Search:

Type: Posts; User: COOLJIM

Page 1 of 9 1 2 3 4

Search: Search took 0.03 seconds.

  1. Replies
    11
    Views
    455

    whoops surfer

    whoops surfer
  2. Replies
    11
    Views
    455

    helped me . a super web suffer

    helped me . a super web suffer
  3. Replies
    17
    Views
    631

    oil is not that color normally, we used to hang...

    oil is not that color normally, we used to hang the compressor from its foot on a meat hook angled to a drain point on the suction , if u flush let it drain that way , and yes drain or replace the...
  4. Thread: Recent install

    by COOLJIM
    Replies
    50
    Views
    2,569

    you said dual fuel ? , as in heat pump and nat...

    you said dual fuel ? , as in heat pump and nat gas , if heat pump needs pump up legs , if a/c my bad
  5. Replies
    9
    Views
    446

    had a very similar problem , went on for a while...

    had a very similar problem , went on for a while , eventually , it was a relay , not the water control one , we always had water . it was a 12 v coil , there are 3 or 4 relays, water, auger , power...
  6. Replies
    6
    Views
    508

    low temp scroll compressor , freezer operation ....

    low temp scroll compressor , freezer operation . you have liquid feed to the valve, which is sensing compressor discharge heat via the valves bulb mounted in the well of the compressor dome . injects...
  7. Replies
    17
    Views
    631

    sound like the oil may be a / the problem , may...

    sound like the oil may be a / the problem , may have to drain the oil , or is it moisture that is causing the blockage ?. if you capture some oil put it in a sealed glass jar , and let it sit in a...
  8. Replies
    2
    Views
    458

    dont forget to insure the machines ,your property...

    dont forget to insure the machines ,your property in other peoples locations
    an old friend had a lot of refrigeration in a huge food market ,collecting monthly rent . along came a fire wiped him...
  9. Replies
    31
    Views
    991

    my truck is stocked only with 440 -volt...

    my truck is stocked only with 440 -volt capacitors , as 440 can be used in place of 370 volt,
  10. The UK will survive and may be thrive again , but...

    The UK will survive and may be thrive again , but there will be financial consequences , currency , jobs, investment , taxes .
    political , Scotland may seek to leave the union , northern Ireland...
  11. Thread: Leak Detection

    by COOLJIM
    Replies
    16
    Views
    804

    after the recommendations here , i am going to...

    after the recommendations here , i am going to try snoop, often disappointed with big blue type of leak spray , just to many bubbles sitting there , to detect a small leak .
  12. Replies
    15
    Views
    638

    suction pressure on harvest is Low

    suction pressure on harvest is Low
  13. Replies
    16
    Views
    610

    I had a similar compressor go down , on a 2 door...

    I had a similar compressor go down , on a 2 door traulsen freezer this Friday aha2435axd I size down from yours 3400 btu at -10f cap tube ,checked the price nearly 800, but amazingly still...
  14. Thread: Ali

    by COOLJIM
    Replies
    35
    Views
    926

    Not a saint , but an inspiration to many , voted...

    Not a saint , but an inspiration to many , voted World sportsman of the century in 1999 I think . He has been quiet for so many years due to his debilitating illness , I wonder what his legacy would...
  15. the customer , had said he noticed the evap...

    the customer , had said he noticed the evap getting real hot a few times , but when he checked later it was freezing , heaters need more clips as some have moved out of there correct space , that...
  16. W I Freezer , sprinkler head blew out . Twice

    We get a call , telling us the sprinkler head in the freezer blew out , flooded the premises , fire brigade helped in clean up .
    Head repaired restarted freezer , same thing happened next day . now...
  17. Thread: beacon 2

    by COOLJIM
    Replies
    9
    Views
    500

    OK ,Solved, first push in contactor and pump...

    OK ,Solved, first push in contactor and pump down system , this removes the fault code on the transducer, then after much testing found the real cause , a bad coil in the compressor contactor was...
  18. Thread: beacon 2

    by COOLJIM
    Replies
    9
    Views
    500

    correct about the transformer, they had it on the...

    correct about the transformer, they had it on the 240 tap (default) so I corrected that to the incoming 208v. the 3 temp sensors were accurate , tested those. checked the suction pressure which was...
  19. Thread: beacon 2

    by COOLJIM
    Replies
    9
    Views
    500

    beacon 2

    my first service call on beacon 2 , its just sitting there flashing OFF then the temp, occasional e 4 or a 4
    is displayed. one is transducer , .
    also the led goes to 888 then goes blank and...
  20. Replies
    0
    Views
    164

    agricultural building , / part conversion

    A large horse barn is to be converted to part garage /office . 40 wide 36 ft deep will be made to store some cars , and an office are ,
    the remaining 160 0f barn will remain agricultural .
    a...
  21. Replies
    6
    Views
    475

    Log Home insulation

    do logs have good insulation value , home is 1550 sq ft , A frame roof, windows are dual glazed , there is a basement which is to become a conditioned space , vents will be up flow from the basement...
  22. Thread: indigo issue

    by COOLJIM
    Replies
    14
    Views
    592

    I have not been back to site yet , when I do i I...

