  1. Replies
    30
    Views
    1,421

    Without anything isolating it from the rest of...

    Without anything isolating it from the rest of the evaps on that suction line, how can I get an accurate superheat? That part confuses me still. Do I need to run each one individually and with the...
  2. Replies
    30
    Views
    1,421

    Well, I finally got time to get back over there...

    Well, I finally got time to get back over there and finish the job. I strapped the sensor from an A419 controller to the suction line about two inches from where it exits the box, immediately before...
  3. Replies
    30
    Views
    1,421

    Just noticed this post. The bypass and injection...

    Just noticed this post. The bypass and injection solenoids are energized with the compressor contactor. The bypass valve is controlled by suction pressure and the desuperheater is controlled by...
  4. Replies
    30
    Views
    1,421

    Correct. They are Trenton units.

    Correct. They are Trenton units.
  5. Replies
    30
    Views
    1,421

    Here's a few more of the progress of the job.

    Here's a few more of the progress of the job.
  6. Replies
    30
    Views
    1,421

    These aren't the best pics, just what I had on my...

    These aren't the best pics, just what I had on my phone. The hot gas ties into the suction in the bottom left of the picture then the liquid is injected just before the accumulator. This condenser is...
  7. Replies
    30
    Views
    1,421

    I will. It might be a couple weeks. I've got...

    I will. It might be a couple weeks. I've got another job coming up that I need to start on Monday. Thanks to all who replied.
  8. Replies
    30
    Views
    1,421

    I'm using semi hermetic compressors with...

    I'm using semi hermetic compressors with discharge bypass for capacity control and liquid injection as a desuperheater. On the compressors that I have running, I have around 35 degrees superheat at...
  9. Replies
    30
    Views
    1,421

    Something else I didn't mention is that all the...

    Something else I didn't mention is that all the other evaps are being controlled by electronic controllers, either A419 or existing factory controls that open a solenoid. The compressors are ran off...
  10. Replies
    30
    Views
    1,421

    The suction line is a 3/8 line that doesn't tie...

    The suction line is a 3/8 line that doesn't tie into the 5/8 common header until about 30 feet from the evaporator. If I strapped a sensor to the line immediately after the coil do you think I would...
  11. Replies
    30
    Views
    1,421

    Only 2 out of 16 had Cap tubes, and yes, I did...

    Only 2 out of 16 had Cap tubes, and yes, I did replace them with txv's. There was originally a variety of refrigerants and I have switched them all to 404a with txv's and new condensers. This...
  12. Replies
    30
    Views
    1,421

    Excuse my ignorance, but what is an automatic...

    Excuse my ignorance, but what is an automatic expansion valve?
  13. Replies
    30
    Views
    1,421

    Yes, sorry I should have been more clear on that....

    Yes, sorry I should have been more clear on that. I do plan on using a liquid line solenoid, I'm just not sure how to go about controlling the solenoid. I can't see a way to properly sense box temp....
  14. Replies
    30
    Views
    1,421

    How to control temp on medium temp box?

    I'll start by saying I have a lot of hvac experience, but haven't done much refrigeration. I'm in the process of retrofitting a hotel kitchen from self contained condensers to remote condensers. I...
  15. Replies
    34
    Views
    1,654

    So you want to jump into this field without...

    So you want to jump into this field without schooling or training and have somebody walk you through your service calls for free, as a buddy?
  16. Replies
    34
    Views
    2,309

    Agreed. Experience has taught me to always get...

    Agreed. Experience has taught me to always get replacement motors directly from Liebert. Aftermarket motors, even with ball bearings, just don't cut it.
  17. Replies
    11
    Views
    646

    I've seen the same thing on a Trane. New 410A...

    I've seen the same thing on a Trane. New 410A install by our company that was only slightly overcharged and rapidly cycling on high pressure switch. Keep is informed.
  18. Here in Utah, there really isn't a separation of...

    Here in Utah, there really isn't a separation of church and state. The Mormons quite literally run the place. The vast majority of residents, especially those not in Salt Lake City itself, are...
  19. Look closer at the pic. L1 and T1 are twisted...

    Look closer at the pic. L1 and T1 are twisted together, bypassing the disconnect. That's what is so dangerous.
  20. A punch in the head and an explanation of why you...

    A punch in the head and an explanation of why you deserved it is far less painful than hearing on the news about somebody found dead on a roof due to your laziness. I believe the guy needs to know...
  21. I used to have this exact problem. Then, due to...

    I used to have this exact problem. Then, due to some health issues (balancing problems), I had to get out of this field for a while. The only decent paying job that was readily available to me at the...
  22. HAHA! I agree 100%! I don't know how a company...

    HAHA! I agree 100%! I don't know how a company can justify paying a service tech commission on parts. Action does. I've heard some crazy **** about Whipple and Neerings as well. Mostly about how...
  23. Yeah, I did that Park City round trip yesterday...

    Yeah, I did that Park City round trip yesterday for a Rocky Mountain Power office. It does kinda suck. We haven't really been too slammed this year. We've had a few crazy days, but not real...
  24. Wow. You're lucky to be alive. I usually just...

    Wow. You're lucky to be alive. I usually just check two legs as well to make sure the disconnect disengaged. I'll be checking all three from now on though. And it's funny you should mention...
  25. Replies
    33
    Views
    1,483

    We did the hvac installation on a large Muslim...

    We did the hvac installation on a large Muslim church before, during, and after 9/11. The job site drama throughout that job would high jack this thread, but the point is their weird bathrooms. They...