  1. Thread: Heat Strips

    by vet
    Replies
    13
    Views
    612

    Ohm meter from housing to heat strips shows no...

    Ohm meter from housing to heat strips shows no continuity, and only one side of the 230 v line is hooked up and will feed 115v through to one side but should not heat up the strip.
  2. Thread: Heat Strips

    by vet
    Replies
    13
    Views
    612

    Heat strips

    Ohm meter from housing to heat strips shows no continuity, and only one side of the 230 v line is hooked up and will feed 115v through to one side but should not heat up the strip.
  3. Thread: Heat Strips

    by vet
    Replies
    13
    Views
    612

    Heat Strips

    Have a 230 volt set of strips that heat up with only one hot leg hooked up, never had this happen before in an older unit. Maybe some one here has had this problem the other set of strips work fine,...
  4. Been running for 7 yrs now, had to remove suction...

    Been running for 7 yrs now, had to remove suction driers and noticed the high head pressure, had two driers in a row. After removal 68 wet bulb,90 O.D.T, calls for 16 degree S. H. 73 psig and a...
  5. miss matched exsisting piston type system.

    To get correct superheat, Head psig will run around 325 at 90 Outside Air temp. Piston type coil exsisting system as stated 2 1/2 ton cond on a 2 ton evap.
  6. Miss match sizing effects on pressure with 1/4 in liquid line.

    Have a 2 1/2 ton condenser on a 2 ton evap coil and only a 1/4 in liquid line and a 5/8 suction line running 30 ft. vertically. What happens to the psig on hi and low side?
  7. Replies
    10
    Views
    1,288

    Arkla Gas a/c Systems

    I worked on Arkla Servels for 10 yrs. They are not very efficient and maint on them can be costly, cleaning tanks twice a year,and cleaning of the generator. Belt replacements, timers,etc. Same with...
  8. Replies
    12
    Views
    1,617

    Small line set's for R410-A

    What would be the effect on PSIG in a 410 unit with liquid lines of 3/16, 1/4 & 5/16? Also Suction lines range from 5/8 to 3/4. Units are only 2 Tons & 1.5 Tons. 50 to 80 Ft. run's? Owner's will...
  9. Thread: Liq Driers

    by vet
    Replies
    6
    Views
    506

    Thanks men I wasn't really sure since I never...

    Thanks men I wasn't really sure since I never knew any one who had ever done it before and left it, I have been in a rush and did one once but I also turned it back around. So thanks for the info, I...
  10. Thread: Liq Driers

    by vet
    Replies
    6
    Views
    506

    Liq Driers

    In all my 30 years I have never seen a drier installed backwards, so I have no idea what effect it would have on a r-22 a/c system. Has any one checked a unit out under these conditions? On the liq...
  11. Replies
    3
    Views
    467

    Remove the Lets not give out too much DIY advise....

    Remove the Lets not give out too much DIY advise. While the OP says he is in the trade, this being the open forum, the info you post is open for all to see.
  12. Replies
    15
    Views
    4,210

    Thanks for the info on this, I did plan on...

    Thanks for the info on this, I did plan on replacing all evap coils just was not sure about the line set's.
  13. Replies
    15
    Views
    4,210

    I am a 30 yr tech in the A/C field but due to...

    I am a 30 yr tech in the A/C field but due to mobility problems ive been out of the loop for about 5 yrs now. Now i take care of a 296 apartment complex with electric carrier 1.5 ton to 2 ton...
  14. Replies
    53
    Views
    6,054

    I'm sure you are right about this, but now they...

    I'm sure you are right about this, but now they wont have to search around for unit's just walk into any supply house and pick out your own non filled unit. We all have enough problems as it is, i...
  15. Replies
    53
    Views
    6,054

    Is there not a law that without epa certificate...

    Is there not a law that without epa certificate you are not allowed to buy or transport any container with refrigerant in it? That's why mine is on file at all my distributors, and we wont hire any...
  16. Replies
    53
    Views
    6,054

    Will this substitute R-22 be another hit and miss...

    Will this substitute R-22 be another hit and miss product like those can's of leak seal?
    I have checked on the new non filled R-22 systems and yet the cost of those units are still the same, they...
  17. Replies
    63
    Views
    4,148

    Never had much luck with any universal motor's or...

    Never had much luck with any universal motor's or multy horse power motor's either, but that being said most all the other post were right. Get a good tech to install the right motor and from there...
  18. Replies
    17
    Views
    2,173

    Run the low voltage inside 1/2 in. Pvc pipe, its...

    Run the low voltage inside 1/2 in. Pvc pipe, its cheap and a lot easier, use schedule 40 the thicker type. All you will need is some elbows, male to slip fitting etc.
  19. Houston Texas

    I worked in Houston for 30 yrs in A/C service, try Premier heating and air. They will do a load calculation etc and if anything goes wrong they will fix it right away. I now live in Missouri so I no...
  20. Replies
    147
    Views
    9,525

    home owner

    I'm sorry but as I was always told, your not paying for what I do as much as for what I know period. Im sure your boss pays you for the same reason. And for future notice since gas is going out of...
  21. Replies
    194
    Views
    9,440

    Which Unit

    I have not read all the threads here but are these company's talking R-22 or R410-A ? That would really put a damper on the line set Problem. In Houston Tx. Carrier would not warranty a unit of...
  22. Zones

    We installed 100 's of these in two story homes and even three, on one unit.
    Your Installer will need to be good at cfm,heat load, etc, your bypass damper will have to be sized to be able to carry...
  23. Thread: Goodman failing

    by vet
    Replies
    31
    Views
    2,089

    Goodman

    Have the Tech check the vent tube and the vent chamber for any rust blockage or bits of broken rust particles also have him check the flue vent for any small obstruction. Those issues do cause...
  24. Replies
    67
    Views
    6,986

    Hot & cold

    I lived in Houston from 1980 to 2005 and I also worked as an A/C Tech for those years, heat pumps are not usually used since for the most part you may only get a month of cold weather and not in a...
  25. Replies
    21
    Views
    2,024

    Compressor

    Its hard to say what might be the problem since you have had several Techs out already. Did they check the capacitor under a load? A unit could still come on in certain conditions like early mornings...