02-27-2013, 01:33 AM
Thread: Honeywell red link
by aircent1- Replies
- 2
- Views
- 223
There are no stoppers. This particular damper...
There are no stoppers. This particular damper has only two setscrews the lock the shaft in.
There are these 45deg and 60deg pins that can be installed into the damper motor, optional purchase,... -
02-26-2013, 11:58 PM
Thread: Honeywell red link
by aircent1- Replies
- 2
- Views
- 223
Honeywell red link
Anyone familiar with redlink mard8 vav.? I'm having problems with air leakage or bypassing damper blade in the 100% closed or "off zone" period. It's enough to overcool the space in a couple rooms...
-
05-20-2012, 02:53 PM
Thread: Leak detector recommendations?
by aircent1- Replies
- 36
- Views
- 2,675
Sounds like h10 is a winner! No complaints yet...
Sounds like h10 is a winner! No complaints yet from anyone
-
05-20-2012, 02:40 PM
Thread: H10pm leak Detector
by aircent1- Replies
- 3
- Views
- 890
Is the battery one just as good as the plug in...
Is the battery one just as good as the plug in version?
Looking into this h10 too, but need some pros and cons of which to get. -
02-29-2012, 08:49 PM
Thread: Mitsubishi city multi
by aircent1- Replies
- 4
- Views
- 655
I setup a conference call with him to run through...
I setup a conference call with him to run through setup with my client
He was very helpful. -
02-29-2012, 08:40 PM
Thread: Mitsubishi city multi
by aircent1- Replies
- 4
- Views
- 655
Thx anyway chuck, been there done that, called...
Thx anyway chuck, been there done that, called west region network tech today. He explained its too technical to explain over the phone and he agreed that their manuals are very thorough and...
-
02-29-2012, 07:39 PM
Thread: Mitsubishi city multi
by aircent1- Replies
- 4
- Views
- 655
Mitsubishi city multi
anyone familiar with the setup of the gb50 centralized controller?
could anyone breakdown the setup and network initial settings for me? setting up email error and online maintenance ? -
01-31-2012, 01:15 PM
Thread: trane techview
by aircent1- Replies
- 3
- Views
- 338
Thx nucl
Thx nucl
-
01-31-2012, 11:36 AM
Thread: trane techview
by aircent1- Replies
- 3
- Views
- 338
No one work with techview? Anyone?
No one work with techview?
Anyone? -
01-30-2012, 01:51 PM
Thread: trane techview
by aircent1- Replies
- 3
- Views
- 338
trane techview
Anyone with trane techview experience? I don't work for trane, but we use techview as a service tool to check control operations, logged chiller data.
I want to create log sheets directly from tv. ... -
12-22-2011, 09:33 PM
Thread: pillow block bearings
by aircent1- Replies
- 6
- Views
- 746
How about split case pump bearings?
How about split case pump bearings?
-
12-22-2011, 09:32 PM
Thread: pillow block bearings
by aircent1- Replies
- 6
- Views
- 746
pillow block bearings
At what temperature does bearing failure occur at?
-
10-24-2011, 02:17 AM
Thread: mitsubishi city multi fcu help!
by aircent1- Replies
- 8
- Views
- 888
Thx all, I used the manual, there is a set of Ohm...
Thx all, I used the manual, there is a set of Ohm readings that must be read to confirm proper operations
-
10-18-2011, 11:26 AM
Thread: Tracer Summit V15
by aircent1- Replies
- 18
- Views
- 853
Anyone ever worked with tracer es? Have any...
Anyone ever worked with tracer es? Have any comments?
-
10-18-2011, 01:28 AM
Thread: Tracer Summit V15
by aircent1- Replies
- 18
- Views
- 853
is this similar to tracer es :sev. pk 1??
is this similar to tracer es :sev. pk 1??
-
10-05-2011, 10:13 PM
Thread: mitsubishi city multi fcu help!
by aircent1- Replies
- 8
- Views
- 888
Someone had to of worked on this unit. Please help
Someone had to of worked on this unit. Please help
-
10-05-2011, 02:24 AM
Thread: mitsubishi city multi fcu help!
by aircent1- Replies
- 8
- Views
- 888
mitsubishi city multi fcu help!
Pefy p36 nmhu e
I found the Lev coil faulty and needs to be replaced.
Does anyone know if it can be replaced by accessing the side triangular panel? Or only through the bottom access panel? -
10-05-2011, 12:07 AM
Thread: help with dip switches- trane pkg unit
by aircent1- Replies
- 2
- Views
- 379
Thx controldude!
Thx controldude!
-
10-04-2011, 08:00 PM
Thread: help with dip switches- trane pkg unit
by aircent1- Replies
- 2
- Views
- 379
help with dip switches- trane pkg unit
Trane m#: Tch480a4oroa6kc5a
How should the dip switches be setup on the rtam board.
I would like to eliminate the ecomomizer from being used if possible. -
09-28-2011, 01:46 PM
Thread: honeywell damper actuator
by aircent1- Replies
- 8
- Views
- 462
Thanks davem
Thanks davem
-
09-28-2011, 01:15 PM
Thread: honeywell damper actuator
by aircent1- Replies
- 8
- Views
- 462
Here's the part ...
Here's the part
http://www.honeywellparts.com/4074eny-actuator-accessory-3-8.html
Now the actuator
http://www.amazon.com/gp/aw/d/B003CVV5SA/ref=redir_mdp_mobile
Any thoughts??? -
09-28-2011, 01:12 PM
Thread: honeywell damper actuator
by aircent1- Replies
- 8
- Views
- 462
Digo its weird bc when you look online, the...
Digo its weird bc when you look online, the picture they show is a 90 degree angle piece of metal. Doesn't look anything like the slot on the actuator where your supposed to insert.
-
09-28-2011, 12:23 PM
Thread: honeywell damper actuator
by aircent1- Replies
- 8
- Views
- 462
Thx all
Thx all
-
09-27-2011, 11:58 PM
Thread: honeywell damper actuator
by aircent1- Replies
- 8
- Views
- 462
anyone know how to go abot installing????
anyone know how to go abot installing????
-
09-27-2011, 02:57 PM
Thread: honeywell damper actuator
by aircent1- Replies
- 8
- Views
- 462
honeywell damper actuator
ML6161b2024 does anyone know how to keep.damper from opening up 100%, ?????I would like to make the max open at about 40-50% open instead of 100%.
Part #: 4074enj. Is that what it is used for???
Results 1 to 25 of 124