01-31-2013, 09:30 PM
Thread: Work boots!
by Lifer- Replies
- 92
- Views
- 8,053
I'm wearing a new boot to me. Georgia Boot....
I'm wearing a new boot to me. Georgia Boot. http://www.georgiaboot.com/ I have to say I am pleased with the fit. They had a pdf. file that you print and measure your size. I have been wearing mine...
-
01-26-2013, 08:52 AM
- Replies
- 49
- Views
- 2,540
I have been using an H-10 for the past 20 yrs....
I have been using an H-10 for the past 20 yrs. and have found that it is always done a great job at making money with leaks. I have seen other techs come and go, with other units and nothing beats...
-
01-26-2013, 08:30 AM
Thread: Heat Controller
by Lifer- Replies
- 7
- Views
- 468
That's a Nordyne for sure. The fan is the same as...
That's a Nordyne for sure. The fan is the same as the Nordyne, and with the plastic bottom it has to be Nordyne.
-
12-03-2010, 02:46 PM
Thread: H-10 guru's
by Lifer- Replies
- 25
- Views
- 1,444
Bob the Bull has it right. I got my first H-10...
Bob the Bull has it right.
I got my first H-10 "B" back some 20 yrs ago.
I love them and once you use them and get a feel for it then you will not leave it. -
01-21-2006, 06:06 PM
Thread: New to the forum, check out my work.
by Lifer- Replies
- 26
- Views
- 4,950
No aux. drain pan under unit here in NC that is...
No aux. drain pan under unit here in NC that is code violation, and code is the minimun standard. What happened to the strapping the flexibile duct at least for the return duct. Shouldn't you put...
-
01-04-2006, 08:42 PM
Thread: california economizers
by Lifer- Replies
- 20
- Views
- 2,967
I live in wilmington NC and I have been using...
I live in wilmington NC and I have been using Cal. Econo. systems. I have used Mr. Goins in the early days of the system 1000 controllers and I have had nothing but good service from both systems and...
-
01-04-2006, 07:34 PM
Thread: Water in Reclaim Tank
by Lifer- Replies
- 2
- Views
- 529
I never use reclaimed refrigerant ALWAYS virgin...
I never use reclaimed refrigerant ALWAYS virgin refrigerant.
-
12-05-2005, 12:23 AM
Thread: Flex duct doesn't have to be ugly
by Lifer- Replies
- 47
- Views
- 7,664
So if the primary drain cloggs then water fills...
So if the primary drain cloggs then water fills the emergency pan (under the air handler) and drains fine through the emergency drain line but doesn't shut off the system because it dosen't fill high...
-
11-29-2005, 11:28 PM
Thread: Amana (Not Goodman) Furnace Quality??
by Lifer- Replies
- 7
- Views
- 1,362
Here on the coast of N.C. there is little heat...
Here on the coast of N.C. there is little heat load and high cooling loads. The last gas pack I installed was around this time last year. Then I installed a GPG1230070 Johnstone supply told me that...
-
11-29-2005, 10:46 PM
Thread: Amana (Not Goodman) Furnace Quality??
by Lifer- Replies
- 7
- Views
- 1,362
Hey Robo is there a way you can relay the need...
Hey Robo is there a way you can relay the need for a low Btu gas pack in the goodman line say 50k.
-
09-21-2005, 12:05 AM
Thread: HVAC install instructions for DIY
by Lifer- Replies
- 15
- Views
- 1,196
I did as the instructions said but the unit shook...
I did as the instructions said but the unit shook and fell out the window and hit the man walking down the street. Please write back and tell me how to get the window shut before the cops come and...
-
RoBoTeq, Hey If you would not like to recomend...
RoBoTeq,
Hey If you would not like to recomend a matching unit that is ok. -
RoBoTeq, Thanks for the quick reply. ...
RoBoTeq,
Thanks for the quick reply.
Changing the outdoor unit and I was wandering if a cplj or a cplt would match up ? -
Hey can any one tell me what SEER rating is this...
Hey can any one tell me what SEER rating is this system and does the air handler have a TXV
Amana
Indoor # BHA30FA002A
Outdoor # RHD30A2A -
06-29-2005, 09:33 PM
Thread: 410A- using r22 guages
by Lifer- Replies
- 14
- Views
- 1,225
r22 systems uses mineral oil and it doesn't mix...
r22 systems uses mineral oil and it doesn't mix with P.O.E. oil that is used in 410 systems it is like water and oil.
-
06-29-2005, 09:16 PM
Thread: 410A- using r22 guages
by Lifer- Replies
- 14
- Views
- 1,225
Too late damage is already done to 410 system.
Too late damage is already done to 410 system.
-
06-29-2005, 09:13 PM
Thread: TXV Charge and performance
by Lifer- Replies
- 24
- Views
- 1,876
Did you do a load calc on the building? Sounds...
Did you do a load calc on the building? Sounds like the equipment is under sized. Is the fan settings correct?
-
05-30-2005, 05:51 PM
Thread: Variable Speed Vs. Single Speed Furnace
by Lifer- Replies
- 9
- Views
- 2,187
Variable speed is the way to go. Yes...
Variable speed is the way to go. Yes dehumidification is great but also there is no cold starts in heat mode either. Trane VS units have a 50% setting for constant blower mode which is good for air...
-
05-30-2005, 05:37 PM
Thread: Soldering vs. brazing
by Lifer- Replies
- 37
- Views
- 4,237
I work with a oxy/acet set up that way I can...
I work with a oxy/acet set up that way I can regulate the heat needed for the most part but when I go into an attic I take my mapp turbo torch.
When I run line sets I use just heat to melt copper... -
05-30-2005, 05:14 PM
Thread: Memorial Day
by Lifer- Replies
- 4
- Views
- 514
Thank God Thank a Vet.
Thank God
Thank a Vet. -
05-22-2005, 08:23 PM
Thread: Million dollar moron printing b s
by Lifer- Replies
- 26
- Views
- 1,954
I don't know about your customers but we have...
I don't know about your customers but we have only perferred customers.
When a customer calls we try to serve their need in a timely fashion. If we don't someone else will. -
05-03-2005, 11:57 PM
Thread: Leak detectors
by Lifer- Replies
- 16
- Views
- 1,579
H-10 Everyone says that theirs is equal to the...
H-10 Everyone says that theirs is equal to the H-10.
I have been using mine for 10 years.
Works great. -
05-03-2005, 11:51 PM
Thread: Running on empty (scroll, that is)
by Lifer- Replies
- 49
- Views
- 2,637
I set many a Trane units and I have had two with...
I set many a Trane units and I have had two with a noise complaint that happened to be the hot gas tube knocking on the base. GOOD CALL Mark. I say give the dealer a try at fixing the noise and if...
-
04-28-2005, 07:39 PM
Thread: to pay or not
by Lifer- Replies
- 8
- Views
- 848
Well be honest to the contractor and tell them...
Well be honest to the contractor and tell them that you have got estimates that range from blank to blank and before they install that you would like them to do a calc.
For me to do a block load... -
04-28-2005, 07:31 PM
Thread: refridgerant lines leak check
by Lifer- Replies
- 17
- Views
- 1,141
Add nitrogen to 100 psig. and test with soap...
Add nitrogen to 100 psig. and test with soap bubbles or leave over night.
Results 1 to 25 of 82