    The Freon name is actually still alive and quite...

    The Freon name is actually still alive and quite well.
    https://www.chemours.com/Refrigerants/en_US/products/Freon/:det:
  2. Replies
    56
    Views
    4,320

    Looking at picture #2 those stub outs look like...

    Looking at picture #2 those stub outs look like they could be a type of orficed check valve. Restricting hot gas just enough to keep compressor happy. I guess controlled by suction pressure or temp....
  3. If memory serves me right, I think Data Aires had...

    If memory serves me right, I think Data Aires had the copelands with the rotolock connections. Mabe?
  4. Replies
    19
    Views
    4,338

    Hi davem, would you please shoot me a copy also....

    Hi davem, would you please shoot me a copy also. TIA!
  5. Thread: PCG Units

    by PortaChill
    Replies
    6
    Views
    576

    Can you post the series and model number for this?

    Can you post the series and model number for this?
  6. Yep They all had nicknames. Even us...

    Yep They all had nicknames. Even us techs/mechanics. We were the primadonnas showing up on the jobsite wearing uniforms, clean cut pocket protector all ready for critique or praise of our fellow...
  7. When I was cutting my teeth the journeymen used...

    When I was cutting my teeth the journeymen used the term" Stupid Wire Pullers". This was for all electricians.


    " I'm a licensed master electrician"
  8. Sticky: Dad, sorry this is coming so late but I am very...

    Dad, sorry this is coming so late but I am very sorry for your loss. Prayers and well wishes to you and your family for the future. And also a big thank you for your effort of keeping this site the...
  9. Replies
    7
    Views
    794

    X2 for sure.

    X2 for sure.
  10. Replies
    14
    Views
    1,115

    Where does she dance at??:oops

    Where does she dance at??:oops
  11. Besides checking the oil screen and sump for...

    Besides checking the oil screen and sump for pieces, don't forget the muffler if it has one. I once had a Carlyle that busted up and sent small pieces into the muffler and rattle canned that thing...
  12. Replies
    29
    Views
    4,898

    I am with taheem on this one. I learned thru...

    I am with taheem on this one. I learned thru trial and frustration to cut the valve out first. You can bench weld the valve at once and have room to get good flow around the joints.( Even on top of...
  13. Replies
    10
    Views
    1,505

    Fan Curve, your 6L45 is actually a 06L209 Carlyle...

    Fan Curve, your 6L45 is actually a 06L209 Carlyle semi hermetic 4 cyl. based on the 5H open drive compressor design. Three cylinders will load/unload. If your vibration is coming after your last...
  14. Replies
    62
    Views
    6,727

    Hi there Carbon. Do you know what the actual...

    Hi there Carbon. Do you know what the actual equipment was they were rigging onto that floor? Lots of guessing as to what exactly was being lifted. Curious minds want to know for sure.
  15. Thread: It's a tech

    by PortaChill
    Replies
    18
    Views
    1,889

    Congrats Chase!! May his life be happy and...

    Congrats Chase!! May his life be happy and blessed!!
  16. Replies
    20
    Views
    1,088

    Well put Hugh!!!

    Well put Hugh!!!
  17. Replies
    16
    Views
    1,726

    On that compressor you can't just turn the center...

    On that compressor you can't just turn the center head around. You will need the proper center head whether front or rear discharge.The head suction/discharge separation casting is different for that...
  18. Replies
    28
    Views
    2,617

    Had the same thing happen some years ago. luckily...

    Had the same thing happen some years ago. luckily company stepped up and replaced everything like for like or better. Try to push your company to step up to the plate.
  19. Replies
    103
    Views
    17,589

    My thoughts and prayers for a full and speedy...

    My thoughts and prayers for a full and speedy recovery for you Mr Bill!!!
  20. Replies
    10
    Views
    1,500

    I really feel bad for your son. I do hope that he...

    I really feel bad for your son. I do hope that he will recover soon. Look at the library pages on this site, maybe an answer somewhere in their docs.

    http://www.h2o2.com
  21. Replies
    32
    Views
    7,569

    Don't be so hard on the poor guy... At least is...

    Don't be so hard on the poor guy... At least is looks like he left some nice cardboard diagrams for you to follow!!
  22. Replies
    117
    Views
    13,018

    A lot of Lieberts with the motor master option...

    A lot of Lieberts with the motor master option use a 460v single phase motor for speed control while the other fans are three phase.
  23. You are correct rundawg. Thanks for the lit.

    You are correct rundawg. Thanks for the lit.
  24. That unit is a 50QQ heat pump. Serial number says...

    That unit is a 50QQ heat pump. Serial number says 1982 Those ranged from 1.5-5 tons.
  25. Replies
    4
    Views
    1,291

    Looks to be 25 ton chilled water upflow.

