Search:

Type: Posts; User: darkbeekeeper

Page 1 of 2 1 2

Search: Search took 0.01 seconds.

  1. Replies
    9
    Views
    1,727

    blue vac go to trutectools and use the discount...

    blue vac go to trutectools and use the discount for being a hvac talk member and i love the bluevac best one i have used
  2. Replies
    34
    Views
    4,012

    my State Farm Ins Agent set me up for about 100...

    my State Farm Ins Agent set me up for about 100 bucks a year i think it was for 5g's worth of coverage on tools
  3. Replies
    6
    Views
    995

    I have used black gold by Jb with no problems but...

    I have used black gold by Jb with no problems but i change the oil almost every job
  4. I think if i can get them to let me do a remote...

    I think if i can get them to let me do a remote desktop i can do most of the vav box stuff. i dont even have access to the programing part of the continuum yet so all i can do is make sure the vav's...
  5. we are have continuum and pinpoint. i will have...

    we are have continuum and pinpoint. i will have to buy any tools ill need up front whats a roamIO2 and software run to get me started
  6. I have a request in for that but its not...

    I have a request in for that but its not important to them yet im sure that will change in a week or two when the temps drop and a couple hundred complants come in for being cold
  7. Just got handed a andover controled night mare need help

    Ok guys i understand and do ok with hvac in need help with where to start with a building that uses andover with pinpoint and scx920's and tcx865 we have over 500 vav boxes that have been just hacked...
  8. Replies
    2
    Views
    641

    :cheers:

    :cheers:
  9. Replies
    12
    Views
    1,161

    Some of the cprs have screens in them that plug...

    Some of the cprs have screens in them that plug also. less spring tension higher suction check out sporlans web site they have service manuals for cprs
  10. That would be to easy of a fix

    That would be to easy of a fix
  11. Replies
    18
    Views
    3,027

    Watch this it has alot info becareful its a...

    Watch this it has alot info becareful its a youtube

    http://www.youtube.com/watch?v=JFu10K0pDbI&feature=youtu.be
  12. Replies
    6
    Views
    854

    post a link never heard of rd

    post a link never heard of rd
  13. Replies
    14
    Views
    3,397

    :cheers: we need to support trutech tools Jim...

    :cheers: we need to support trutech tools Jim Bergman and Bill Spohn spend alot of time working on helping techs with training and proper use of tools more than any other supply house i have seen. it...
  14. Replies
    65
    Views
    6,310

    :cheers: that sounds great put them on here as...

    :cheers: that sounds great put them on here as long as they dont get torn apart by the members
  15. :gah: i might have missed this do you even have...

    :gah:
    i might have missed this do you even have a epa cert if you dont dont even carry a jug of refrigerant in your service van what apprenticeship are you in
    all i can say is read read and read...
  16. Replies
    49
    Views
    6,131

    Sorry :hijacked: I have never heard of this...

    Sorry :hijacked:

    I have never heard of this some more info please
  17. Replies
    11
    Views
    1,314

    sounds like they need water regulating valves...

    sounds like they need water regulating valves check with city codes we can't use city water anymore
  18. Replies
    14
    Views
    3,144

    here is a good read there is some good info how...

    here is a good read there is some good info how to do quick check ect

    http://www.hoshizakiamerica.com/manuals/KM-1301S_H(3)_serv.pdf
  19. Replies
    14
    Views
    3,144

    Its hot the water temp is warm ambient air is...

    Its hot the water temp is warm ambient air is warm and with the 3 beeps your running close to the freeze timer 2 loads of ice hits a 60 min cycles it will trip, biggest problems with km's is they...
  20. i agree double check all your setting there they...

    i agree double check all your setting there they are off for 134a
  21. Replies
    12
    Views
    5,437

    if you scratch the lens lime will form on the...

    if you scratch the lens lime will form on the scratch faster use cleaner to keep it smooth so water runs off instead of hanging up on the build up and blocking them sooner
  22. Filters, blower running? i would say almost 90%...

    Filters, blower running?
    i would say almost 90% of my service calls have nothing to do with refrigerant charge i don't even take my gauges with me until i need them two rules KISS = keep it simple...
  23. Replies
    46
    Views
    4,254

    Wow :censored:

    Wow
    :censored:
  24. Have your building envelope checked more than...

