Type: Posts; User: A&BHeatandcool

Search: Search took 0.00 seconds.

  1. Replies
    28
    Views
    5,804

    Nasty

    Yea after working on a few and seeing pictures on the net I have stopped getting ice in my drink. The other day Hardees forgot to not add ice and I could taste that junk in my drink. Something I...
  2. at least they did a good job putting that in lol

    at least they did a good job putting that in lol
  3. Replies
    17
    Views
    4,082

    What about the rev. valve. i am not changing that...

    What about the rev. valve. i am not changing that out mam u need a new unit
  4. Replies
    13
    Views
    1,257

    the one i was looking at wasent a 1995, it was a...

    the one i was looking at wasent a 1995, it was a 2005 chevy express with 4.8L V8, with 125K miles, full bin package, and the best part i could have got an extended warrnty from gm on it. i wouldnt...
  5. Replies
    44
    Views
    13,876

    the no substature for a bottle of big blue soap,...

    the no substature for a bottle of big blue soap, torch and 15% silver to fix a leak.
  6. Replies
    36
    Views
    3,614

    the new infacon tec-mate that i have seems to be...

    the new infacon tec-mate that i have seems to be holding up good, has been more accurate than the old fieldpiece i had before.
  7. Replies
    59
    Views
    10,908

    i have the fieldpiece, i have had realy good luck...

    i have the fieldpiece, i have had realy good luck with it and the measurements match up with the fieldpiece check me theat i have, so i guess its pretty accurate.
  8. Replies
    31
    Views
    2,243

    i have a set of testo 550's i havent had anny...

    i have a set of testo 550's i havent had anny trouble out of them.
  9. Replies
    13
    Views
    1,257

    the van that i told you guys about, i went to...

    the van that i told you guys about, i went to look at it and by the time i got to the commershall sales lot it had done been sold. :gah: what i planded on doing is buy the van with $1,500 down, put...
  10. Replies
    59
    Views
    5,408

    go ridgid just register the tools like there for...

    go ridgid just register the tools like there for home use to get the lifetime replacement warnty :whistle:
  11. Replies
    13
    Views
    1,257

    need advice on a service van !!!

    back last year when i started my company, i bought a 1995 E-250 cargo van to start out with. i paid only $800 for it and it included all the bins, ladder rack and the 195K of road miles to go with...
  12. Replies
    11
    Views
    2,230

    I might be an idot but with a dirty con. why will...

    I might be an idot but with a dirty con. why will you need to replace the cap tube??
  13. Replies
    9
    Views
    1,336

    at least you added ports. i see nothing wrong...

    at least you added ports. i see nothing wrong with that
  14. Replies
    9
    Views
    1,336

    the only way that they could add freon was...

    the only way that they could add freon was through perm. suction. pulling a vac on the unit if they did it at all could not have been acheeved correctely.
  15. Replies
    9
    Views
    1,336

    yep i forgot you are right they did have the...

    yep i forgot you are right they did have the quick connect. bugs the he!! out of me
  16. Replies
    9
    Views
    1,336

    valve bandit

    This is the third unit i have serviced that is missing the service valves and ports. This is an old intertherm not the best unit in the world but they can take abuse pretty good. :gah: i have found...
  17. Replies
    12
    Views
    2,499

    I bet it wont last long!! The compressor must...

    I bet it wont last long!!

    The compressor must love that.:gah:
  18. Replies
    18
    Views
    3,826

    people like that keep us in our jobs lol. its a...

    people like that keep us in our jobs lol. its a good thing that this did not kill the HO.
  19. Replies
    18
    Views
    3,826

    i see this all the time. installers must think...

    i see this all the time. installers must think all furnaces are OK to be vented with PVC. oh yea i love the sheet metal screw holding the pipe to the furn.
  20. Replies
    30
    Views
    11,815

    HA HA

    Lets explain the ref cycle. the freon leaves the compressor as a gas and goes through the condenser where it is condensed and leaves as a liquid. Waite a min. Thats one of the new metering devices,...
  21. Replies
    11
    Views
    1,805

    Going back to do a pump down to check comp valve...

    Going back to do a pump down to check comp valve and amp draw. I will post back next week
  22. Replies
    11
    Views
    1,805

    Txv test with sen bulb removed and heated no...

    Txv test with sen bulb removed and heated no change, when cooled in ice water no change. added ref. super heat went down still no subcooling added about a pound
  23. Replies
    11
    Views
    1,805

    i have not went back getting some pricing...

    i have not went back getting some pricing together to let HO know what it will cost to move units / fix txv OR Replace with a Dry R22 unit My line set is in brick 3 floors up. HO does not want line...
  24. I herd at the parts counter that trane was to...

    I herd at the parts counter that trane was to fire the ceo and have recently mfg several thousand commercial units with the suct accu in backward causing LOTS of problems and that they may go under....
  25. Replies
    11
    Views
    1,805

    superheat 12.6, subcooling 1.1 head 213 suct 89.0...

    superheat 12.6, subcooling 1.1 head 213 suct 89.0 this unit has a VS blower.
  26. Replies
    11
    Views
    1,805

    units on brick wall ect

    HO called and said it was a little stuffy up stairs. When I got there temp was 73 and hum 65+. Went outside and found several problems. First the units are too close to the house. Second the units...
  27. Replies
    10
    Views
    2,046

    Just me

    :.02: I know everyone has their own way of doing things but, i never like to put collers that close to the end. you need back pressure i like to stay 2-3 feet off the end again just my :.02: other...
  28. Replies
    9
    Views
    3,314

    HO said it smells like its hot

    I wonder why nobody every thinks a unit needs to breathe. Ho called me to check it out as soon as I went out the back door I could hear the compressor straining and the fan suffocation for air flow....
  29. Ha its a little warm here

    Looks like one of the units has a sharp 90 in the suction instead of a refrigeration 90, its always nice to work on these i bet!!:bump:
  30. Replies
    3
    Views
    1,877

    owner

    Thats the way it was designed it to work right?? LOL:.02:
  31. Replies
    6
    Views
    1,197

    sorry i should have told you this is a heat pump....

    sorry i should have told you this is a heat pump. all that is there is a perm. suction and suction line, and the suction line service valve is put in backwords.
  32. Replies
    6
    Views
    1,197

    Where is the D@M liquid line port

    This is a new customer for regular PM she called me to do a check up and to keep the unit serviced. I found this, what a mess!! she said she has not had anybody come to look at the unit i several...
  33. Replies
    0
    Views
    884

    how close can i set this?

    :gah:Got a call from a coffee shop and gym in one place. Gym side cold and coffee hot. When I got there I found this. The two cond. units on the left go to one air handler inside also? 3 1/2 ton...