    I have not been back to site yet , when I do i I will have a water sensor, an itp , and a board . when I powered up on a couple of occasions the unit instantly went to hpco, 60 minute wait , i...
  23. Thread: indigo issue

    by COOLJIM
    Replies
    14
    Views
    592

    correct does not wipe out logged history of...

    correct does not wipe out logged history of events , but does remove stored history of the last 5 ice drops , safe mode refers to this history and runs production for 72 hrs until a tech is called....
  24. Thread: indigo issue

    by COOLJIM
    Replies
    14
    Views
    592

    water level is my first check on Monday I did...

    water level is my first check on Monday I did remove and clean it last visit , will take 1 to site and an itp , try n resolve it. This model is under warranty , our company won't do Manitowoc...
  25. Thread: indigo issue

    by COOLJIM
    Replies
    14
    Views
    592

    yes use the panel to check the hertz as well ,...

    yes use the panel to check the hertz as well , this machine is really is really a PIA, goes to safe mode , but then switchs off , because I turned it off , this wipes out logged history, so cant...
  26. Thread: indigo issue

    by COOLJIM
    Replies
    14
    Views
    592

    indigo issue

    IY 1404a. approx. 18 mt old . any one know the board leds . at the top left there are 4 leds , when does the ITP (microphone in thus case)
    illuminate. and then not illuminate ? . any real good...
  27. Replies
    14
    Views
    6,523

    On a farm job , geese (fat one) settled in to a...

    On a farm job , geese (fat one) settled in to a open drive unit , when unit started the goose was splattered all over the plant room , blood and guts everywhere , even broke the fly wheel . a...
  28. Replies
    3
    Views
    667

    low temp scrolls , use that location to place...

    low temp scrolls , use that location to place sensor attached to a valve providing liquid injection to compressor .
  29. Thread: R22 Phase out

    by COOLJIM
    Replies
    28
    Views
    1,270

    galt , your not crazy , r32 is now being used in...

    galt , your not crazy , r32 is now being used in many world markets , a future substitute for 410a , may be a little time before it cracks the usa market though
  30. Thread: R22 Phase out

    by COOLJIM
    Replies
    28
    Views
    1,270

    Is it illegal to mix refrigerants ?. Have...

    Is it illegal to mix refrigerants ?. Have recharged a percentage mix of 134a & 404a in thermo scientific freezers . as per the manufacturers label .
  31. Replies
    47
    Views
    3,163

    YOU know the mods lol

    YOU know the mods lol
  32. Replies
    42
    Views
    3,365

    Bigger Pockets.com is a great resource for all...

    Bigger Pockets.com is a great resource for all renting, buying, flipping, info , on a par with this site , lots of activity .
  33. Thread: Green oil?

    by COOLJIM
    Replies
    9
    Views
    498

    DO tell us

    DO tell us
  34. Replies
    10
    Views
    644

    very cool piece of engineering , easy on the eye.

    very cool piece of engineering , easy on the eye.
  35. Replies
    63
    Views
    2,075

    Interesting info from this thread , good work...

    Interesting info from this thread , good work ddcsd
  36. remove flares braze in fittings , use nitro to...

    remove flares braze in fittings , use nitro to prevent oxidization
  37. Replies
    45
    Views
    2,112

    I have similar had similar results with the bc2...

    I have similar had similar results with the bc2 cap tube , last time I used it with same set up as you , I cut to 65 inch and think that was still to restrictive , will try a little less length next...
  38. Replies
    3
    Views
    390

    use a trap for oil on the suction rise to the...

    use a trap for oil on the suction rise to the roof , solenoid valve to prevent liquid crossover in the off cycle . install a accumulator before the compressor , if the unit does not have pressure...
  39. Thread: That job thing

    by COOLJIM
    Replies
    21
    Views
    1,319

    happy birthday Lytning and congratulation'son...

    happy birthday Lytning and congratulation'son your long career. jim
  40. Replies
    3
    Views
    303

    A duvet , Scandinavia and north Europeans ,...

    A duvet , Scandinavia and north Europeans , snuggle in great comfort. just a sheet and a good duvet
  41. Replies
    18
    Views
    1,298

    the kits with relays , are used to stop the...

    the kits with relays , are used to stop the compressor load welding the stats contacts.
  42. Replies
    7
    Views
    1,869

    lol, I am from the uk and a tundish is a term...

    lol, I am from the uk and a tundish is a term used to describe a collection vessel for drains etc. ,often used to provide an air gap for plumbing regs etc., , the first time I used the term at a...
  43. Replies
    36
    Views
    1,696

    are all manitowocs now made in mexico and china .

    are all manitowocs now made in mexico and china .
  44. Replies
    10
    Views
    530

    its a struggle, I was sent to help a fellow the...

    its a struggle, I was sent to help a fellow the who was tearing his hair out ,lol . the grease will be a big help , good luck
  45. Replies
    1
    Views
    558

    inspection mirror

    read a post here a while back about inspection mirrors n replacement glass , mine get cracked a lot . found 10 x2 inch dia mirrors , for $2.47, a bargain lol from hobby lobby .
  46. Replies
    2
    Views
    533

    changed the fuses , but never knew why they blew...

    changed the fuses , but never knew why they blew lol. nice find
  47. Replies
    19
    Views
    4,861

    x 2, thanks

    x 2, thanks
  48. are you reading from the true suction port

    are you reading from the true suction port
  49. freezer repair on a facility that stored frozen...

    freezer repair on a facility that stored frozen dead bodies , all wrapped in a cling wrap I suppose, I open the door could not get to evap for the bodies or partial body pieces , it was a weird...
  50. Replies
    152
    Views
    34,547

    A quality flare tool for making braise free...

    A quality flare tool for making braise free connections , is that still a consideration .
Results 1 to 50 of 402
Page 1 of 9 1 2 3 4