  1. Replies
    30
    Views
    1,918

    rc - all original equip. read my last post on...

    rc - all original equip. read my last post on the facts
  2. Replies
    30
    Views
    1,918

    jay guy, I agree. here is the facts ...

    jay guy, I agree. here is the facts

    compressor starts, head pegs, suction goes into vacume (all in a second or two) pressure switch trips. pull out about 17 lbs of r-22, replace filter (checked...
  3. Replies
    30
    Views
    1,918

    weighed back in 17lbs, (factory) and unit ran...

    weighed back in 17lbs, (factory) and unit ran great. only diff. was new filter.
  4. Replies
    30
    Views
    1,918

    The question was raised... how much was I pulling...

    The question was raised... how much was I pulling out on the repairs. it was right around or just under factory charge, thats right. back to the beginning.
  5. Replies
    30
    Views
    1,918

    Ok, i'm picking up what you are throwing down. ...

    Ok, i'm picking up what you are throwing down. So it will peg and do what I'm saying with a plugged filter and too much ref. So the guy before me started seeing a prob. and added. and then after...
  6. Replies
    30
    Views
    1,918

    very interesting cm! I deffinatly will check...

    very interesting cm! I deffinatly will check into that. Could you explain more about oil at the bottom of the compressor?
  7. Replies
    30
    Views
    1,918

    I get the fact what too much does. I'm wondering...

    I get the fact what too much does. I'm wondering why you say a plugged liquid line filter wouldn't cause what I think in normal restriction pressures. head peggs out and suction goes down to a...
  8. Replies
    30
    Views
    1,918

    why wouldn't a restriction in the luquid line...

    why wouldn't a restriction in the luquid line cause a high head. agian, head pegs and suction tanks
  9. Replies
    30
    Views
    1,918

    The first one, it started with a leak and when I...

    The first one, it started with a leak and when I changed the filter it was plugged. repaired unit, all was fine, press. amp. etc. 4-hours later, compressor shrted out.

    The other situations....
  10. Replies
    30
    Views
    1,918

    Interesting, I took over a building this spring...

    Interesting, I took over a building this spring and they all are ycd 300. I replaced 4- liquid line driers (plugged) and two compressors. The chain of events seem to be as follows, plugging of...
  11. Thread: In house design

    by tmk
    Replies
    16
    Views
    1,202

    I recieved an answer for the owner. He is out of...

    I recieved an answer for the owner. He is out of the county and will be returning on the 23rd. He said her will get me all the info at that time.

    Thanks guys, hang in there.
  12. Thread: In house design

    by tmk
    Replies
    16
    Views
    1,202

    Once I get the plan, or manual they put together...

    Once I get the plan, or manual they put together I should have all the info. Great idea, I'll take a snap shot of this as well. I also left a message asking for water temp requirments as well. I...
  13. Thread: In house design

    by tmk
    Replies
    16
    Views
    1,202

    Hey Guys, thanks for the response. I left a...

    Hey Guys, thanks for the response. I left a message for this guy asking if he would let me take their drawings from them. Haven't heard back. I'll call agian Monday if anything I'll just grab...
  14. Thread: In house design

    by tmk
    Replies
    16
    Views
    1,202

    ok, it is a wierd set up. tell you what, I'll go...

    ok, it is a wierd set up. tell you what, I'll go there today to get it fresh agian. The cooling part goes for the machine cooling. now the the summer they reverse the water flow. it's wierd. I'll...
  15. Thread: In house design

    by tmk
    Replies
    16
    Views
    1,202

    vac. Each plate has a grunfos I believe 15-42....

    vac. Each plate has a grunfos I believe 15-42. (I'll have to verify this). So I believe this should be good.

    Dowadda - That was my first question to them when I saw it. The answer was, yes they...
  16. Thread: In house design

    by tmk
    Replies
    16
    Views
    1,202

    They all have manual switching. Which will need...

    They all have manual switching. Which will need to be addressed as well. However it still happens even with one running.
  17. Thread: In house design

    by tmk
    Replies
    16
    Views
    1,202

    Equipment: Copeland Compressor...

    Equipment:
    Copeland Compressor
    MO:ZR4OK1-PFV-230
    SE:90G130160

    Condenser - Flat Plate TEV: Sporlan KT-43VCP100
    MO:CZA SE:D020AC34302002
    Evap - Flat Plate
    MO:CH3A SE:A030AC34302003
  18. Replies
    14
    Views
    1,041

    Comf. master. i'm sorry you lost faith. maybe...

    Comf. master. i'm sorry you lost faith. maybe it's because you where left starved. give the bible a chance. if you truely want too know you will get the answer. Matt. 7:7
  19. Replies
    11
    Views
    790

    Why would you fast? because of tradition of man...

    Why would you fast? because of tradition of man or because what you found in the bible says you should?
  20. Replies
    8
    Views
    1,075

    that is what I'm leaning towards, I thought I...

    that is what I'm leaning towards, I thought I would toss my situation out there just to see if I'm looking in the right direction or if there was something else.

    Thanks alot New B.
  21. Replies
    8
    Views
    1,075

    Thats the thing, I can remove some ref. how ever...

    Thats the thing, I can remove some ref. how ever it's like the txv doesn't compensate. My sub cooling changes by a degree or five. the suction gets to low and then starts bouncing off of low...
  22. Replies
    8
    Views
    1,075

    I've been looking at a Cooler for a friend. ...

    I've been looking at a Cooler for a friend.
    It's a Knight. MO:d6ost SE:39140.

    This was a R12 to MP39 conversion. I repaired a leak in this system by a flare nut at the Expansion valve. When...
  23. Thread: Snow / Carrier

    by tmk
    Replies
    15
    Views
    1,320

    That is my nest step, I just thought I would toss...

    That is my nest step, I just thought I would toss it out hear to see if I was alone on this. the back plate where the terminal strip is has tons of pre-drilled holes and of course that is open to...
  24. Thread: Snow / Carrier

    by tmk
    Replies
    15
    Views
    1,320

    I should add all these units are brand new. I...

    I should add all these units are brand new. I haven't seen them any where else. I found them on a new building and another with new replacements
  25. Thread: Snow / Carrier

    by tmk
    Replies
    15
    Views
    1,320

    Nice!!! you can come and get all the snow you...

    Nice!!! you can come and get all the snow you want, just for the experience!

    I could have something to do with the 500 holes that are punched out on the back panel which is open to the condenser...
Results 1 to 25 of 49
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event