  1. Replies
    20
    Views
    1,422

    I'd rather not be censored for one. There was...

    I'd rather not be censored for one. There was nothing "war" starting in that post just hard truths. The pros forum doesn't allow for helping a h/o and I saw no one else sugest his emergency heat just...
  2. Replies
    20
    Views
    1,422

    Maybe you should have left that post for a while

    Maybe you should have left that post for a while
  3. Replies
    15
    Views
    1,334

    Sounds like the defrost is set to 30 mins which...

    Sounds like the defrost is set to 30 mins which is 30mins of run time if the unit isn't working right and it doesn't sound lime it is then it's running nonstop so that is every 30 mins. It sounds...
  4. Replies
    20
    Views
    1,422

    S1 &S2 are for on outdoor sensor only and if...

    S1 &S2 are for on outdoor sensor only and if those two wires from the stst do infact go to a sensor then the stat is not programed right. If you have back-up heat I would sugest putting the stat on...
  5. Replies
    30
    Views
    1,462

    Better to be thought a fool than to open your...

    Better to be thought a fool than to open your mouth and remove all doubt. right? just shows that there are "techs" everywhere that are going about this all wrong and those who really need to educate...
  6. Replies
    30
    Views
    1,462

    well its sad to think you have the customer in...

    well its sad to think you have the customer in mind when you clearly dont. i do service and sales and pms and installation when need be the point is to give the homeowner what they need not what you...
  7. Replies
    35
    Views
    1,788

    You'll need backup of some kind, as heat pumps...

    You'll need backup of some kind, as heat pumps poop out I hear when it gets 45 to 50 and below. Cause there's no heat out there to bring inside

    there is heat in the outdoor air down well below...
  8. Replies
    4
    Views
    492

    No electrian call a service tech from your HVAC...

    No electrian call a service tech from your HVAC company. they will tell you what t-stat you need and be able to install it for you. some systems are easy for a homeowner yours is not
  9. Replies
    30
    Views
    1,462

    have you never seen a contactor lock up leo?...

    have you never seen a contactor lock up leo? update you profile i'd love to know how long youve been doing this and where. Maybe they need a test to get pro status
  10. Replies
    30
    Views
    1,462

    well you are either the boss or supertech cause i...

    well you are either the boss or supertech cause i dont know one guy that does no pm's. clean the end shot burners not, crossovers YES, flamesensors YES... entire furnace YES guess thats why my...
  11. Replies
    30
    Views
    1,462

    No leo you stated that it gas furnace needs to be...

    No leo you stated that it gas furnace needs to be checked for proper venting and nothing more. "any vented gas fired appliance should be checked for proper venting before winter ". Do you just...
  12. Replies
    30
    Views
    1,462

    You should be ok to go the first year with no...

    You should be ok to go the first year with no maintence...should be... wouldnt be bad idea to have furnace checked before heat though. Dont think any manufacturers have rules as to what sould be done...
  13. Replies
    30
    Views
    1,462

    Sorry leo gotta disagree on that one lot more to...

    Sorry leo gotta disagree on that one lot more to a pm than filter change. dont work for somebody whos just out for $$$$$$$$$. Dont like to agree with raiders fans usually:D but there is lots to be...
  14. Replies
    30
    Views
    1,462

    I must be missing something here. you said most...

    I must be missing something here. you said most modern systems are maintence free Leo then why do they do them what is 1/2 of my work load for? As far as on a brand new system it probablly wont need...
  15. Replies
    3
    Views
    483

    EAC's are ok if you clean them alot the media...

    EAC's are ok if you clean them alot the media cartridge is a good replacment but have a cost everytime they need to be changed- some like the merv 16 can get costly. there is a 1" electronic filter...
  16. Replies
    15
    Views
    1,298

    I'd have to look at my book but i'm pretty sure...

    I'd have to look at my book but i'm pretty sure the IAQ will do it on time or temp
  17. Replies
    10
    Views
    750

    replaced switch didint work. used manometer, all...

    replaced switch didint work. used manometer, all not so ok. i know the inducer is the wrong one just trying to figure out why this problem happened when it was brand new with correct inducer and...
  18. Replies
    10
    Views
    750

    what i know is that i went for a pm. first thing...

    what i know is that i went for a pm. first thing i did was remover the burner door, clean flame sensor ect.. when i went to fire it off i noticed water in the pres switch and up the vent into gas...
  19. Replies
    10
    Views
    750

    Here, we can not answer...please apply for pro...

    Here, we can not answer...please apply for pro status.

    waiting for new copy of epa card old one did not scan well enough to attach to pro ap.
  20. Replies
    10
    Views
    750

    think you missed it there I am the tech. The...

    think you missed it there I am the tech. The unit was a hack install that had many other problems and th h/o has opted to replace it. Just thought it was a weird one and wanted to get some ideas,...
  21. Replies
    10
    Views
    750

    Trane poltergist

    OK I have one. 9 year old trane 90% furnace will not fire off with the intake on- intake is clear. if you take the burner compartment door off or intake off it fires up. inducer has been replaced at...
  22. Replies
    26
    Views
    1,377

    depends on the system. could be variable speed in...

    depends on the system. could be variable speed in which case cfm can be adjusted or you may have three or four speed taps. high speed is usually reserved for cooling
  23. Replies
    15
    Views
    888

    Lennox makes a solid heat pump especially their...

    Lennox makes a solid heat pump especially their higher end stuff but then again evryones higher end units seem to be really strong.I know Lennox has a lifetime warranty on their compressor in some of...
  24. Replies
    53
    Views
    2,228

    no, no its not but atleast he isnt telling you to...

    no, no its not but atleast he isnt telling you to stick duct board up your nose
  25. Replies
    53
    Views
    2,228

    I think I might have someone else look at it....

    I think I might have someone else look at it. Lots of stuff there to go wrong or be set wrong. Common back to dehum2??? dunno about that one