    Have your building envelope checked more than likely you have a duct leakage problem,or to much outside air coming in or you just need better air filtration if it is bad have a blower test done along...
  25. Replies
    0
    Views
    681

    URS service company

    I was just wondering if anyone has worked for Urs they are a service company working at the Cat here in Il
  26. Replies
    4
    Views
    1,132

    have you checked these out yet how were they

    have you checked these out yet how were they
  27. Replies
    12
    Views
    1,264

    its that dam metric system pounds kilos oz grams

    its that dam metric system pounds kilos oz grams
  28. Replies
    13
    Views
    8,980

    its the cheaper Trane line i also heard Ameristar...

    its the cheaper Trane line i also heard Ameristar is new American Standard line which is all the same company
  29. Replies
    27
    Views
    2,258

    sounds like compressor valves make sure service...

    sounds like compressor valves make sure service vales are opened all the way and your gauge set manifold valves are closed
  30. You said school whats the room temp ac turned off...

    You said school whats the room temp ac turned off for the summer, clean the coil, get sh sc and i agree sounds like a restriction, careful on the wiegh in its a conversion from r12 to 401 "mp39" the...
  31. Replies
    3
    Views
    710

    Maytag Services, LLC Attn.: CAIRŪ Center P.O....

    Maytag Services, LLC
    Attn.: CAIRŪ Center
    P.O. Box 2370
    Cleveland, TN 37320-2370
    Web address: www.jennair.com
    Or call: 1-800-JENNAIR (1-800-536-6247).
    ...
  32. I aways set up beer coolers and hi traffic...

    I aways set up beer coolers and hi traffic walkins with heaters and time clocks just so i dont have so many calls for them leaving the door open or durning the high humidity in summer= frosted...
  33. Replies
    7
    Views
    1,148

    i have a ford E250 with bins it does everything i...

    i have a ford E250 with bins it does everything i want parts are cheap for it i get life time breaks from autozone change them out about every 40k or so i get about 200k before rust or what ever...
  34. can anyone watch the videos they come up private...

    can anyone watch the videos they come up private when i try view the link
  35. Replies
    11
    Views
    1,607

    I really like my testo 416

    I really like my testo 416
  36. looks great

    looks great
  37. Replies
    0
    Views
    470

    Ideas for android app

    Hay Guys give me your thoughts on want should be in a app for a Android phones and tablets I have been looking at a bunch of apps but they are to much to buy just to take a good look and the ones...
  38. Replies
    35
    Views
    6,222

    That is way cool I wonder how it would hold up

    That is way cool I wonder how it would hold up
  39. Works for me have you put the vac gauge to it yet?

    Works for me have you put the vac gauge to it yet?
  40. Replies
    13
    Views
    2,322

    I have a testo 327 love it

    I have a testo 327 love it
  41. Replies
    319
    Views
    25,676

    Testo hosed theirs down didnt hold it under water...

    Testo hosed theirs down didnt hold it under water but do you hammer nails with a level,its a precision testing device.

    http://www.youtube.com/watch?v=Du8P-OGtXNY&feature=player_detailpage
  42. Sticky: It worked fine for me i used it wih no problems....

    It worked fine for me i used it wih no problems. replaced the drier and schrader valves heres a link for it
    http://www2.dupont.com/ISCEON/en_US/assets/downloads/k23356_8_basic_steps.pdf
  43. Replies
    14
    Views
    2,867

    no co detectors in the home or on your...

    no co detectors in the home or on your tech?:whistle:
  44. Replies
    14
    Views
    1,512

    Those are really cool i hope that they are not...

    Those are really cool i hope that they are not 5bucks each :whistle:
  45. Replies
    2
    Views
    514

    Nice call Its people like you that make this site...

    Nice call Its people like you that make this site :cheers:
  46. Replies
    18
    Views
    1,604

    nice call I was thinking are they using a fan...

    nice call I was thinking are they using a fan control for cold weather
    i keep r11 around to clean up dye i hate that crap
  47. If you want to be able to answer your boss or the...

    If you want to be able to answer your boss or the customer you have to weigh it in. My jugs have writing all over them keeping track of whats in them, it's nice to know going on a call to work on a...
  48. Replies
    32
    Views
    1,910

    Sounds really cool but it sounds like they have...

    Sounds really cool but it sounds like they have had to many messing with it i have seen something like this to switch in summer and winter ended up making them all remotes and took out the water side...
  49. Replies
    13
    Views
    1,550

    Ill say it Thanks y7turbo:cheers: that was a good...

    Ill say it Thanks y7turbo:cheers: that was a good pdf and i kept a copy to help someone out later on down the road
  50. Replies
    6
    Views
    979

    IT skills will go a long way with the changes in...

    IT skills will go a long way with the changes in HVAC the problem here is you don't know if you like the HVAC part go talk to a HVAC contractor where you live maybe you can get a ride along for a day...
Results 1 to 50 of 81
Page 1 of 2 1 2
Comfortech Show Promo Image

Related Forums

Plumbing Talks | Contractor Magazine
Forums | Electrical Construction & Maintenance (EC&M) Magazine