    Google "california labor laws overtime hours"

    Google "california labor laws overtime hours"

    Keep records of your hours and dates.

    You can hire an attorney and get some backpay.

    Call the State Labor Board first if you want.

    There are...
  2. Thread: carrier clo

    by uhPrintUs
    Replies
    16
    Views
    1,545

    Cond Fan Motor

    I'd recommend checking for condenser fan motor bearing play. If the shaft moves side to side even a tiny amount, it will overheat and shut off after running a few hours on a hot day.

    Regarding...
  3. Thread: SMAN 3

    by uhPrintUs
    Replies
    32
    Views
    4,709

    SMAN 4

    http://www.trutechtools.com/SMAN4
  4. Replies
    35
    Views
    5,395

    We cannot be TOO careful!

    I have a friend, who fortunately escaped injury, who was doing pre-start-up checks inside a larger air handler. He had verified with his meter the power was off. He had just finished working at the...
  5. Gas Ballast

    http://www.yellowjacket.com/sites/default/files/product_manuals/142993_D%20English.pdf

    Per the info at Ritchie Engineering website in link above, the gas ballast should remain open until 1,000 -...
  6. Replies
    45
    Views
    3,581

    Portable Sunshine

    http://streamlight.com/education/guide.aspx

    Everyone has their own likes & dislikes when it comes to flashlights. An air balancer friend of mine had a Streamlight flashlight that impressed me so I...
  7. Replies
    11
    Views
    1,269

    Regarding inverted traps---

    Just remember that the purpose of an inverted trap is to prevent the liquid refrigerant from draining by gravity from the coil into the compressor during the off cycle.

    So, if the air handler is...
  8. Hmmmm

    So, the seasoned tech blames the problem on you for not checking the compressor terminals, but he didn't check the terminals either until after he was ready to button things up and walk away!

    And...
  9. Questions about Fieldpiece SMAN3 digital manifold

    I've never used Fieldpiece instruments.

    1. With the SMAN3, if a person wanted to measure temperature on a pipe larger than the pipe clamp is suitable for, is it possible to plug a Fluke temp...
  10. Replies
    7
    Views
    868

    How much is "a little bit"?

    If the kink causes "a little bit" of pressure drop, it MIGHT cause trouble on the hottest days.

    Pressure drop in the liquid line reduces subcooling, sometimes to the point of flashing liquid into...
  11. Replies
    8
    Views
    1,829

    So you have 47 degrees of superheat at the...

    So you have 47 degrees of superheat at the compressor. That seems pretty high. I'd open the TXV to bring the SH down, which will also increase the suction pressure and provide more capacity out of...
  12. If he had done the job correctly the first time,...

    If he had done the job correctly the first time, replacing the refrigerant would be unnecessary. I agree with all of the above. Now the entire system needs to be evacuated, not simply the line set...
  13. Replies
    3
    Views
    601

    Time for a second opinion

    A. A leak can lead to a compressor "failure", but if your compressor worked long enough to produce a cool suction line as you described, my "guess" is that the compressor is ok. Compressor...
  14. Replies
    14
    Views
    2,388

    Refrigerant line whistling may also be caused by...

    Refrigerant line whistling may also be caused by excessive velocity, which is caused by undersized lines.

    If the line is kinked, such as at the bend where the line enters or leaves the wall, this...
  15. Osmotic pressure difference causes the problem

    Google "Examples of osmosis".

    When you read a definition of osmosis, don't stop reading after the first couple of sentences. Keep reading to understand what it means.

    The semi-permeable...
  16. Replies
    51
    Views
    9,509

    ???

    I'm not sure what you mean by the phrase "Head pressure: 118F 83 + 35 = 118F"

    Head pressure and High Side Pressure are the same, and pressure is in psig, not degrees F.

    You indicate the...
  17. Replies
    5
    Views
    1,533

    Yellow Jacket Flexible Steel Hoses!

    Yellow Jacket Flexible Steel Hoses!

    Order the length and diameter you want, then treat them with care and don't loan them out. Most of the times I've loaned mine, even to those I thought would...
  18. Replies
    13
    Views
    2,629

    What's the source of that information?

    I may agree with the point you're trying to make, but I like to be careful before spreading false information, so I did some searching and I cannot find an organization called "United Nations...
  19. Liebert XDC Chiller Pump "Loss of Flow" Issues

    How many people are having flow loss issues with the Liebert XDC Chillers that use R-407C to cool the pumped R-134a? Also, is there anyone who has NEVER had this occur?

    We've determined multiple...
  20. Replies
    2
    Views
    1,495

    I see you posted your question almost two months...

    I see you posted your question almost two months ago but received no responses. Have you solved the problem yet?

    What model is the equipment?

    Does the controller allow you to set the humidity...
  21. Thread: micron gauge

    by uhPrintUs
    Replies
    68
    Views
    8,134

    I agree regarding the Thermal and cold weather....

    I agree regarding the Thermal and cold weather. It took me awhile to figure out the problem and it was quite frustrating to arrive at the job site on mornings when the temp was around 40 degrees F...
  22. Replies
    10
    Views
    1,719

    I was told the fittings are solderless and are...

    I was told the fittings are solderless and are not shark-bites
  23. Replies
    10
    Views
    1,719

    What kind of fitting is this?

    223472
    These fittings were seen on R-410A discharge & liquid lines to join soft tubing for a Liebert rooftop condenser. The system has been operating for a few months, including during some 100+...
  24. Replies
    4
    Views
    689

    What kind of fitting is this?

    These fittings were seen on R-410A discharge & liquid lines to join soft tubing to a rooftop Liebert condenser that has been in operation a few months, including some 100+ degree weather.

    What...
  25. r22eric, Since this is your first post, I...

    r22eric,

    Since this is your first post, I suppose you don't understand how the forums work, because you should start a new thread instead of beginning a new topic in the middle of another thread....
Results 1 to 25 of 51
Page 1 of 3 1 2 3
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine
Comfortech365 Virtual Event