Search:

Type: Posts; User: kevincompass

Page 1 of 4 1 2 3 4

Search: Search took 0.01 seconds.

  1. Thread: SORIT 12

    by kevincompass
    Replies
    8
    Views
    196

    I use this very set up for cds 9 and 7 valves ...

    I use this very set up for cds 9 and 7 valves works great
  2. Replies
    19
    Views
    993

    sump pump and a garbage can work good

    sump pump and a garbage can work good
  3. Replies
    19
    Views
    993

    Water nothing faster

    Water nothing faster
  4. Replies
    12
    Views
    527

    Leak lock is garbage I can't stand it when guys...

    Leak lock is garbage I can't stand it when guys put that stuff on equipment gets everywhere and is a pain to get apart nulog and teflon all the way.
  5. Replies
    687
    Views
    53,210

    So are we ever going to see multiple superheats...

    So are we ever going to see multiple superheats off one lp probe
  6. Replies
    6
    Views
    314

    Put a defrost clock on if your worried about oce...

    Put a defrost clock on if your worried about oce ups the way its set up causes it to run warm at times t stat is much better control
  7. Replies
    6
    Views
    314

    If it's a pump down system set the cut in below...

    If it's a pump down system set the cut in below the coldest ambient you will see many ci 20 co10
  8. Well I am sure it was over amping at 35/335 that...

    Well I am sure it was over amping at 35/335 that is high even with a warm box
  9. Replies
    687
    Views
    53,210

    K thanks Jim I do a lot of supermarket start ups...

    K thanks Jim I do a lot of supermarket start ups and this would cut down on start up time in a big way and I'm my opinion the only thing holding it back from being perfect
  10. Replies
    687
    Views
    53,210

    So how far off are we from several superheats off...

    So how far off are we from several superheats off one pressure sensor
  11. Replies
    12
    Views
    1,073

    What u want for the probes

    What u want for the probes
  12. Replies
    9
    Views
    541

    No need for a pencile heater that is not what the...

    No need for a pencile heater that is not what the OEM has designed just keep that drain clear and you be fine
  13. Replies
    9
    Views
    541

    They only have pan heaters with hot gas the coil...

    They only have pan heaters with hot gas the coil heater keeps it warm enough to drain out have you checked drip time or correct defrost times and termination many the drain was just plugged
  14. Replies
    687
    Views
    53,210

    Jim is there a way to see all the info from the...

    Jim is there a way to see all the info from the wireless sensors and from the 4 sensors on the I connect in one screen .If not this would be very hepfully for diagnostics. Also can you set up a...
  15. Check out parasence they offer all of this with...

    Check out parasence they offer all of this with remote mothering http://www.parasense.com/monitor.html
  16. Replies
    20
    Views
    2,141

    Looks good when are we going to get the ability...

    Looks good when are we going to get the ability to do multiple superheats off one transducer
  17. You can get them I have had to order one before...

    You can get them I have had to order one before its outrageously overpriced
  18. Replies
    7
    Views
    693

    Its more thin likely a baud rate issue change it...

    Its more thin likely a baud rate issue change it in device manager
  19. Replies
    15
    Views
    2,489

    Well now ur getting in to lieabity if ur repair...

    Well now ur getting in to lieabity if ur repair fails its on you if ur oem part has an issue it don't look as bad also most of these valves are factory welded with every big name mfg Sporlan is...
  20. Replies
    15
    Views
    2,489

    Nope never a fix just Cary spair orings its a hot...

    Nope never a fix just Cary spair orings its a hot cold issue causes gaskets to expand and contract
  21. Replies
    687
    Views
    53,210

    OK Jim do you have a lead time on the single...

    OK Jim do you have a lead time on the single sensor set up its prity much the last thin holding the I connect from being bullit prof .
  22. Replies
    687
    Views
    53,210

    Jim I updates this morning how do I use the...

    Jim I updates this morning how do I use the mautpule superheats / multiple compressor opperstion
  23. Replies
    687
    Views
    53,210

    Jim if this is the case if its a couple psi off...

    Jim if this is the case if its a couple psi off I would still like the ability to zero my probes all transducers eventually will read off
  24. Replies
    687
    Views
    53,210

    it was reading a vacuum at atmospheric pressure I...

    it was reading a vacuum at atmospheric pressure I tried to zero it when I went to the zero probe option it says there's pressure on probe remove pressure before zeroing probes and it wont let me zero...
  25. Replies
    687
    Views
    53,210

    imperial sent me a new probe I have to send the...

    imperial sent me a new probe I have to send the old one back I was just checking oil pressures and it just started reading off and was In a vaccume after that . I would really like to see the ability...
  26. Replies
    687
    Views
    53,210

    Has any one had wireless transducers fail I used...

