Search:

Type: Posts; User: aikenite

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Replies
    1
    Views
    159

    Ambient Technology

    I am having a problem with an ambient technology RCST control. I have done everything, replaced batteries, checked dip switch settings, etc.It seems the transmitter is not communicating with the...
  2. Thread: New Veto MC

    by aikenite
    Replies
    108
    Views
    10,831

    Got my MC bag today and I think it will be just...

    Got my MC bag today and I think it will be just what I wanted. It looks like it will hold just enough. Glad they chose to make it .
  3. Thread: New Veto MC

    by aikenite
    Replies
    108
    Views
    10,831

    I have the LC which I like ok.A little big to use...

    I have the LC which I like ok.A little big to use every day. I bought the MB and it is just not what I want. I think the MC is just what I need to be an every day troubleshooting bag.I only wish I...
  4. Replies
    14
    Views
    1,166

    I did replace the compressor and of course the...

    I did replace the compressor and of course the noise went away.I am going to try and cut the top off and see what I can find. One thing I did notice is there is no crankcase heater.I do plan on...
  5. Thread: magnet

    by aikenite
    Replies
    3
    Views
    681

    Had an e mail on Monday from Fieldpiece and they...

    Had an e mail on Monday from Fieldpiece and they sent me a new magnet right away.I like doing business with people that take care of their customers!
  6. Thread: magnet

    by aikenite
    Replies
    3
    Views
    681

    Thanks, I will try that.

    Thanks, I will try that.
  7. Thread: magnet

    by aikenite
    Replies
    3
    Views
    681

    magnet

    Does anyone know where you can get replacement magnet hangers for Fieldpiece meters?I have e-mailed them twice and they never responded.
  8. Replies
    14
    Views
    1,166

    The clicking is around every second and...

    The clicking is around every second and constant,no change up or down.I had thought about pulling the charge out and recharging the unit. Lucky this is a lead / lag system so this unit was made the...
  9. Replies
    14
    Views
    1,166

    It makes the noise the entire time it's running.

    It makes the noise the entire time it's running.
  10. Replies
    14
    Views
    1,166

    No I haven't.

    No I haven't.
  11. Replies
    14
    Views
    1,166

    compressor noise

    Working on a Bard wall hanger with a Copeland scroll ZR61K3 TF5 230 compressor that's making a clicking noise.The unit is still working but the noise coming from the compressor is pretty loud. I...
  12. Ive been using the stubby gauges for a couple...

    Ive been using the stubby gauges for a couple years now.I like them for quick checks on roof top units and I also like them for ice machines. Any thing that helps save time saves money too.
  13. Thread: my new job

    by aikenite
    Replies
    10
    Views
    826

    I am wanting to retire from my current job and go...

    I am wanting to retire from my current job and go to work for our school system.I need to continue to work but right now things stink where I am.I guess my biggest complaint is that I have to do all...
  14. Replies
    4
    Views
    487

    I agree that I like the Fieldpiece better than...

    I agree that I like the Fieldpiece better than the Supco.I have gotten spoiled with my S MANS and the built in vacuum gauge.For a stand alone meter I think I would like the Blue Vac.
  15. Replies
    6
    Views
    1,266

    Poll: Might try that and see if it helps,thanks

    Might try that and see if it helps,thanks
  16. Replies
    6
    Views
    718

    Could you give me the name so I can get one...

    Could you give me the name so I can get one myself? Thanks!
  17. Replies
    6
    Views
    1,266

    Poll: My uniweld does the same thing but I still like...

    My uniweld does the same thing but I still like it.Haven't had to change regulators yet.
  18. Replies
    6
    Views
    718

    Radio Shack has a test lead kit that has a...

    Radio Shack has a test lead kit that has a variety of different probes. They are around $22.00. there used to be a devise that you could hold next to a relay and it would cause a red light to come...
  19. Replies
    10
    Views
    1,603

    I have been using the Appion ball valves and mega...

    I have been using the Appion ball valves and mega flow manifold and hoses.I am disappointed in the valves though, I had one to separate. Was pulling a vaccum and noticed something was wrong, checked...
  20. Replies
    8
    Views
    1,022

    You're right but megging them worked out .

    You're right but megging them worked out .
  21. Replies
    8
    Views
    1,022

    I had a similar problem and I megged the motors,...

    I had a similar problem and I megged the motors, 1 was different than the other 3.Changed that motor and no more trouble. another unit that the wiring was in a trough and condensate was standing in...
  22. Thread: heat kit

    by aikenite
    Replies
    0
    Views
    292

    heat kit

    Does anyone have a drawing for the 15aoo heat kit?This is a 460 3 phase installation.The unit is a 50TC.I am using a single point box.
  23. Thread: DATA AIR

    by aikenite
    Replies
    10
    Views
    771

    yes, it says to pull a vacuum and add refrigerant...

    yes, it says to pull a vacuum and add refrigerant until it equalizes.Actually the co. says 3 lbs per ton plus the line set.I was just wondering how much for the piping. It also says to go for a 8-10...
  24. Thread: DATA AIR

    by aikenite
    Replies
    10
    Views
    771

    The unit was shipped empty.

    The unit was shipped empty.
  25. Thread: DATA AIR

    by aikenite
    Replies
    10
    Views
    771

    DATA AIR

    Doing start up on a Data Air DAAD2034. I need to know how much 410 for the line set, 20' 1and3/8 suction and 5/8 liquid line per circuit.
  26. Replies
    3
    Views
    618

    I like the Ford Transit myself.

