  1. Replies
    0
    Views
    223

    2 X 2 t-bar diffuser with damper

    I'll looking for some help to find a company that makes a 2 x 2 t-bar diffuser w/ a damper already installed in the diffuser. I know they make retro kits. But since this a new install, I would rather...
  2. Replies
    5
    Views
    690

    Just a quick update. The HPS was no closed all...

    Just a quick update. The HPS was no closed all the way, even though it passed a continuity test. Thanks for the help.
  3. Replies
    5
    Views
    690

    York RTU no cooling

    I have a York RTU D3NZ036 unit that the customer complained of no cooling. The unit has 24v to the Y terminal on the control board, but the 24v contactor doesn't engage, and there is not 24v at the...
  4. cfe, anymore issues with this unit? I have the...

    cfe, anymore issues with this unit? I have the exact same codes on a 4 ton ZJ series York unit. I changed the filters and checked voltages. Ran the unit for two hours no issues. If you have any other...
  5. Replies
    2
    Views
    552

    Thanks for the help.

    Thanks for the help.
  6. Replies
    2
    Views
    552

    York ZJ series wiring diagram

    I'm looking for a wiring diagram for a York ZJ series RTU. The model number is ZJ048N10A1AAA1. The one on the inside of the panel is too faded to read. Thanks for any and all help.
  7. Replies
    19
    Views
    2,533

    Not trying to be smart. But a r-22 unit shouldn't...

    Not trying to be smart. But a r-22 unit shouldn't have anything else used in it. If a system needs r-22 on a regular basis, its probably time to replace it with a R-410a system.
  8. Replies
    0
    Views
    297

    Tork draft inducer motor

    Does anyone have a link to check the compatibility of York draft inducer motors. I have a OEM motor Fasco part number 71211958, and I am trying to check if a York S1-02424115018 is interchangeable...
  9. Replies
    21
    Views
    2,421

    Heard of it, but never ran into it. I thought it...

    Heard of it, but never ran into it. I thought it was more prevalent in the humid south, and more commonly associated with high eff. equipment. The unit is about 20 years old, so replacing just the...
  10. Replies
    21
    Views
    2,421

    The mouse makes sense. I'll run a camera through...

    The mouse makes sense. I'll run a camera through the ductwork to check it out.
  11. Replies
    21
    Views
    2,421

    One of my first thoughts also. But the drain line...

    One of my first thoughts also. But the drain line exits the building through the wall and terminates directly outside., so there is no connection to any type of sewer line.
  12. Replies
    21
    Views
    2,421

    No, just standard ductboard. The heat strip was...

    No, just standard ductboard. The heat strip was visually inspected and looks and operates normally. The customer says "sewer" smell, I have been unable to smell it on two previous visits, however, an...
  13. Replies
    21
    Views
    2,421

    "sewer" smell from the ductwork

    I have a customer complaining of a "sewer" smell coming from the ductwork. The smell only seems to be noticeable when the aux heat strip is on. The air handler is an older Trane unit with 10kw...
  14. Replies
    8
    Views
    938

    Failed compressors

    Had two different units with failed compressors in the past two weeks. One was Carries 48SS series RTU and the other was a Trane HP split system. Based upon the tests I ran the 48SS seemed to be a...
  15. Replies
    5
    Views
    800

    Thanks

    Thanks
  16. Replies
    5
    Views
    800

    Carrier 48SS cap size

    Does anyone have information on cap sizes for a Carrier 48SS030080301 RTU. The old one is too faded to read. Thanks.
  17. The local supply house, APR Supply, told me last...

    The local supply house, APR Supply, told me last week that dry R-22 condensers are available.
  18. Freeing the compressor by hitting with a hammer...

    Freeing the compressor by hitting with a hammer is a temporary fit. Almost always its going to stop again, plan on replacing it on your schedule, not on the the compressor's. (probably a weekend)...
  19. Replies
    34
    Views
    3,381

    Evacuated to 28 in of vacuum, and 275 microns...

    Evacuated to 28 in of vacuum, and 275 microns ,and held 28 in for two hours so no leaks, of course also changed the drier.
  20. Replies
    34
    Views
    3,381

    Compressor operating in a vacuum

    About a month ago I got a call from a tenant with a Trane unit TWL736A100AO stating that the unit wasn't cooling. I usually do my own service work but was out of town. I called the service company I...
  21. Thread: Inspectors

    by juststartin
    Replies
    5
    Views
    480

    Inspectors

    Just remodeled a 1200 square foot commercial space for a tenant and installed a Lennox split system heat pump. So the fire inspector is there to give the Occupancy Permit, he looks at the outside...
  22. Replies
    29
    Views
    1,525

    The Volt may get 230 MPG, but the design is such...

    The Volt may get 230 MPG, but the design is such that the bulk of your use will be done by charging the batteries with AC current from your home. Since the electricity in the NE is mostly generated...
  23. Replies
    4
    Views
    488

    Based upon the York nomenclature I could find...

    Based upon the York nomenclature I could find that model has 76,000 BTUs of cooling. I don't know of the date of manufacture, although since its a 4 model its a 4th generation of the series, so it...
  24. Replies
    4
    Views
    679

    Thanks.

    Thanks.
  25. Replies
    4
    Views
    679

    Single phase 208/230V

    Single phase 208/230V