    Has any one had wireless transducers fail I used my high side 2 times checking oil pressure and it stopped working just kept reading 10 hg also how can I read several superheats off one pressure like...
  27. Replies
    687
    Views
    53,210

    Jim I noticed the wireless transducers only go...

    Jim
    I noticed the wireless transducers only go down to 14 hg of a vaccume on the package will they be damaged if brought down lower thin that
  28. Replies
    687
    Views
    53,210

    Jim when will be able to do several superheats...

    Jim when will be able to do several superheats off one input and several temp sensors I just got my I connect I love it but when Iam starting up stores I may have to ajust 5 txvs at one time this...
  29. Replies
    687
    Views
    53,210

    Do we know a ship date yet

    Do we know a ship date yet
  30. Replies
    687
    Views
    53,210

    So are they going to ship on the 7th

    So are they going to ship on the 7th
  31. Replies
    687
    Views
    53,210

    Thanks for the reply Jim what about the sensor...

    Thanks for the reply Jim what about the sensor mapping for several superheats off one suction pressure
  32. Replies
    687
    Views
    53,210

    Maby Jim can answer this question also what's the...

    Maby Jim can answer this question also what's the ship date look like I preorderd mine the first day from true tech
  33. Replies
    687
    Views
    53,210

    With the I connect will we be able to map...

    With the I connect will we be able to map mautible suction line temp sensors to 1 suction. Pressure so it can display several superheats all at one
  34. Replies
    687
    Views
    53,210

    So when is the release date

    So when is the release date
  35. Replies
    3
    Views
    681

    new job leak detector

    Has anybody one tryed this out supply house is pushing it big time
    http://www.jbind.com/products/Aurora-Refrigerant-Leak-Detector.aspx
  36. Replies
    17
    Views
    1,471

    more thin likely the forced compressor was...

    more thin likely the forced compressor was throwing off the controller next time you should check with a meter to see what is locking it ot
  37. Replies
    10
    Views
    891

    not on the rack unless its a new line up but on...

    not on the rack unless its a new line up but on splits and self contains yes I do
  38. Replies
    10
    Views
    891

    Just go to air gas a get a co2 regulator and a...

    Just go to air gas a get a co2 regulator and a flow meter that's where I got mine its a standers item for mig and tig welding and I have been purging with. Co2 and have no issues
  39. Replies
    5
    Views
    769

    what's they scale down there for a journeymen...

    what's they scale down there for a journeymen start up rack mechanic
  40. Replies
    5
    Views
    769

    union ?

    union ?
  41. Replies
    133
    Views
    8,878

    you could just torch the receiver to see if its...

    you could just torch the receiver to see if its full or just pull some gas in to a recovery cylinder and see when the glass flashes
  42. Replies
    3
    Views
    452

    how to properly a just h10 pm

    How do I properly set up my h10 in manual mode I have herd a least 3 different ways of doing so in manual mode dose the sensor adjustment that you need a screw driver to turn in the super rh corner...
  43. Replies
    15
    Views
    2,489

    we have been looking for orings for a wile the...

    we have been looking for orings for a wile the oring is very thin and square no orings I have tried have worked
  44. Replies
    15
    Views
    2,489

    target split condenser valve leaks

    has any one seen a huge number of target split condenser valves leaking I have found 21 in 2 months all are the dead winter condenser and all are sporlan oe35s1110 all of them have the large oring...
  45. Replies
    22
    Views
    1,707

    http://www.emersonclimate.com/europe/ProductDocume...

    http://www.emersonclimate.com/europe/ProductDocuments/AlcoLiterature/EN_PS3__35003.pdf

    I have a couple of older super plus racks running these the use to sell an adjustable one everything is...
  46. Replies
    1
    Views
    418

    you need to change the ip address of your lap go...

    you need to change the ip address of your lap go to network sharing center right click on Ethernet got to property's go down to tcip internet protocol right click go to property's change the ip and...
  47. Replies
    2
    Views
    648

    Those settings are very low

    Those settings are very low
  48. Replies
    6
    Views
    749

    I do it the way JP dose but some customers get...

    I do it the way JP dose but some customers get squimish when you back door in to there network . I also use a program called jump to control my lap top it works really good
  49. Replies
    43
    Views
    3,447

    you don't need to change the oil you need to find...

    you don't need to change the oil you need to find out why the oil is discolored and over heated its not oil like in your car it dose not just go bad a situation has to destroy it . I would definitely...
  50. Replies
    98
    Views
    9,733

    omg 41000 a year to run supermarket is insane I...

    omg 41000 a year to run supermarket is insane I would not touch that with a 10 foot poll
Results 1 to 50 of 198
Page 1 of 4 1 2 3 4

Related Forums

Plumbing Talks | Contractor MagazineThe place where Electrical professionals meet.
Quality Home Comfort Awards