    I like the Ford Transit myself.
  27. Thread: tool bag

    by aikenite
    Replies
    23
    Views
    3,114

    I like the CLC 1526 also.Have a Veto too but the...

    I like the CLC 1526 also.Have a Veto too but the CLC is my favorite.If Veto would copy it with a hard bottom it would be great. They would probably want an arm and leg for it though
  28. Replies
    35
    Views
    4,803

    I believe You might be on to something.With the...

    I believe You might be on to something.With the bead you're getting a pin point reading and the clamp would insulate it.I have been thinking about this ever sense I read it and I am definitely going...
  29. Replies
    10
    Views
    937

    Do you still use a coil gun to apply the...

    Do you still use a coil gun to apply the soap/water?
  30. Replies
    10
    Views
    937

    I wonder if this applies to package heat pumps?

    I wonder if this applies to package heat pumps?
  31. Replies
    10
    Views
    937

    Its been a while but I think so.I said recently...

    Its been a while but I think so.I said recently but it was actually last fall
  32. Replies
    10
    Views
    937

    cleaning coils

    We recently installed a Carrier chiller and the co says No coil cleaner on the condenser.Now my boss says no coil cleaner on the new 410 units.What about you guy's? I talked to one of our local parts...
  33. Replies
    35
    Views
    4,803

    I have used the 116 too but I hate having to use...

    I have used the 116 too but I hate having to use the adapter with the pipe clamp.I have had 2 to pull apart when I went to take the clamp out of my meter.I do try to take care of my equipment.Have...
  34. Thread: Klein tool

    by aikenite
    Replies
    4
    Views
    722

    Klein tool

    What about the KLein dual voltage detector? If it works ,it seems like a handy thing.I have read a lot of revues but they were'nt hvac techs ,so maybe we would have a different point of view.
  35. Replies
    35
    Views
    4,803

    Is the fieldpiece ssx a good investment?I have...

    Is the fieldpiece ssx a good investment?I have been thinking about buying one but I have not ever talked to anyone that has one.
  36. Replies
    9
    Views
    800

    I meant low ohms ,I said continuity,sorry

    I meant low ohms ,I said continuity,sorry
  37. Replies
    9
    Views
    800

    Whats the best way to clean the probe?The service...

    Whats the best way to clean the probe?The service manual mentions ohming the probe.Is this just to be sure there is continuity?
  38. Replies
    9
    Views
    800

    Manitowoc s machine

    Checked a Manitowoc S420 machine and it has no water flowing to the trough.There is water coming to the valve.Checked voltage at the plug going to the valve and only had 5 volts.Took a cheater cord...
  39. Thread: Nut Drivers

    by aikenite
    Replies
    47
    Views
    9,457

    I still use my Xcelite 99 service kit and love...

    I still use my Xcelite 99 service kit and love it. The nut drivers are great.
  40. Replies
    13
    Views
    2,000

    non contact voltage detector

    Saw a new duel voltage non contact detector at H D made by KLEIN.Anyone tried one yet?
  41. Replies
    12
    Views
    2,508

    I bought my Fluke 16 for $35.00 at a pawn shop...

    I bought my Fluke 16 for $35.00 at a pawn shop several years ago.Also got my megger and some spare oxy/acet bottles. Have not seen many ''deals'' in quite some time though.
  42. Thread: Tool bags

    by aikenite
    Replies
    96
    Views
    17,672

    I'll have to say that's a pretty neat bag.Our...

    I'll have to say that's a pretty neat bag.Our Sears is too small to carry much. I have not seen one of these before.
  43. Replies
    204
    Views
    32,844

    I have a Fenix PD22 and it is one handy...

    I have a Fenix PD22 and it is one handy light.Three settings and on high it is really bright.Small enough to carry in your pocket.A great little light!
  44. Thread: Tool bags

    by aikenite
    Replies
    96
    Views
    17,672

    I have a lot of different tool bags/boxes...

    I have a lot of different tool bags/boxes including a Veto lc and I seem to always go back to the CLC 1526.I like having everything where I can see it.As far as carrying it by the shoulder strap ;I...
  45. Replies
    31
    Views
    7,201

    I wasn't looking for bad bearings, that was just...

    I wasn't looking for bad bearings, that was just something that I did notice about the motor.As far as being conclusive the unit is working fine ,that's good enough for me.There are times when you're...
  46. Replies
    31
    Views
    7,201

    On a carrier 50tc there are 4 condenser fans.They...

    On a carrier 50tc there are 4 condenser fans.They are fed by 15 amp fuses The fuses had blown several times and other guys would just replace the fuses and it would work for a day or two.I decided to...
  47. Replies
    31
    Views
    7,201

    I recently used mine to find a bad condenser...

    I recently used mine to find a bad condenser motor that read o k with a meter.I will admit that i don't use it often,but in this case it saved the day!
  48. Thread: ADDISON

    by aikenite
    Replies
    2
    Views
    654

    You were right.I e-mailed them and they sent me...

    You were right.I e-mailed them and they sent me the info.Unit is back in service! Thanks!
  49. Thread: ADDISON

    by aikenite
    Replies
    2
    Views
    654

    ADDISON

    I need help with a wiring diagram for an ADDISON M#SCA041S03A. S# 020804601001. I would appreciate any help!
  50. Thread: Fieldpiece

    by aikenite
    Replies
    133
    Views
    22,117

    I bought an HS36 and have really enjoyed it.My...

    I bought an HS36 and have really enjoyed it.My complaint is with the alligator leads.They are too short to use by themselves on most cases and the angle plugs connected to the other leads makes for a...