  1. Replies
    17
    Views
    554

    As far as a vacuum pump, that is a given, was...

    As far as a vacuum pump, that is a given, was talking about will it read microns and it appears it only reads "HG, so its time to buy a new micron gauge, what micro gauge is everyone using?
  2. Replies
    17
    Views
    554

    AK900 to pull a vacuum?

    Can i use my New AK900 to pull a vacuum?
  3. Replies
    1
    Views
    489

    Help with Propane Forced air Heaters

    Need help deciding on the correct propane forced air heater for my little shop (2560sqft) 14 foot ceilings + rafters of 6' to peak, no ceiling yet) until I frame it out. What brand do people use for...
  4. Replies
    5
    Views
    1,111

    Manitowoc ice maker QY0455W help

    I have a customer that I cant get the ice unit just right. I have it starting to making ice but the ice quality is poor.

    Here is the back ground.
    Customer went to clean the unit himself and ran...
  5. So here is another kicker. The engineer stated...

    So here is another kicker. The engineer stated that their driers shall be put into systems that are contaiminated with acid without puting an acidaway product. He made mention that their suction...
  6. They are considering the common between the...

    They are considering the common between the compressor and the reversing valve. I actually talked to one of the design enginners on the drier.
  7. I jsut spoke to spoland and they said its an old...

    I jsut spoke to spoland and they said its an old qwives tail to cut them out of the common suction on a heat pump if it was put there. However if its in the reversing side it must be cut out. Looks...
  8. Fairfax

    Fairfax
  9. Near the beltway in northern virginia

    Near the beltway in northern virginia
  10. Thats not listed any where I can find. I have...

    Thats not listed any where I can find. I have seen them left in for the life of some units. Actually most of the ones on this ob were installed with them from the original install, but those are...
  11. Trane 5 ton unit with suction filter question

    I have a 5 ton heat pump that the compressor was burnt up due to acid. I cleaned the system and installed a suction drier and locked the system in cooling by supplying 24v to the reversing valve all...
  12. Replies
    23
    Views
    2,582

    How come my post got deleted?

    How come my post got deleted?
  13. Replies
    23
    Views
    2,582

    High Amperage Hardly. It has an Amp draw on...

    High Amperage Hardly. It has an Amp draw on compressor: 8.5amps and the name plate was 9.0 amps. Your saying thats high?
  14. Replies
    23
    Views
    2,582

    If the cap tube was plugged would I get any...

    If the cap tube was plugged would I get any cooling? I am geting some cooling in the unit as it was able to pull down to 41 -42F for a little while then it would go up then it would come back down......
  15. Replies
    23
    Views
    2,582

    Factory recommends never to open system and use...

    Factory recommends never to open system and use the temp drops across the evap and condenser. I wasn't satisfied with what I saw so I saw some one else installed a clamp on add a port and was...
  16. Replies
    23
    Views
    2,582

    Ahhh yes the most important part its 134a. And no...

    Ahhh yes the most important part its 134a. And no port on high side. I am an authorized service agent for true so yes they will get a phone call in the morning.
  17. Replies
    23
    Views
    2,582

    Help with true T-49 unit

    True T-49 unit is not cooling

    I have checked the unit and have a problem beleiving after one year that the compressor is bad.

    Here is the data i collected today:
    Box Temp: 43-54 (Fluctuates...
  18. Replies
    134
    Views
    26,529

    I want a copy.... PLEASE PLEASE PLEASE...

    I want a copy.... PLEASE PLEASE PLEASE...
  19. Replies
    15
    Views
    1,482

    Got two ST-4's work good unless you leave them...

    Got two ST-4's work good unless you leave them powered on...... and go to use them again and the battery is dead!!! Thats why i carry at least 4 9 volt batteries in the truck at all times.
  20. I got mine when they came out for $149.00 minus...

    I got mine when they came out for $149.00 minus the bag/ case
  21. Replies
    15
    Views
    1,884

    WHat is your suggestion if there is no floor...

    WHat is your suggestion if there is no floor drain? THere is a slop sink however.
  22. Replies
    15
    Views
    1,884

    Is it acceptable to hook the drain to the...

    Is it acceptable to hook the drain to the condensate going outside? I have seen some of them hooked up this way and they changed the trap out for the one that has the microswitch in it to shut down...
  23. Replies
    15
    Views
    34,309

    I have a customer that had their basement...

    I have a customer that had their basement finished. The HVAC guy put the supply ducts in but they forgot to cut in the return for the basement. Customer states when they have a party in the basement...
  24. Replies
    14
    Views
    804

    2007

    2007
  25. Replies
    14
    Views
    804

    Well I paid my money for the guy to say replace...

    Well I paid my money for the guy to say replace the water valve first. then the Control board then the touch panel. By that time the customer could but two dishwashers...... Damn wish i could find an...