  1. Replies
    9
    Views
    1,956

    Toptech - Seems that P3 of the second to last...

    Toptech - Seems that P3 of the second to last bulletin you posted did not come through. This is very good stuff though.
  2. Replies
    12
    Views
    1,182

    Carrier's last absorber guru (Rich) is no longer...

    Carrier's last absorber guru (Rich) is no longer there.
  3. Replies
    3
    Views
    623

    Not a Standard JB

    Hint to would be responders: Contoller on the front of the panel is a UDC 3300, and panel has many more lights and relays than a North American built electric control JB.
  4. Replies
    89
    Views
    9,156

    Intelligent and frightening essay itsme!

    Intelligent and frightening essay itsme!
  5. Replies
    3
    Views
    623

    Slavakian built 16JB

    Anyone know where I can acquire a wiring diagram for a Slavakian built 16JB054? Have control panel issues and no diagram to be found.
  6. Replies
    10
    Views
    1,309

    Not much detail here, so this is a shot in the...

    Not much detail here, so this is a shot in the dark - got matched software?
  7. Replies
    117
    Views
    12,075

    Of course you're right about technological...

    Of course you're right about technological improvements. Needed to vent.
  8. Replies
    117
    Views
    12,075

    How 'bout tracking samples submitted?

    Technology is great! Look around and see what it's done for us. The more technology we get the harder it gets to accomplish anything. Cashiers can't make change during power outages. You can't...
  9. Replies
    7
    Views
    999

    YOU gotta leak test!

    99% chance your problem is one of two. Your pump crapped out or you got a leak. No where is it written that a newleak can't occur within seconds of a contractor fleeing the jobsite.
  10. Replies
    4
    Views
    850

    21 chillers employing HCFC-22?

    21 chillers employing HCFC-22?
  11. Replies
    15
    Views
    1,575

    Calling the GX a POS is being too kind. The HX's...

    Calling the GX a POS is being too kind. The HX's on the other hand are not bad and I would venture to say the water cooled version is actually good. Compressors are the same on all 3 versions, but...
  12. Replies
    47
    Views
    4,230

    The YT was and is a great chiller, just the purge...

    The YT was and is a great chiller, just the purge that sucks.[/QUOTE]

    So drivewiizard, would you please define a "great chiller" for us?
  13. Replies
    47
    Views
    4,230

    The world's worst purge will work satisfactorly...

    The world's worst purge will work satisfactorly on a tight machine!!! Seek and destroy the leak(s)!
  14. Replies
    13
    Views
    1,339

    Tecogen's are few and far between. From what I...

    Tecogen's are few and far between. From what I hear maintenance on the engines is a royal pain.
  15. Replies
    4
    Views
    897

    Start up went well. Got a little tripped up by a...

    Start up went well. Got a little tripped up by a half ton tank that apparently has a broken dip tube, but the chiller showed no signs of any compressor problems.
  16. Replies
    4
    Views
    897

    Thanks 007!!

    You know how they say misery loves company. Planning to roll it over tomorrow and hoping not be miserable, but it's good to know I'm not the first to experience this. Checked today to see how...
  17. Replies
    4
    Views
    897

    York "Magnetic" Personality

    Putting the finishing touches on the rebuild of the compressor on a 650t York YKPBNBH-CVC. (Replaced bearings and shaft seal) Today while reinstalling the various oil lines I discovered that the...
  18. Replies
    51
    Views
    4,143

    Jayguy - Thought by now somebody would have asked...

    Jayguy - Thought by now somebody would have asked the question, not about your name, but rather your location. Got anything to do with the October 1979, British art-punk band Wire release of a...
  19. Thread: CVHE

    by LGtonnagetech
    Replies
    37
    Views
    2,812

    Recently did a CVHE089 with a reluctant vane...

    Recently did a CVHE089 with a reluctant vane section. Fabricated a puller out of strip steel that we bent 90's on. Used 1/2" all thread inside a piece of pipe to keep the strips from drawing...
  20. Sounds like you have low tower water temp on...

    Sounds like you have low tower water temp on initial start. 23XL relies on cond press to return oil.
  21. Replies
    14
    Views
    1,382

    Got to wonder why

    DG & DM compressors are similar, but DM has that darned movable wall. Wonder if Carrier doubts compressors ability to make lift during slow acceleration.
  22. Replies
    12
    Views
    909

    Have to agree with heavymetaldad, if that is the...

    Have to agree with heavymetaldad, if that is the noise you hear and you have any sense, you run to the stop button.
  23. Replies
    34
    Views
    2,721

    Navair86-You'll have to keep guessing, but your...

    Navair86-You'll have to keep guessing, but your memory is pretty good. I do service absorbers. (not my first choice) In fact that's the reason the mechanical contractor I work for now hired me, so a...
  24. Stick to controls

    Orick, HCFC123 chillers are low pressure, and just because they run with a negative pressure doesn't mean they don't leak - distinction is that air goes from the outside in and the only refrigerant...
  25. Replies
    34
    Views
    3,114

    Don't get too excited!

    Absorbers have large shares of some big city chiller populations. Most notably New York and Chicago. They are not at all common in the boonies.
  26. Replies
    12
    Views
    1,060

    More work for you

    Just looked at the picture in a parts book and I think it will be obvious when you receive the new one that you've got a compressor teardown on your hands!
  27. Replies
    34
    Views
    2,721

    Because you asked for it

    Follow this link: http://www.epa.gov/ozone/downloads/HCFCDecision.pdf
    Print it out, and go find a good Philadelphia lawyer to translate!!!!!!!
  28. Reason not replaced?

    Can, Your pictures look like you got a professional conversion, but I'm curious why refrigerant conversion was selected over replacement. Was replacement an option considered? In this country the...
  29. Whadaya gonna save?

    Getting back to the original post questions. First, you most likely will have enough residual to set a quality, calibrated refrigerant monitor into alarm. How much time do you think you're going to...
  30. Why take a shortcut on this?

    RE-read step 2. (Purge is already isolated) Also, and especially in the case of HCFC123, you want to eliminate as much of the refrigerant as practical from the waste product before removal.
  31. Replies
    8
    Views
    857

    Although the dollars your office alotted for...

    Although the dollars your office alotted for hours might not be enough to cover the purchase of the tools you're going to need, you're in real trouble without them.
  32. Replies
    33
    Views
    2,383

    It's an old indian trick

    They're yanking your chain and/or not telling you the whold stroy.
  33. Replies
    11
    Views
    1,164

    19XR Nuisance Trips

    Chiller Mekinak,

    I know of a jobsite with 4-19XRs (2 PIC I and 2 PIC II) where the customer claims that one of the two newer ones runs fine when it runs alone, but when it runs with any of the...
  34. Replies
    159
    Views
    25,215

    Factory vs Independent

    I too should have been more clear. There's nothing that says service might not be performed by in-house staff. Also, there are many mechanics running service for themselves and independent shops...
  35. Replies
    159
    Views
    25,215

    Factory Service????????

    I would talk to your current serviceman, and possibly a couple of others in your area, manufacturer and refrigerant are not nearly as critical as being able to get GOOD service and parts (which...
  36. Replies
    339
    Views
    45,935

    Lgtonnagetech

    I'd tell you I left my heart in San Francisco, but I've never been there.
    Born in Chicago, IL and lived in the area ever since.
    Been in the HVAC game for more than 30 odd (emphasis on odd) years....