    Looks to be 25 ton chilled water upflow.
  26. Replies
    31
    Views
    3,408

    with that low of amperage you should be fine....

    with that low of amperage you should be fine. They probably used #12 solid for wiring. Just verify your actual voltage and size heaters accordingly. It would still be best to make this just a...
  27. Replies
    12
    Views
    1,760

    Looks to be 1962 ...

    Looks to be 1962



    http://www.buildingcenter.org/system/files/userfiles/images/BRYANT%20Serial%20Number%20Style%205.jpg
  28. Replies
    12
    Views
    1,662

    Check with samsung. I know that fujitsu sells...

    Check with samsung. I know that fujitsu sells high humidity insulation kits for their cassette.
  29. Replies
    16
    Views
    2,412

    As others have stated, snubber capasitors.

    As others have stated, snubber capasitors.
  30. Replies
    57
    Views
    6,450

    Did you verify the condenser fan motor was...

    Did you verify the condenser fan motor was spinning correct rotation? A faulty capasitor can cause it to spin in reverse. Or is it just recycling hot air thru it since you said it had alot of...
  31. Replies
    53
    Views
    4,013

    Dad, since the OP has now apologized can we get...

    Dad, since the OP has now apologized can we get this thread closed. No need for others to pile on...
  32. Replies
    11
    Views
    1,640

    Actually you were correct with your...

    Actually you were correct with your first(Shorted) post. I have a diagram but can't seem to upload it. Looks as if you have it handled though.
  33. Replies
    30
    Views
    3,850

    my guess is that there is a motorized fire damper...

    my guess is that there is a motorized fire damper in each supply drop in that combo plenum. They would all be daisy chained together, spring return closed with loss of power to them. Another reason...
  34. Replies
    43
    Views
    3,322

    I am glad this was finally mentioned!!! Good call...

    I am glad this was finally mentioned!!! Good call PHM. Also something to add, not knowing how much oil has been added over time I would assume that the refrigerant is "oil Saturated" not enabeling...
  35. Replies
    14
    Views
    1,543

    Need more info, Model# are these ducted...

    Need more info, Model# are these ducted systems,downflow,top plenum discharge?. They come with adjustable sheaves from the factory.
  36. Replies
    33
    Views
    3,247

    I also remember using R11 to flush out DX piping...

    I also remember using R11 to flush out DX piping on larger system installs.
  37. Just to use as a reference, The trane voyager...

    Just to use as a reference, The trane voyager uses the same blower wheel from 17-25 ton units. Not the same fan rpm as your system(still need to provide M&S numbers...)
  38. Replies
    8
    Views
    1,412

    If the compressor was insulated and the mud and...

    If the compressor was insulated and the mud and moisture rot makes me think that thing sat under water at some point in it's life.
  39. X2 Here.

    X2 Here.
  40. Replies
    5
    Views
    2,159

    Good thing is that it looks like there is enough...

    Good thing is that it looks like there is enough room to raise that thing and build a return platform. Definitely falls under
    hack category...
  41. Replies
    4
    Views
    580

    No schematic on one of the panels? Are you a...

    No schematic on one of the panels? Are you a tech.? Don't want to come across as an ass but this is 101 stuff. The transformer label should tell you what those leads are(primary,secondary). We can't...
  42. Replies
    17
    Views
    2,029

    My mistake...Foot in mouth syndrome:whistle:

    My mistake...Foot in mouth syndrome:whistle:
  43. Replies
    17
    Views
    2,029

    Have you verified your run cap is good? Could be...

    Have you verified your run cap is good? Could be causing compressor motor to labor more.
  44. Replies
    5
    Views
    1,285

    Give this a try 491821

    Give this a try

    491821
  45. Thread: Retired

    by PortaChill
    Replies
    6
    Views
    1,248

    When i was cutting my teeth(mid 80's). If we came...

    When i was cutting my teeth(mid 80's). If we came across a R500 Carrier they had us size down the TXV
    2-3 tons smaller and then charge with R22.
  46. Replies
    14
    Views
    1,490

    Here is some PSIO info I had. 491061

    Here is some PSIO info I had.
    491061
  47. Replies
    15
    Views
    1,441

    Got a chuckle out of this one...

    Got a chuckle out of this one...
  48. If it has served its purpose,maybe would be best...

    If it has served its purpose,maybe would be best to cut it out and straight pipe it. If you feel you need it in the system
    then the 56% route would be best. If you do replace it,at least all the...
  49. Replies
    15
    Views
    1,347

    Is there any space between the condo units where...

    Is there any space between the condo units where you could run square or round duct? Have it enclosed with a
    stucco or sided soffet wall. Size your exhaust fans to be able to either draw or...
  50. Replies
    27
    Views
    2,928

    dlu, What you are are claiming as the "smudgy...

    dlu, What you are are claiming as the "smudgy oil" is probably soap bubble leak detector residue. It will make that carbon from the poor brazing job turn into a goo type mess.