Can work out bad for the customer too. I heard of...
Can work out bad for the customer too. I heard of one company like that would just not show up if they were not getting paid.
-
Yesterday, 01:23 PM
- Replies
- 5
- Views
- 122
It's just basic stuff. If you can read a wiring...
It's just basic stuff. If you can read a wiring diagram and know how the refrigerant circuit works you will pass
-
05-20-2013, 08:59 PM
Thread: truck stock?
by martyinlincoln- Replies
- 15
- Views
- 339
Txv's,capacitors,contactors,...
Txv's,capacitors,contactors, motors,refrigerant,filter driers and a good leak detector will take care of 99% of your calls.
-
05-19-2013, 04:49 PM
Thread: Smoker Newbie
by martyinlincoln- Replies
- 8
- Views
- 588
http://www.tractorsupply.com//ProductDisplay?urlRe...
http://www.tractorsupply.com//ProductDisplay?urlRequestType=Base&catalogId=10051&categoryId=&productId=113604&errorViewName=ProductDisplayErrorView&urlLangId=&langId=-1&top_category=&parent_category_r...
-
05-19-2013, 04:28 PM
Thread: Feeling taken advantage of...
by martyinlincoln- Replies
- 13
- Views
- 607
Can't say if it's the case on yours or not but I...
Can't say if it's the case on yours or not but I have seen condensing coils cost more than a new AC. It's worth a try to repair the leak. Worst cases the super thin copper melts before the brazing...
-
05-17-2013, 08:51 PM
Thread: Lennox txv
by martyinlincoln- Replies
- 15
- Views
- 548
No recalls on coils that I know of,please post...
No recalls on coils that I know of,please post model numbers. A Y0515 or 56J20 txv are not that expensive either.
-
05-17-2013, 01:24 PM
Thread: charge compensator advice
by martyinlincoln- Replies
- 3
- Views
- 200
Call Lennox and ask the applications guys.
Call Lennox and ask the applications guys.
-
05-14-2013, 07:23 PM
Thread: Acid tests
by martyinlincoln- Replies
- 4
- Views
- 163
http://www.johnstonesupply.com/storefront/supplies...
http://www.johnstonesupply.com/storefront/supplies/installation-maintenance-supplies/cleaners-chemicals/acid-control//prodB13-043.html
-
05-13-2013, 08:00 PM
- Replies
- 7
- Views
- 312
Buy one of the fieldpiece charging jackets. Works...
Buy one of the fieldpiece charging jackets. Works perfect for those conditions.
-
05-13-2013, 07:50 PM
- Replies
- 43
- Views
- 1,149
That was close to my experience with sealant as...
That was close to my experience with sealant as well. Only did 10 old systems where the customer was willing to be a guinea pig. Out of the 10 only two are still working. That was before they had...
-
05-13-2013, 07:31 PM
Thread: Goodman compressor
by martyinlincoln- Replies
- 16
- Views
- 355
Good. Words of advise... don't work on your own...
Good. Words of advise... don't work on your own equipment since you rent. Very easy for the management to blame you and guess who gets to pay for it.
-
05-13-2013, 12:41 PM
- Replies
- 3
- Views
- 214
Wag...corrosion caused the fins to seperate from...
Wag...corrosion caused the fins to seperate from the copper.
-
05-13-2013, 07:31 AM
- Replies
- 4
- Views
- 149
Dye is just oil and coloring,it has no smell....
Dye is just oil and coloring,it has no smell. Sealants are colorless and have a smell like acetone and epoxy mixed together. Excess moisture will tint the oil with a sligh smell. Green slime forms...
-
05-11-2013, 10:42 AM
Thread: service tech/sales
by martyinlincoln- Replies
- 13
- Views
- 472
Service manager and owner do the bids at our...
Service manager and owner do the bids at our shop. I give one of them a call and they come out ASAP,usually within a couple hours. They will bring space heaters or window AC's if needed. I'll spend...
-
05-10-2013, 07:20 PM
Thread: Combustion Analyzers
by martyinlincoln- Replies
- 26
- Views
- 557
No way to repair the thermocouple?
No way to repair the thermocouple?
-
05-09-2013, 06:49 PM
- Replies
- 8
- Views
- 300
Go for the 410A. While R22 will be around for...
Go for the 410A. While R22 will be around for many years it is 5 times more expensive than it was just a few years ago due to being phased out.
-
05-09-2013, 06:40 PM
- Replies
- 18
- Views
- 523
Take the refund.
Take the refund.
-
05-09-2013, 06:26 PM
- Replies
- 19
- Views
- 691
Same here. It's not like the coil had mineral oil...
Same here. It's not like the coil had mineral oil pumping through it for 10 years.
-
05-08-2013, 06:24 PM
- Replies
- 18
- Views
- 523
You stated the furnace is level. Read the...
You stated the furnace is level. Read the installation instructions and see if it's supposed to be level. That water splash noise is not normal.
-
05-04-2013, 09:18 AM
Thread: Need help
by martyinlincoln- Replies
- 8
- Views
- 294
Probably the compressor shorted to ground. A...
Probably the compressor shorted to ground. A contactor with one leg shunted allows currant to flow through the fan windings and back to the grounded compressor, making the fan operate with 120V and...
-
04-30-2013, 07:11 PM
Thread: Can A Heat Pump Run Too Much?
by martyinlincoln- Replies
- 6
- Views
- 433
That thermostat will give you a goofy error code...
That thermostat will give you a goofy error code if the heat pump runs more than so many hours at a time. I don't remember the exact number of hours but it's somewhere around 15. Just posting a...
-
04-28-2013, 10:25 PM
Thread: Heat Pump making hissing noise
by martyinlincoln- Replies
- 6
- Views
- 212
Discharge drier?
Discharge drier?
-
04-27-2013, 08:19 AM
- Replies
- 5
- Views
- 370
Classes I went to said a sight glass will not...
Classes I went to said a sight glass will not clear. Flashing in the sight is what you're seeing. The isobutane is in the mix to aid in oil return so shouldn't need to add POE. Last I heard up to 5%...
-
04-24-2013, 06:58 AM
- Replies
- 13
- Views
- 461
Not uncommon to see a little growth and it...
Not uncommon to see a little growth and it probably is one of the hundreds of varieties of mold that's around us everywhere. Have him clean the thing and change the filter a little more often. No...
-
04-17-2013, 06:56 PM
- Replies
- 10
- Views
- 323
Assuming the furnace is right behind that wall,...
Assuming the furnace is right behind that wall, he would be correct. A 3 1/2" deep stud cavity can not carry enough air for a whole system. Drawing from a platform straight out that grill it can get...