Search:

Type: Posts; User: lifeline

Search: Search took 0.00 seconds.

  1. Sticky: Here's my experience in the trades. 25 years ago...

    Here's my experience in the trades. 25 years ago I started in the electrical trade as a apprentice. 4 years later I became a journeyman red seal electrician. For the next 7 years I continued in the...
  2. Replies
    53
    Views
    2,739

    Sorry he didn't say anything about keg beer. I...

    Sorry he didn't say anything about keg beer. I was thinking bottled. So what should the zam temp be? For the beer on tap. Still think he has a refrig problem. Regardless of temp.
  3. Thread: Run Capacitor

    by lifeline
    Replies
    6
    Views
    512

    This is the Ask Our Pro's forum, and only Pro...

    This is the Ask Our Pro's forum, and only Pro members that have been vetted by the AOPC may post advise, commentary, or ask questions of the OP here.

    You can find the rules for posting and...
  4. Replies
    53
    Views
    2,739

    For beer we try to keep our box temp as close to...

    For beer we try to keep our box temp as close to 32deg f as possible. To do this your refrigeration system has to be sized right and running at its best. And as crazifuzzy said it will need a time...
  5. Replies
    53
    Views
    2,739

    If the coil isn't freezing completely and only in...

    If the coil isn't freezing completely and only in a section if the coil you have a refrigeration problem not a control problem. Check your superheat. It will tell you a lot. Placing the temp control...
  6. Replies
    21
    Views
    1,405

    Just a follow up on my findings yesterday. At...

    Just a follow up on my findings yesterday. At compressor 26deg sh
    Oil pressure loaded and un loaded 44psi. Hasn't tripped for over a week. Oil is still quite bubbly... The crankcase pressure is the...
  7. Replies
    21
    Views
    1,405

    Pumps down to 4psi. No leakage: probably be back...

    Pumps down to 4psi. No leakage: probably be back tomorrow for follow up.
  8. Replies
    21
    Views
    1,405

    I can appreciate all said here. I have to get...

    I can appreciate all said here. I have to get back and check super heat values. As an added info. I checked records today and the problem started after I got the unloaders back online.
  9. Replies
    21
    Views
    1,405

    Your right it is a big cooler. 2 40 horse units...

    Your right it is a big cooler. 2 40 horse units for the one box. 2 evaps each, hog halves hung after killed for drip. The decision to use the unloaders is not mine. I don't think we should unload at...
  10. Replies
    21
    Views
    1,405

    Yes there is a pump down not sure about fans. I...

    Yes there is a pump down not sure about fans. I think not but will check next time I'm there.
  11. Replies
    21
    Views
    1,405

    New sensor. Not short cycling. Of course it...

    New sensor. Not short cycling. Of course it doesn't trip when we are there.
  12. Replies
    21
    Views
    1,405

    That's my net. Oil pressure 80 minus suction...

    That's my net. Oil pressure 80 minus suction pressure 40
  13. Replies
    21
    Views
    1,405

    A bit more info that I remembered. The problem...

    A bit more info that I remembered. The problem started after I brought the unloaders back online. I also added refrigerant yesterday to clear the sight glass ( found a leak at the compressor). Next...
  14. Replies
    21
    Views
    1,405

    40 ton oil failures

    I have a 40 ton copeland semi with nuisance oil failure tripping. 40 psi oil pressure, r22, walkin cooler with a space temp in the range of 30 to 40 deg f. Oil sight glass may be a little high about...
  15. Replies
    27
    Views
    3,989

    If your only problem is a tripping breaker you...

    If your only problem is a tripping breaker you need to increase the circuit size to the unit. #12 wire wire is rated for 20 amps but not allowed to be loaded above approx 16A. Have a #10 circuit run...
  16. Replies
    4
    Views
    786

    the bowl is plastic and the plastic fittings that...

    the bowl is plastic and the plastic fittings that the hoses attach to are breaking off. 2 out of six are broken. The ice is mixed in with food product and I can't risk more breaking off and possibly...
  17. Replies
    4
    Views
    786

    howe ice flaker

    could someone provide with steps to replace the water distribution bowl in a 2000rl howe flaker
Results 1 to 17 of 17