...

    Yes, there is slight play. We have done this about ten times with success. Good luck.
  2. Thread: True cooler

    by vikings
    Replies
    12
    Views
    1,822

    This is what you have to do. You need to raise...

    This is what you have to do. You need to raise the evap as high as it will go above the pan. These units were manufactured with the evap down too low - causing these leaks to occur. Do this and...
  3. Replies
    9
    Views
    791

    That is the best way - however, we did remote a...

    That is the best way - however, we did remote a system about four years ago and kept the cap tube. We never had a problem.
  4. Replies
    36
    Views
    2,221

    Only one way to repair this - replace the whole...

    Only one way to repair this - replace the whole rec.
  5. Thread: UV Lights

    by vikings
    Replies
    2
    Views
    591

    Do these lights really work, and if so what do...

    Do these lights really work, and if so what do they do?
  6. Replies
    12
    Views
    1,130

    We have a three drawer, 6 drawer, 4 drawer and a...

    We have a three drawer, 6 drawer, 4 drawer and a three door beer bottle cooler running off of the same compressor. Each box has either one or two evaps with 1/4 ton expansion valves - with the...
  7. Replies
    113
    Views
    8,765

    Yes, we are repairing alot of these in PA. We...

    Yes, we are repairing alot of these in PA. We only replace the heat exchangers, not the repair kit. More money and easier to do. Even if the heat x is not cracked - replace the heat x.
  8. Replies
    2
    Views
    797

    What is the going rate for a residential HVAC...

    What is the going rate for a residential HVAC salesman. Is it only commission or both salary and commission. What is the % of commission. Also, if anyone knows a salesman in the south NJ area...
  9. Replies
    51
    Views
    5,234

    You guys, The question should be how much are...

    You guys,

    The question should be how much are you worth to the company and how dedicated are you?. Thats how much you should be making. Get real
  10. Replies
    13
    Views
    1,119

    Stretch out you check valve spring - you are...

    Stretch out you check valve spring - you are losing water passed the CV.
  11. Replies
    23
    Views
    1,903

    You could install a door closer or curtain. ...

    You could install a door closer or curtain. Kitchen people do not understand the concept of closing the door!
  12. Replies
    15
    Views
    1,349

    Thanks guys for all of your help. We sometimes...

    Thanks guys for all of your help. We sometimes add recievers and TXV's with those odd ball applications.
  13. Replies
    15
    Views
    1,349

    What is everyone using for a replacement for r-12...

    What is everyone using for a replacement for r-12 for a freezer? 409 or hot shot?
  14. Thread: Friedrich PTHP

    by vikings
    Replies
    4
    Views
    1,823

    These units are cheap and GE is better. However,...

    These units are cheap and GE is better. However, you can make more money on repairs with the Freds.
Results 1 to 14 of 14